• Title/Summary/Keyword: Multiple point load

Search Result 93, Processing Time 0.026 seconds

Optimal Coordination of Intermittent Distributed Generation with Probabilistic Power Flow

  • Xing, Haijun;Cheng, Haozhong;Zhang, Yi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2211-2220
    • /
    • 2015
  • This paper analyzes multiple active management (AM) techniques of active distribution network (ADN), and proposes an optimal coordination model of intermittent distributed generation (IDG) accommodation considering the timing characteristic of load and IDG. The objective of the model is to maximize the daily amount of IDG accommodation under the uncertainties of IDG and load. Various active management techniques such as IDG curtailment, on-load tap changer (OLTC) tap adjusting, voltage regulator (VR) tap adjusting, shunt capacitors compensation and so on are fully considered. Genetic algorithm and Primal-Dual Interior Point Method (PDIPM) is used for the model solving. Point estimate method is used to simulate the uncertainties. Different scenarios are selected for the IDG accommodation capability investigation under different active management schemes. Finally a modified IEEE 123 case is used to testify the proposed accommodation model, the results show that the active management can largely increase the IDG accommodation and penetration.

Design and Implementation of a Multi-Interface Access Point with Inter-interface Dynamic Load Balancing (인터페이스간 동적 부하 분배를 고려한 다중 인터페이스 액세스 포인트 설계 및 구현)

  • Kim, Tae-Keun;Seo, Hyung-Yoon;Kim, Jong-Deok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5A
    • /
    • pp.348-357
    • /
    • 2012
  • Recently, smartphone, notebook, PC and other supporting wireless LAN device have come into wide use. By increasing user that use wireless LAN device, wireless traffic also increased. If wireless traffic through one AP is increase, it causes throughput decrease. To solve this problem, wireless LAN service provider install more AP where overload occurred. But this is not enough. Because stations can't know AP's load factor, and APs do nothing for load balancing. In this paper, we propose Multi-Interface Access Point(MIAP) to solve this problem. MIAP operate same as multiple APs with multi-interface, and MIAP measure each interface's load periodically. If MIAP detect overloaded interface, MIAP transfer station from overloaded interface to under-loaded interface. We conducted an experiment for verifying existing problem, and we found this problem occurred. We plan an experiment scenario for a comparison between existing AP and MIAP, and excute these experiment. In the result, we show MIAP with load balancing can improve total throughput about 72% and stabilize delay jitter than existing AP.

Static Optimal Shapes of Tapered Beams with Constant Volume (일정체적 변단면 보의 정적 최적 단면)

  • Lee Tae-Eun;Kang Hee-Jong;Kim Kwon-Sik;Lee Byoung-Koo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.79-86
    • /
    • 2005
  • This paper deals with the static optimal shapes of simple beams which are subjected to a vertical point load. The area and second moment of inertia of the regular polygon cross-section of the tapered beams are determined, which have always same volume and same length for the parabolic taper. The differential equation governing the elastic curve is derived using the small deflection theory and solved numerically. By using the numerical results of deflections, rotations and bending stresses of such beams, the optimal shapes, namely, optimal section ratios, of the beams subjected to a single point load according to variation of load position parameters are determined and presented in the figures. Examples of the static optimal shapes for beams with a single load and multiple loads are reported. The design process of this study can be used directly for the minimum weight design of simple beams.

  • PDF

A Study on Fatigue Crack Growth Retardation Phenomena of Al 7075--T6 Alloy under Multiple overload(I) (다중 과하중에 의한 A1 7075-T6 합금의 피로균열 성장지연현상에 관한 연구)

  • 이택순;이유태
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.96-104
    • /
    • 1992
  • Aircraft structures and engineering structures are always subject to variable amplitude loads. Variable amplitude loads include some kind of loading history; for example, constant amplitude load, single peak overload and block overload etc. Crack growth under variable amplitude loading exhibits retardation effect. In this study, the 4 point bending fatigue test was performed by hydrolic servo fatigue testing machine on 7075-T6 Al-alloy. The retardation effect of overload ratio and numbers of overload cycle was quantitatively studied. 1) Change of retardation effect against increment of overload ratio is more evident when the multiple overload is applied than single overload is done. 2) The number of overload cycle is very important factor about the crack growth retardation effect when the overload ratio is more than 1.75; that is not when the overload ratio is less than 1.75. 3) Overload affected zone size increased gradually by increment of crack growth retardation effect. 4) Crack driving force is more greatly reduced when the crack tip branched off two direction than it sloped to one direction.

  • PDF

Approximate System Reliability Analysis Under Multiple Time Varying Loads (복합 하중하에서의 구조물 체계 신뢰도 해석)

  • 김상효
    • Computational Structural Engineering
    • /
    • v.1 no.2
    • /
    • pp.101-109
    • /
    • 1988
  • The evaluation of the system reliability is generally quite difficult and costly as the structure becomes large and complex, especially when it is subjected to multiple time varying loads, and for redundant structures which have many possible modes of failur, e.g., system collapse through the formation of plastic hinge mechanisms. In reality most loadings acting on the structures are random in intensity as well as in occurrence time and duration. To include the load variability in time, the loads are described in terms of stochastic processes. Based on a tri-modal upper bound, a point estimate for the system reliability has been developed for more accuracy without extensive computational effort. This tri-modal point estimate also ensures the continuity of the system reliability function, which is a necessary condition in many nonlinear programming techniques. In addition, the Load Coincidence method, by which the combined effect of time varying loads are taken into account, has been modified to suitable for cases with an always-on load.

  • PDF

Development and application of a vision-based displacement measurement system for structural health monitoring of civil structures

  • Lee, Jong Jae;Fukuda, Yoshio;Shinozuka, Masanobu;Cho, Soojin;Yun, Chung-Bang
    • Smart Structures and Systems
    • /
    • v.3 no.3
    • /
    • pp.373-384
    • /
    • 2007
  • For structural health monitoring (SHM) of civil infrastructures, displacement is a good descriptor of the structural behavior under all the potential disturbances. However, it is not easy to measure displacement of civil infrastructures, since the conventional sensors need a reference point, and inaccessibility to the reference point is sometimes caused by the geographic conditions, such as a highway or river under a bridge, which makes installation of measuring devices time-consuming and costly, if not impossible. To resolve this issue, a visionbased real-time displacement measurement system using digital image processing techniques is developed. The effectiveness of the proposed system was verified by comparing the load carrying capacities of a steel-plate girder bridge obtained from the conventional sensor and the present system. Further, to simultaneously measure multiple points, a synchronized vision-based system is developed using master/slave system with wireless data communication. For the purpose of verification, the measured displacement by a synchronized vision-based system was compared with the data measured by conventional contact-type sensors, linear variable differential transformers (LVDT) from a laboratory test.

A Performance Comparison of the Current Feedback Schemes with a New Single Current Sensor Technique for Single-Phase Full-Bridge Inverters

  • Choe, Jung-Muk;Lee, Young-Jin;Cho, Younghoon;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.621-630
    • /
    • 2016
  • In this paper, a single current sensor technique (SCST) is proposed for single-phase full-bridge inverters. The proposed SCST measures the currents of multiple branches at the same time, and reconstructs the average inductor, capacitor, and load current in a single switching cycle. Since all of the branches' current in the LC filter and the load are obtained using the SCST, both the inductor and the capacitor current feedback schemes can be selectively applied while taking advantages of each other. This paper also analyzes both of the current feedback schemes from the view point of the closed-loop output impedance. The proposed SCST and the analysis in this paper are verified through experiments on a 3kVA single-phase uninterruptible power supply (UPS).

A Stochastic Serving MPP Selection Method for Increasing the Efficiency of a Wireless Mesh Network (무선메쉬망에서 효율 증대를 위한 확률적 접속 MPP 선정 기법)

  • Park, Jae-Sung;Lim, Yu-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.6
    • /
    • pp.83-90
    • /
    • 2009
  • Since traffic is aggregated to a MPP that acts as an Internet gateway, if traffic load is not balanced among the MPPs in a WMN, the overall performance of a WMN becomes poor even though the total traffic load is far below the capacity of the WMN. Therefore, in this paper, we propose a stochastic load balancing scheme where each MP (Mesh Point) probabilistically selects its serving MPP according to the congestion levels of MPPs. Through extensive simulations using ns-2, we have verified that our scheme can stabilize a WMN fast when congestion occurs and reduce packet loss rate by distributing traffic load of a congested MPP to multiple MPPs in the inverse proportional to their congestion levels. Compared to queue-based load balancing scheme, our method can decrease network stabilization time by 34 seconds, and reduce packet loss rate by 7.6%. Since the proposed scheme can reduce network stabilization time by efficiently using network resource, it is expected to contribute to the reliable operation of a WMN.

Probabilistic Evaluation of Voltage Quality on Distribution System Containing Distributed Generation and Electric Vehicle Charging Load

  • CHEN, Wei;YAN, Hongqiang;PEI, Xiping
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1743-1753
    • /
    • 2017
  • Since there are multiple random variables in the probabilistic load flow (PLF) calculation of distribution system containing distributed generation (DG) and electric vehicle charging load (EVCL), a Monte Carlo method based on composite sampling method is put forward according to the existing simple random sampling Monte Carlo simulation method (SRS-MCSM) to perform probabilistic assessment analysis of voltage quality of distribution system containing DG and EVCL. This method considers not only the randomness of wind speed and light intensity as well as the uncertainty of basic load and EVCL, but also other stochastic disturbances, such as the failure rate of the transmission line. According to the different characteristics of random factors, different sampling methods are applied. Simulation results on IEEE9 bus system and IEEE34 bus system demonstrates the validity, accuracy, rapidity and practicability of the proposed method. In contrast to the SRS-MCSM, the proposed method is of higher computational efficiency and better simulation accuracy. The variation of nodal voltages for distribution system before and after connecting DG and EVCL is compared and analyzed, especially the voltage fluctuation of the grid-connected point of DG and EVCL.

A Consideration on 3-Phase Non-Loop, Multiple-Point Ground Method in 22.9[kV] CNCV Underground Cable Systems (22.9[kV] CNCV케이블 지중배전계통의 3상 비일괄 동심증성선 다중접지방식에 대한 이론적고찰)

  • Jeon, Myung-Su;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.85-93
    • /
    • 2008
  • In 22.9[kV]-y distribution systems, underground cables are provided with 3-wire loop multiple-point ground in which each coaxial-neutral line of the distribution cable lines(A, B, C phases) is 3-wire common grounded at every connecting section. In the underground cable distribution systems, circulating current flows in the coaxial-neutral lines and its magnitude amounts to about $40{\sim}50[%]$ load currents, even though loads are balanced. This paper presents a new ground method to overcome such a problem and a comprehensive analysis in tows of current capacity of power cables, induced voltage of cable sheath, and electromagnetic interference voltage from power cable lines.