• Title/Summary/Keyword: Multi-switching

Search Result 707, Processing Time 0.021 seconds

The Optimal Number of Dividing and Connecting Per Feeder in Korea Distribution System (국내 배편계통의 최적 연계(안))

  • Jo, Nam-Hun;Kim, Geon-Jung;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.7
    • /
    • pp.349-361
    • /
    • 2002
  • Occasionally, equipment in a distribution system fails due to damage from weather, vandalism, or other causes. Failures and unexpected events do not always occur as and where expected. Therefore, a good contingency plan, multi-zone or otherwise, provides flexibility by locating switches at various strategic locations so that parts of a feeder can be picked up in the event of line outages at various places. It is possible to create feeder system layout that achieve remarkable contingency support economics, even as their normal peak loading levels approach thermal capacity, by utilizing six, seven, or even nine switchable zones per feeder. But many switchable zones per feeder are of questionable practicality and effectiveness, because of the complexity and time required for the switching operation. In practice, a zonal scheme with between three and four zones will usually provide complete contingency backup for all feeders. Line switches have both capital and maintenance costs, the planning for multi-zonal schemes is considerably more difficult than or loop or single-zone systems, and the required switching operations required during contingencies take more time. But multi-zonal schemes are used because these costs come to far less than the cost of additional capacity required for loop or single-zone. In this paper, we present the optimal number of switchable zones per feeder in Kora distribution system.

Harmonic Optimization Techniques in Multi-Level Voltage-Source Inverter with Unequal DC Sources

  • Aghdam, M. Ghasem Hosseini;Fathi, S. Hamid;Gharehpetian, Gevorg B.
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.171-180
    • /
    • 2008
  • One of the major problems in electric power quality is the harmonic contents. There are several methods of indicating the quantity of harmonic contents. The most widely used measure is the total harmonic distortion (THD). Various switching techniques have been used in static converters to reduce the output harmonic content. This paper presents and compares the two harmonic optimization techniques, known as optimal minimization of the total harmonic distortion (OMTHD) technique and optimized harmonic stepped-waveform (OHSW) technique used in multi-level inverters with unequal dc sources. Both techniques are very effective and efficient for improving the quality of the inverter output voltage. First, we describe briefly the cascaded H-bridge multi-level inverter structure. Then, we present the switching algorithm for the inverter based on OHSW and OMTHD techniques. Finally, the results obtained for the two techniques are analyzed and compared. The results verify the effectiveness of the both techniques in multi-level voltage-source inverter with non-equal dc sources, clarifying the advantages of each technique.

3-Phase Transformer Isolated Multi-level Inverter Using Common Arm (공통암을 이용한 3상 변압기 절연 멀티레벨 인버터)

  • Song, Sung-Geun;Park, Sung-Jun;Kim, Dong-Ok;Lim, Young-Cheol;Kim, Kwang-Heon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.149-156
    • /
    • 2007
  • The number of transformer and the size of transformer in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm, in this paper. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching loss can be reduced. Finally, We tested multi-level inverter to clarify electric circuit md reasonableness through Matlab simulation and experiment by using prototype inverter.

Multi-level Converter for Low EMI and High Quality Output Voltage (저 EMI 및 고품질 출력전압을 위한 멀티레벨 컨버터)

  • Lee, Sang-Hun;Lee, Min-Jung;Park, Sung-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2015-2021
    • /
    • 2008
  • Recently, with the growth of photovoltaic system, many researchers and companies have concerned about the multi-level inverter which has an efficiency of boosting voltage. In this paper a novel structure of multi-level converter for reducing ripple of output voltage is proposed. In the proposed converter Buck converters are connected in series to generate the output voltage and the ripple of output voltage can be reduced compared with the exiting Buck converter. Especially when outputting lower output voltage the number of acting switching elements is less and the result of ripple reducing is more obvious. This paper implements a multi-level switching function based on the FPGA.

IMT-2000 Packet Data Processing Method utilizing MPLS (MPLS망을 적용한 IMT2000 시스템에서의 패킷 데이터 처리 절차)

  • Yu, Jae-Pil;Kim, Gi-Cheon;Lee, Yun-Ju
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.11S
    • /
    • pp.3190-3198
    • /
    • 1999
  • Because of the rapid growth of the mobile communication, the need for the mobile internet access has grown up as well. since the current mobile communication network, however, is optimized for a voice communication system, which exclusively occupies a channel for a given time, it is not suitable for variable rate packet data. In order to support the mobile internet access, it is essential do design a reasonable packet switching network which supports the mobility. Since mobile packet network has longer latency, high speed switching and QoS are required to meet the user's requirements. In this paper, we suggest an resonable way to construct a network and its operation procedures utilizing GPRS(General Packet Radio Service) network and MPLS(Multi Protocol Label Switching) to provide a high speed switching and QoS mobile internet access. GPRS is used as a network which supports the mobility and MPLS guarantees the QoS and high speed IP protocol transmission based on the ATM switching technology.

  • PDF

HIERARCHICAL SWITCHING CONTROL OF LONGITUDINAL ACCELERATION WITH LARGE UNCERTAINTIES

  • Gao, F.;Li, K.Q.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.351-359
    • /
    • 2007
  • In this study, a hierarchical switching control scheme based on robust control theory is proposed for tracking control of vehicle longitudinal acceleration in the presence of large uncertainties. A model set consisting of four multiplicative-uncertainty models is set up, and its corresponding controller set is designed by the LMI approach, which can ensures the robust performance of the closed loop system under arbitray switching. Based on the model set and the controller set, a switching index function by estimating the system gain of the uncertainties between the plant and the nominal model is designed to determine when and which controller should be switched into the closed loop. After theoretical analyses, experiments have also been carried out to validate the proposed control algorithm. The results show that the control system has good performance of robust stability and tracking ability in the presence of large uncertainties. The response time is smaller than 1.5s and the max tracking error is about $0.05\;m/S^2$ with the step input.

A Probabilistic Model for the Comparison of Various ATM Switching System (ATM교환 시스템의 성능 분석을 위한 확률 모형)

  • Kim, J.S.;Yoon, B.S.;Lie, C.H.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.1
    • /
    • pp.47-59
    • /
    • 1993
  • Recently, Broadband ISDN(B-ISDN) has received increased attention as a communication architecture which can support multimedia applications. Also, Asynchronous Transfer Mode(ATM) is considered as a promising technique to transfer and switch various kinds of media, such as telephone speech, data and motion video. Comparisons among a variety of ATM switching systems which have already been proposed will provide quite useful information for the new ATM switching system design. To facilitate the comparison, we introduce the design requirements and classification criteria for the ATM switch, and propose a performance analysis model for the Banyan network which is the basic switching fabric of most multi-stage ATM switching systems. The model is based on the standard discrete-time Markov chain analysis and can be conveniently used for extensive Banyan network analysis. The computational results are also presented.

  • PDF

The Effects of Multi-Modality on the Use of Smart Phones

  • Lee, Gaeun;Kim, Seongmin;Choe, Jaeho;Jung, Eui Seung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.3
    • /
    • pp.241-253
    • /
    • 2014
  • Objective: The objective of this study was to examine multi-modal interaction effects of input-mode switching on the use of smart phones. Background: Multi-modal is considered as an efficient alternative for input and output of information in mobile environments. However, there are various limitations in current mobile UI (User Interface) system that overlooks the transition between different modes or the usability of a combination of multi modal uses. Method: A pre-survey determined five representative tasks from smart phone tasks by their functions. The first experiment involved the use of a uni-mode for five single tasks; the second experiment involved the use of a multi-mode for three dual tasks. The dependent variables were user preference and task completion time. The independent variable in the first experiment was the type of modes (i.e., Touch, Pen, or Voice) while the variable in the second experiment was the type of tasks (i.e., internet searching, subway map, memo, gallery, and application store). Results: In the first experiment, there was no difference between the uses of pen and touch devices. However, a specific mode type was preferred depending on the functional characteristics of the tasks. In the second experiment, analysis of results showed that user preference depended on the order and combination of modes. Even with the transition of modes, users preferred the use of multi-modes including voice. Conclusion: The order of combination of modes may affect the usability of multi-modes. Therefore, when designing a multi-modal system, the fact that there are frequent transitions between various mobile contents in different modes should be properly considered. Application: It may be utilized as a user-centered design guideline for mobile multi modal UI system.

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

MAC Aware Multi-Channel Routing Protocol for Multi-Interface Ad-Hoc Wireless Networks (다중-인터페이스 애드-혹 무선 네트워크를 위한 MAC 인식 다중-채널 라우팅 프로토콜)

  • Lim, Hunju;Joung, Sookyoung;Lee, Sungwha;Park, Inkap
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.249-258
    • /
    • 2013
  • In multi-hop ad hoc networks, multi-interface multi-channel architecture is being noticing as methodology to improve the effective bandwidth and end-to-end throughput, But since existing routing metrics designed for networks based on single-interface exactly can not reflects the nature of networks based on multi-interface multi-channel, we are not expected the effect of throughput improvement. there had been proposal of MCR that discover high throughput by using metrics such as channel diversity and interface switching cost. however, MCR have an problem that is degraded it's performance in congested networks, because it not reflects the impact of traffic load. in this paper, we propose MAMCR metric, which select high throughput paths under congested conditions by combination MCR with channel access time metric, and conform it's the effect of performance improvement by ns-2 simulation.