• Title/Summary/Keyword: Muscle elasticity

Search Result 73, Processing Time 0.029 seconds

Reliability of Muscle Evaluation with a Tactile Sensor System (촉각센서를 이용한 근육평가의 신뢰도 조사)

  • Oh, Young-Rak;Lee, Dong-Ju;Kim, Sung-Hwan;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.337-344
    • /
    • 2005
  • A tactile sensor employs a piezoelectric element to detect contact frequency shifts and thereby measure the stiffness or softness of material such as tissue, which allows the sensor to be used in many fields of research for urology, cardiology, gynecology, sports medicine and caner detection and especially for cosmetics and skin care. In this study, reliability of the tactile sensor system was investigated with its manual application to the muscles susceptible to temporomandibular disorders. Stiffness and elasticity of anterior temporalis, masseter and trapezius muscles were calibrated bilaterally from 5 healthy men with an average of 24.5$\pm$0.94 years. The tactile sensor used in this study had a computer-controlled and motor-driven sensor unit which automatically pressed down on the skin surface over the muscles being measured and retracted, thereby providing the hysteresis curve. The slope of the tangent of the hysteresis curve (${\Delta}f/{\Delta}x$) is defined as stiffness of the muscle being measured and the distance between the two parts of the curve as its elasticity. To determine inter-examiner reliability, all the measurements were performed by the two examiners A and B, respectively and the same examination were repeated with an interval of 2 days for intra-examiner reliability. The results from this study demonstrated high reliability in measuring stiffness and elasticity of anterior temporalis, masseter and upper trapezius muscles using a tactile sensor system. It is suggested that the tactile sensor system can be a highly reproducible and effective instrument for quantitative evaluation of the muscle in head and neck region.

Effects of Oral Parafunction on the Stiffness and Elasticity in the Muscles of the Mastication and Facial Expression (구강악습관이 저작근 및 안면표정근의 경직도 및 탄성도에 미치는 영향)

  • Kim, Seung-Ki;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.1
    • /
    • pp.85-95
    • /
    • 2008
  • The purpose of this study was to evaluate the effects of oral habits on the muscles of mastication and facial expression by means of two parameters: muscle stiffness and elasticity. 10 healthy, fully-dentate male subjects in their twenties were selected for this study; all had normal Class I occlusal relationships. Muscle stiffness and elasticity were measured with a tactile sensor(Venustron, Axiom Co., JAPAN) while subjects were asked to relax and perform various parafunctional activities such unilateral clenching(biting the bite force recorder with a force of 50kg on each subject's preferred side), jaw thrusting and lip bracing. The following muscles were examined: temporalis anterior(Ta), masseter(Mm), frontalis(Fr), inferior orbicularis oculi(OOci), zygomaticus major(Zm), superior and inferior orbularis oris(OOrs and OOri) and mentalis(Mn). Paired t-test, Correlation Coefficients, ANOVA and Multiple Comparison t-tests were used for statistical analysis. Unilateral clenching was highly correlated with bilateral stiffness and elasticity of all the muscles tested. Mm was affected by all three oral habits; Ta was affected by unilateral clenching(p<0.05); Zm was affected by unilateral clenching and OOrs, OOri and Mn were most affected by lip bracing(p<0.05). This study indicates that not only the masticatory muscles but also the muscles of facial expression, mainly circumoral muscles, can be significantly influenced by parafunctional activities such as unilateral clenching and lip bracing.

The Visual Analysis of Myofascial Syndrome on Balance Posture (근육 근막 장애가 자세균형에 미치는 시각적 분석)

  • Park Young-Han
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.177-184
    • /
    • 1997
  • 1. The human body is the unification related to the powerful fascial network, I think. 2. Myofascial not only prevent and support the human body structure curdling but also keep the physical balance by dispersing traumatization properly. 3. Myofascial restriction will be developed into muscle deficiency and cause pains without releasing the muscle tension and the spasm. 4. Myofascial restriction affect and change the physical posture by losing the muscle elasticity and flexibility and by losing muscle supporting ability from gravitation. 5. The partial myofascial restriction affect the muscle and the adjoining joint supporting gravitation and cause the unbalance of the entire body.

  • PDF

Comparison to muscle activity of quadriceps femoris when apply a taping according to slope and speed during forward and backward walking on treadmill (트레드밀 전.후방 보행에서 경사도와 속도에 따른 넙다리네갈래근 테이핑 적용 시 근활성도 비교)

  • Kim, Byung-Kon;Lim, Mi-Sun;Seo, Hyun-Kyu
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.50-62
    • /
    • 2009
  • Purpose: to analyze and compare mucsle activity of Quadriceps femoris depending on the existence of taping while normal people walk forward and backward on treadmill when the slope and speed changes on treadmill. Method: Among 40 people who participated in this study, 20 experimenter who apply a taping walk forward and backward to 0%, 5%, 10% gradient per 2km/h and 4km/h using treadmill to give arbitrary walking behavior, 20 experimenter who doesn't apply a taping also walk forward and backward to 0%, 5%, 10% gradient per 2km/h and 4km/h using treadmill. To analyze muscle activity, We use an electromyography and Kinesio tape of good elasticity for obtained suffient effects in the experiment. Result: During backward walking in 2km/h, Vastus medialis and Vastus lateralis showed significant differences(p<0.05) when apply a taping. During backward walking in 2km/h, Vastus medialis and Rectus femoris, and Vastus lateralis all showed significant differences(p<0.05). During backward walking in 2km/h, Vastus medialis and Vastus lateralis showed significant differences in 10% gradient(p<0.05). During backward walking in 4km/h, Vastus medialis and Rectus femoris, and Vastus lateralis all showed significant differences(p<0.05). During backward walking in 4km/h, By the difference in slope, Vastus medialis and Vastus lateralis showed significant differences between 0% and 10% gradient(p<0.05). Conclusion: In comparison to muscle activity of Quadriceps femoris when apply a taping according to slope and speed during forward and backward walking on treadmill, when apply a taping and walk backward and 10% gradient on treadmill in 4km/h, maximum of muscle activity is shown.

  • PDF

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.

Studies on the Aging of Bovine Muscle at Adding the Proteolytic Enzyme -VII. Studies on the Histological Observation of Bovine Muscle Treated with Papain- (단백질(蛋白質) 분해효소(分解酵素) 첨가시(添加時) 우육(牛肉)의 숙성(夙成)에 관(關)한 연구(硏究) -VII. Papain 처리(處理) 우육(牛肉)의 조직학적(組織學的) 고찰(考察)-)

  • Yoon, Jung-Eui
    • Korean Journal of Food Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.271-276
    • /
    • 1977
  • Treating with step concentration of papain, round mucle of Korean cattle were cut in longitudinal and cross section and stained. Collagenous fibre and elastic fibre of its connective tissue were observed microscopically. The results were as follows: 1) In proportion to the increase of enzyme concentration amorphous bundle of collagenous fibre were loosed gradually and destroyed in the long run and besides the property of this fibre stained became remarkably weak. 2) Elastic fibre was paralleled to muscle fibre and in proportion to the increase of enzyme concentration, it was lost elasticity, loosed, straightened and broken remarkably to pieces. 3) Histological variation of collagenous fibre and elastic fibre treated with enzyme was more remarkable than control.

  • PDF

Studies on Histological Changes in Marine Foods during Processing and Storage 2. Changes in muscular tissue of the eel, Anguilla japonica, by freezing storage (수산식품의 가공 및 저장중의 조직학적 변화에 관한 연구 2. 뱀장어 동결저장중의 조직변화)

  • SONG Dae-Jin;LEE Eung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.3
    • /
    • pp.199-206
    • /
    • 1982
  • Histological changes occurred by freezing storage and subsequent thawing, and changes of muscle fiber after heating and drying of the eel (Anguilla japonica) were observed under microscope . The results are as follows : (1) After one month of freezing storage the muscular tissue produced considerable number of extracellular and intracellular ice crystals. The sample stored at the temperature of $-40^{\circ}C$ produced ice crystals inside the muscle cells while sample stored at $-20^{\circ}C$, outside. (2) No changes were observed in the hypodermic fat after thawing regardless of storage temperature, while insufficient recovering of muscle cells were detected in the muscular tissue. Muscular tissues which have been stored $-20^{\circ}C$ showed severe change in shape due to dehydration. (3) Microscopic observation on muscle homogenate showed loss of transparency due to free-zing, disfiguration and contraction by drying and water seperation, and elasticity by heating.

  • PDF

Effects of Wearing Spandex Pants on Impact Forces and Muscle Activities during Drop Landing (드롭 착지 동작 시 탄성 섬유 바지 착용이 충격력과 근육 활동에 미치는 영향)

  • Chae, Woen-Sik;Kang, Nyeon-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.603-610
    • /
    • 2009
  • The purpose of this study was to determine how spandex pants affect impact force and muscle activities in the lower extremity. Seven pairs of surface electrodes were attached to the right-hand side of the body. Paired t-test was performed to test if significant difference exist between two conditions(p< .05). The average IEMG activities in the TA, BF, and GM during the landing phase reduced significantly with spandex pants compared to regular pants. All peak IEMG activities except the RF in wearing spandex pants group were significantly greater than the corresponding values in wearing regular pants one. The greater muscle activity recorded in wearing spandex pants can be attributed to the greater motor unit recruitment needed to decelerate and stabilized their bodies. Impact force and loading rate were not significantly decreased with wearing spandex pants. Since the spandex pants used in this study were not custom-fit based on girth of each participants thigh and shank, compression and elasticity for the pants could not be optimized.

Usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases

  • Ogura, Ichiro;Nakahara, Ken;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.161-165
    • /
    • 2018
  • Purpose: To evaluate the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Materials and Methods: Ten patients with oral and maxillofacial diseases and 28 volunteers drawn from our student doctors were examined by shear wave elastography with a 14-MHz linear transducer using an Aplio 300 apparatus (Canon Medical Systems, Otawara, Japan). A statistical analysis of the shear elastic modulus(kPa) of healthy tissue (the sublingual gland, submandibular gland, anterior belly of the digastric muscle, and geniohyoid muscle) in the 28 volunteers was performed using 1-way repeated measures analysis of variance with the Tukey honest significant difference test. The maximum shear elastic modulus(kPa) of 8 patients with squamous cell carcinoma (SCC) and 2 patients with benign lesions was evaluated with the Mann-Whitney U test. The analysis used a 5% significance level. Results: The mean shear elastic modulus of the sublingual gland ($9.4{\pm}3.7kPa$) was lower than that of the geniohyoid muscle ($19.2{\pm}9.2kPa$, P=.000) and the anterior belly of the digastric muscle ($15.3{\pm}6.1kPa$, P=.004). The maximum shear elastic modulus of the SCCs($109.6{\pm}14.4kPa$) was higher than that of the benign lesions($46.4{\pm}26.8kPa$, P=.044). Conclusion: Our results demonstrated the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Shear wave elastography has the potential to be an effective technique for the objective and quantitative diagnosis of oral and maxillofacial diseases.

Effect of High-frequency Diathermy on Hamstring Tightness

  • Kim, Ye Jin;Park, Joo-Hee;Kim, Ji-hyun;Moon, Gyeong Ah;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.65-71
    • /
    • 2021
  • Background: The hamstring is a muscle that crosses two joints, that is the hip and knee, and its flexibility is an important indicator of physical health in its role in many activities of daily living such as sitting, walking, and running. Limited range of motion (ROM) due to hamstring tightness is strongly related to back pain and malfunction of the hip joint. High-frequency diathermy (HFD) therapy is known to be effective in relaxing the muscle and increasing ROM. Objects: To investigate the effects of HFD on active knee extension ROM and hamstring tone and stiffness in participants with hamstring tightness. Methods: Twenty-four participants with hamstring tightness were recruited, and the operational definition of hamstring tightness in this study was active knee extension ROM of below 160° at 90° hip flexion in the supine position. HFD was applied to the hamstring for 15 minutes using the WINBACK device. All participants were examined before and after the intervention, and the results were analyzed using a paired t-test. The outcome measures included knee extension ROM, the viscoelastic property of the hamstring, and peak torque for passive knee extension. Results: The active knee extension ROM significantly increased from 138.8° ± 9.9° (mean ± standard deviation) to 143.9° ± 10.4° after the intervention (p < 0.05), while viscoelastic property of the hamstring significantly decreased (p < 0.05). Also, the peak torque for knee extension significantly decreased (p < 0.05). Conclusion: Application of HFD for 15 minutes to tight hamstrings immediately improves the active ROM and reduces the tone, stiffness, and elasticity of the muscle. However, further experiments are required to examine the long-term effects of HFD on hamstring tightness including pain reduction, postural improvement around the pelvis and lower extremities, and enhanced functional movement.