• Title/Summary/Keyword: Multiple Units Control

Search Result 110, Processing Time 0.021 seconds

Study on Communication Interface of Multiple Smartphones for Unit Control in a PC (PC에서 유닛 제어를 위한 다중 스마트폰의 통신 인터페이스 연구)

  • Jung, Hahmin;Kim, Dong Hun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.6
    • /
    • pp.520-526
    • /
    • 2013
  • This study presents the unit control of a PC (Personal Computer) program using multiple smartphones based on ad hoc communication. A design of the data packet that multiple smartphones send to a computer, and a framework that manages and controls the unit in a computer after analyzing the data packet, are proposed. As a result, multiple users are able to control their own units using their smartphones while seeing the monitor connected to a computer. In other words, multiple users can share the same game in a computer or control their units embedded in a system using their smartphones. An experimental result shows that a racing game in a PC can be realized by the proposed communication interface, where four iPhones are used to control their units in a computer. Thus, the proposed framework can be effectively used for unit control in a PC using multiple smartphones.

Power System and Drive-Train for Omni-Directional Autonomous Mobile Robots with Multiple Energy Storage Units

  • Ghaderi, Ahmad;Nassiraei, Amir A.F;Sanada, Atsushi;Ishii, Kazuo;Godler, Ivan
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.291-300
    • /
    • 2008
  • In this paper power system and drive-train for omni-directional autonomous mobile robots with multiple energy storage units are presented. Because in proposed system, which is implemented in soccer robots, the ability of power flow control from of multiple separated energy storage units and speed control for each motor are combined, these robots can be derived by more than one power source. This capability, allow robot to diversify its energy source by employing hybrid power sources. In this research Lithium ion polymer batteries have been used for main and auxiliary energy storage units because of their high power and energy densities. And to protect them against deep discharge, over current and short circuit, a protection circuit was designed. The other parts of our robot power system are DC-DC converters and kicker circuit. The simulation and experimental results show proposed scheme and extracted equations are valid and energy management and speed control can be achieved properly using this method. The filed experiments show robot mobility functions to perform the requested motion is enough and it has a high maneuverability in the field.

A Study on Inventory Control Method for an Item with Stockkeeping Units (재고보유단위로 관리되는 제품의 재고관리 방법에 관한 연구)

  • Yoon, Seung-Chul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.1
    • /
    • pp.124-130
    • /
    • 2015
  • In many inventory situations, items for sales are generally stocked in a multiple of variations called stockkeeping units, such as size, color, style, and so on. For better management performance on sales items, proper and effective management is necessary for the stockkeeping units. In dealing with many items and those stockkeeping units, individual inventory analysis for each stockkeeping unit needs large amount of time or cost. Also the individual approach in inventory planning increases the demand variation of an item as the result by combining of demand variations of all stockkeeping units, accordingly the inventory turnover ratio and profitability are dropped down. This research suggests an effective method of systematic control of total stockkeeping units by generating from the total item basis, and shows how to reduce the safety stock and the average inventory with attaining a planned customer fill rate of the item and each stockkeeping units.

A Study on Deterioration Diagnostic Method for Electrical Wires of Electric Multiple Units (도시철도차량 전선에 대한 열화진단 방법 고찰)

  • Hong, Yong-Ki;Chung, Jong-Duk;Pyun, Jang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.680-687
    • /
    • 2009
  • Several kinds of Electrical Wires have been used in Electric Multiple Units(EMU) for the supply of electric power, supervision, and the propagation of control signals. These Electrical Wires must be inspected for safe and stable operation of EMU. The degradation diagnosis to estimate the integrity of Electrical Wires has recently been requested according to the long use of EMU. This paper describes on application of diagnosis method for EMU.

  • PDF

Optimal design of parallel noncontinuous units with feedstock/product storages (원료및 제품저장조를 포함하는 병렬 비연속 공정의 최적설계)

  • Yi, Gyeong-Beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.5
    • /
    • pp.532-541
    • /
    • 1997
  • This article derives an analytic solution to determine the optimal size of multiple noncontinuous process and storage units. The total cost to be minimized consists of the setup cost of noncontinuous processing units and the inventory holding cost of feedstock/product storages. A novel approach, which is called PSW(Periodic Square Wave) model, is applied to represent the material flow among non-continuous units and storages. PSW model presumes that the material flow between unit and storage is periodic square wave shaped. The resulting optimal unit size has similar characteristics with the classical economic lot sizing model such as EOQ(Economic Order Quantity) or EPQ(Economic Production Quantity) model in a sense that the unit size is determined as the balance between setup and inventory holding cost. However, the influence of inventory holding cost of PSW model is different from that of EOQ/EPQ model. EOQ/EPQ model includes only the product inventory holding cost but PSW model includes all inventory holding costs around the non-continuous unit with proportional contribution. PSW model is suitable for analyzing interlinked process-storage system. The optimal lot size of PSW model is smaller than that of EOQ/EPQ model. This is quitea remarkable result considering that the EOQ/EPQ model has been is widely used since last half century.

  • PDF

Coordinated Voltage Control Scheme for Multi-Terminal Low-Voltage DC Distribution System

  • Trinh, Phi Hai;Chung, Il-Yop;Kim, Taehoon;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1459-1473
    • /
    • 2018
  • This paper focuses on voltage control schemes for multi-terminal low-voltage direct current (LVDC) distribution systems. In a multi-terminal LVDC distribution system, there can be multiple AC/DC converters that connect the LVDC distribution system to the AC grids. This configuration can provide enhanced reliability, grid-supporting functionality, and higher efficiency. The main applications of multi-terminal LVDC distribution systems include flexible power exchange between multiple power grids and integration of distributed energy resources (DERs) using DC voltages such as photovoltaics (PVs) and battery energy storage systems (BESSs). In multi-terminal LVDC distribution systems, voltage regulation is one of the most important issues for maintaining the electric power balance between demand and supply and providing high power quality to end customers. This paper focuses on a voltage control method for multi-terminal LVDC distribution system that can efficiently coordinate multiple control units, such as AC/DC converters, PVs and BESSs. In this paper, a control hierarchy is defined for undervoltage (UV) and overvoltage (OV) problems in LVDC distribution systems based on the control priority between the control units. This paper also proposes methods to determine accurate control commands for AC/DC converters and DERs. By using the proposed method, we can effectively maintain the line voltages in multi-terminal LVDC distribution systems in the normal range. The performance of the proposed voltage control method is evaluated by case studies.

Multiple Units Control of Boiler and Refrigerator in HVAC System (공조용(空調用) 열원기기(熱源機器)의 대수분리(臺數分離) 제어(制御)에 관한 연구(硏究))

  • Sohn, J.Y.;Kim, H.S.;Ahn, B.W.;Shin, Y.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • The purpose of this paper is to provide an efficient method of operating and designing HVAC systems for reasonable energy consumption in building. Accroding to the conditions of indoor temperature and humidity, and the methods of dividing and grouping the capacity of boiler and refrigerator, the amount of their annual energy consumptions is simulated by using an energy analysis program which is developed in this paper, and opatimal design methods of HVAC system are suggested as well.

  • PDF

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

A memory management scheme for parallel viterbi algorithm with multiple add-compare-select modules (다중의 Add-compare-select 모듈을 갖는 병렬 비터비 알고리즘의 메모리 관리 방법)

  • 지현순;박동선;송상섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.8
    • /
    • pp.2077-2089
    • /
    • 1996
  • In this paper, a memory organization and its control method are proposed for the implementation of parallel Virterbi decoders. The design is mainly focused on lowering the hardware complexity of a parallel Viterbi decoder which is to reduce the decoding speed. The memories requeired in a Viterbi decoder are the SMM(State Metric Memory) and the TBM(Traceback Memory);the SMM for storing the path metrics of states and the TBM for storing the survial path information. A general parallel Viterbi decoder for high datarate usually consists of multiple ACS (Add-Compare-Select) units and their corresponding memeory modules.for parallel ACS units, SMMs and TBMs are partitioned into smaller independent pairs of memory modules which are separately interleaved to provide the maximum processing speed. In this design SMMs are controlled with addrss generators which can simultaneously compute addresses of the new path metrics. A bit shuffle technique is employed to provide a parallel access to the TBMs to store the survivor path informations from multiple ACS modules.

  • PDF

Factors Influencing Level of Awareness and Compliance with Vancomycin-Resistant Enterococcus Infection Control among Nurses in Intensive Care Units (중환자실 간호사의 반코마이신 내성 장구균 감염관리에 대한 인지도, 이행도 및 관련요인)

  • Park, Young-Mi;Park, Hyoung-Sook;Park, Kyung-Yeon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.15 no.4
    • /
    • pp.531-538
    • /
    • 2008
  • Purpose: The purpose of this study was to identify factors influencing Vancomycin-resistant enterococcus infection control among nurses in intensive care units. Method: Data were collected from August 15 to October 14, 2007 from 188 nurses working in intensive care units. The nurses answered a 26 item-questionnaire, which included management of the cohort (14 items), hand washing (6 items) and management of the environment (6 items). Descriptive statistics, t or F test, ANOVA, and multiple regression analysis were used with SPSS PC+ 14.0 to analyze the data. Results: The participant's level of awareness of Vancomycin-resistant enterococcus infection control was 3.87; that of compliance was 3.74. Significant factors influencing the level of compliance with Vancomycin-resistant enterococcus infection control were'the level of the awareness' and 'the type of intensive care unit'. These two variables accounted for 21.0% of variance for compliance with the Vancomycin-resistant enterococcus infection control among the participants. Conclusion: In order to develop a strategy to increase the compliance with Vancomycin-resistant enterococcus infection control, it is necessary to be concerned about 'the level of the awareness', 'the type of intensive care unit;', and 'experiences of caring for patients with Vancomycin-resistant enterococcus'.

  • PDF