• Title/Summary/Keyword: Multilevel Method

Search Result 294, Processing Time 0.021 seconds

Study on the Transient EHL Fluid Film for the Dynamic Contact Behaviors between Cam and Follower with Multigrid Multilevel Method (다중격자 다중차원 기법을 응용한 캠과 종동물의 비정상 상태의 유막특성 연구)

  • 장시열
    • Tribology and Lubricants
    • /
    • v.20 no.3
    • /
    • pp.132-139
    • /
    • 2004
  • Many researches about the contacts between cam and follower have investigated EHL film thickness either without dynamic loading effect or only with curve fitting formula such as Dowson-Hamrock's, because including squeeze film effect makes it hard to obtain convergence and stability of computation. Therefore, inaccurate information about minimum film thickness without dynamic loading condition causes inappropriate design of cam profiles and wrong selection of cam and follower materials. In this work, computation tools both for kinematics and dynamics of valve train system of push-rod type and for fluid film thickness with elastic deformation on the basis of dynamic loading condition with multigrid multi-level method is developed. The computational results of minimum film thickness with the respects of both static and dynamic loading conditions are compared for the contact of flat follower over the entire cycle.

Level Selection Algorithm with Fixed Sampling Frequency for Modular Multilevel Converter (고정 샘플링 주파수에서의 모듈형 멀티레벨 컨버터 레벨 선택 알고리즘)

  • Kim, Chan-Ki;Park, Chang-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.415-423
    • /
    • 2018
  • This study uses a level selection algorithm with fixed sampling frequency for modular multilevel converter (MMC) systems. Theoretically, the proposed method increases the level infinitely while the sampling time remains the same. The proposed method called cluster stream buffer (CSB) consists of several clusters, wherein each cluster is composed of 32 submodules that depend on the level of the submodules in the MMC system. To increase the level of the MMC system, additional clusters are used, and the sampling time between clusters is determined from the sampling time between levels needed for utilizing the entire level from the MMC system. This method is crucial in the control of MMC-type HVDC systems because it improves scalability and precision.

Multilevel Threshold Selection Method Based on Gaussian-Type Finite Mixture Distributions (가우시안형 유한 혼합 분포에 기반한 다중 임계값 결정법)

  • Seo, Suk-T.;Lee, In-K.;Jeong, Hye-C.;Kwon, Soon-H.
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.6
    • /
    • pp.725-730
    • /
    • 2007
  • Gray-level histogram-based threshold selection methods such as Otsu's method, Huang and Wang's method, and etc. have been widely used for the threshold selection in image processing. They are simple and effective, but take too much time to determine the optimal multilevel threshold values as the number of thresholds are increased. In this paper, we measure correlation between gray-levels by using the Gaussian function and define a Gaussian-type finite mixture distribution which is combination of the Gaussian distribution function with the gray-level histogram, and propose a fast and effective threshold selection method using it. We show the effectiveness of the proposed through experimental results applied it to three images and the efficiency though comparison of the computational complexity of the proposed with that of Otsu's method.

A Stable Multilevel Partitioning Algorithm for VLSI Circuit Designs Using Adaptive Connectivity Threshold (가변적인 연결도 임계치 설정에 의한 대규모 집적회로 설계에서의 안정적인 다단 분할 방법)

  • 임창경;정정화
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.69-77
    • /
    • 1998
  • This paper presents a new efficient and stable multilevel partitioning algorithm for VLSI circuit design. The performance of multilevel partitioning algorithms that are proposed to enhance the performance of previous iterative-improvement partitioning algorithms for large scale circuits, depend on choice of construction methods for partition hierarchy. As the most of previous multilevel partitioning algorithms forces experimental constraints on the process of hierarchy construction, the stability of their performances goes down. The lack of stability causes the large variation of partition results during multiple runs. In this paper, we minimize the use of experimental constraints and propose a new method for constructing partition hierarchy. The proposed method clusters the cells with the connection status of the circuit. After constructing the partition hierarchy, a partition improvement algorithm, HYIP$^{[11]}$ using hybrid bucket structure, unclusters the hierachy to get partition results. The experimental results on ACM/SIGDA benchmark circuits show improvement up to 10-40% in minimum outsize over the previous algorithm $^{[3] [4] [5] [8] [10]}$. Also our technique outperforms ML$^{[10]}$ represented multilevel partition method by about 5% and 20% for minimum and average custsize, respectively. In addition, the results of our algorithm with 10 runs are better than ML algorithm with 100 runs.

  • PDF

Quick Diagnosis of Short Circuit Faults in Cascaded H-Bridge Multilevel Inverters using FPGA

  • Ouni, Saeed;Zolghadri, Mohammad Reza;Rodriguez, Jose;Shahbazi, Mahmoud;Oraee, Hashem;Lezana, Pablo;Schmeisser, Andres Ulloa
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.56-66
    • /
    • 2017
  • Fast and accurate fault detection is the primary step and one of the most important tasks in fault tolerant converters. In this paper, a fast and simple method is proposed to detect and diagnosis the faulty cell in a cascaded H-bridge multilevel inverter under a short circuit fault. In this method, the reference voltage is calculated using switching control pulses and DC-Link voltages. The comparison result of the output voltage and the reference voltage is used in conjunction with active cell pulses to detect the faulty cell. To achieve this goal, the cell which is active when the Fault signal turns to "0" is detected as the faulty cell. Furthermore, consideration of generating the active cell pulses is completely described. Since the main advantage of this method is its simplicity, it can be easily implemented in a programmable digital device. Experimental results obtained with an 11-level inverter prototype confirm the effectiveness of the proposed fault detection technique. In addition, they show that the diagnosis method is unaffected by variations of the modulation index.

A Study on Multilevel Communication Drive of Full-Duplex Method with Security (보안성을 겸비한 전이중방식의 다중레벨 통신드라이브에 관한 연구)

  • Cho, Su-Eog;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.41-48
    • /
    • 2020
  • Currently, the industry uses MODBUS communication method using RS485 as a communication method used when constructing distributed equipment and networks. However, this method has a rather good transmission and reception distance, but has a disadvantage of being a half-duplex communication method. Therefore, there is a great need for a full-duplex communication method that can simultaneously transmit and receive two-wire communications. Therefore, in this paper, we propose a new communication hardware equipment that can implement full-duplex communication method by communication signal level to overcome the disadvantage of communication speed. The proposed communication hardware is a structure that can transmit and receive at the same time on the same communication line in two equipments communicating in a two-wire system. The characteristic of this communication hardware is that the transmitter generates two-level signal for data transmission, but the receiver generates three-level electric signal according to the status of the transmission data generated by the receiver. The data transmission signal information of the receiver is present at the same time. Therefore, the receiving side can analyze the received signal based on the information on the current transmission signal and can analyze the signal only in the two communicating devices, so it can be seen that the communication security is very excellent.

Design and Control Method for Sub-module DC Voltage Ripple of HVDC-MMC

  • Gwon, Jin-Su;Park, Jung-Woo;Kang, Dea-Wook;Kim, Sungshin
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.921-930
    • /
    • 2016
  • This paper proposes a design and control method for a high-voltage direction current modular multilevel converter (HVDC-MMC) considering the capacitor voltage ripple of the submodule (SM). The capacitor voltage ripple consists of the line frequency and double-line-frequency components. The double line- frequency component does not fluctuate according to the active power, whereas the line-frequency component is highly influenced by the grid-side voltage and current. If the grid voltage drops, a conventional converter increases the current to maintain the active power. A grid voltage drops, current increment, or both occur with a capacitor voltage ripple higher than the limit value. In order to reliably control an MMC within a limit value, the SM capacitor should be designed on the basis of the capacitor voltage ripple. In this paper, the capacitor voltage ripple according to the grid voltage and current are analyzed, and the proposed control method includes a current limitation method considering the capacitor voltage ripple. The proposed design and control method are verified through simulation using PSCAD/EMTDC.

A Fault-Tolerant Control Strategy for Cascaded H-Bridge Multilevel Rectifiers

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Schanen, Jean-Luc;Khakbazan-Fard, Mahboubeh
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • Reliability is an important issue in cascaded H-bridge converters (CHB converters) because they use a high number of power semiconductors. A faulty power cell in a CHB converter can potentially lead to expensive downtime and great losses on the consumer side. With a fault-tolerant control strategy, operation can continue with the undamaged cells; thus increasing the reliability of the system. In this paper, the operating principles and the control method for a CHB multilevel rectifier are introduced. The influence of various faults on the CHB converter is investigated. The method of fault diagnosis and the bypassing of failed cells are explained. A fault-tolerant protection strategy is proposed to achieve redundancy in the CHB rectifier. The redundant H-bridge concept helps to deal with device failures and to increase system reliability. Simulation results verify the performance of the proposed strategy.

Estimation of Data Distribution Using Multidimensional Dynamic File Organization (다차원 동적 화일 구조를 이용한 데이타 분포의 추정)

  • Kim, Sang-Wook
    • Journal of Industrial Technology
    • /
    • v.15
    • /
    • pp.41-50
    • /
    • 1995
  • This paper presents a technique for estimating distribution of data stored in a database. This technique is very useful for accurate selectivity estimation, which is essential in query optimization and physical database design. To maintain data distribution, we employ the directory of the multilevel grid file, a multidimensional dynamic file organization. The major advantage of our technique is that data distribution information is maintained dynamically in the multilevel grid file. In contrast, other static methods such as the histogram method use static date structures, which requires periodic restructuring. Furthermore, we propose a method for keeping the abstract information of data distribution in main memory. This is advantageous in the situation where the size of main memory is not sufficient. Finally, We also suggest formulas for calculating selectivies of various queries based on our data distribution information.

  • PDF

An Application of Proportional-Resonant Controller in MMC-HVDC System under Unbalanced Voltage Conditions

  • Quach, Ngoc-Thinh;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1746-1752
    • /
    • 2014
  • This paper presents an application of proportional-resonant (PR) current controllers in modular multilevel converter-high voltage direct current (MMC-HVDC) system under unbalanced voltage conditions. The ac currents are transformed and controlled in the stationary reference frame (${\alpha}{\beta}$-frame). Thus, the complex analysis of the positive and negative sequence components in the synchronous rotating reference frame (dq-frame) is not necessary. With this control method, the ac currents are kept balanced and the dc-link voltage is constant under the unbalanced voltage fault conditions. The simulation results based on a detailed PSCAD/EMTDC model confirm the effectiveness of the proposed control method.