• 제목/요약/키워드: Multi-story building

검색결과 170건 처리시간 0.028초

Seismic reliability of precast concrete frame with masonry infill wall

  • Mahdi Adibi;Roozbeh Talebkhah;Hamid Farrokh Ghatte
    • Earthquakes and Structures
    • /
    • 제24권2호
    • /
    • pp.141-153
    • /
    • 2023
  • The presented paper considers infill masonry walls' influence on the seismic reliability of precast concrete frames. The recent Bojnord earthquake on May 13th, 2017 in Iran (MW 5.4) illustrated that the infill masonry walls play a crucial role in the damage extent and life safety issues of inhabitants in the precast concrete buildings. The incremental dynamic analysis (IDA) approach was used to determine the fragility curves of the represented damaged precast frame. Then, by integrating site hazard and structural fragilities, the seismic reliability of the represented precast frame was evaluated in different damage limit states. Additionally, the static pushover analysis (SPA) approach was used to assess the seismic performance assessment of the precast frame. Bare and infilled frames were modeled as 2D frames employing the OpenSees software platform. The multi-strut macro-model method was employed for infill masonry simulation. Also, a relatively efficient and straightforward nonlinear model was used to simulate the nonlinear behavior of the precast beam-column joint. The outputs show that consideration of the masonry infilled wall effect in all spans of the structural frame leads to a decrease in the possibility of exceedance of specified damage limit states in the structures. In addition, variation of hazard curves for buildings with and without consideration of infilled walls leads to a decrease in the reliability of the building's frames with masonry infilled walls. Furthermore, the lack of infill walls in the first story significantly affects the precast concrete frame's seismic reliability and performance.

고유진동수 조절이 가능한 액체댐퍼의 건물응답 제어실험 (Experimental Verification of a Liquid Damper with Changeable Natural Frequency for Building Response Control)

  • 김동익;민경원;박지훈;김재건;황규석;길용식
    • 한국전산구조공학회논문집
    • /
    • 제25권4호
    • /
    • pp.323-330
    • /
    • 2012
  • 본 연구진은 최근 U자 형태인 액체댐퍼의 수직관을 다수의 셀(사각 기둥)로 나누어 셀 상부를 개폐함에 따라 다양한 고유진동수를 쉽게 재현하는 새로운 멀티셀 액체댐퍼를 제시하였다. 이러한 댐퍼를 1층 건물 모형에 설치하여 진동대 실험을 수행하여 건물응답이 감소되는 것을 검증하였다. 64층의 풍응답인 가속도를 제어할 수 있도록 댐퍼를 설계하기 위하여 건물을 1자유도계로 축소하였다. 가속도 기반 상사비인 1/20를 적용하여 1층 건물 모형과 새로운 댐퍼를 제작하였다. 설계 진동수인 0.65Hz가 구현되도록 모형건물의 질량과 강성을 쉽게 조절할 수 있도록 탈부착식으로 제작하였다. 모형건물은 중량을 부담하는 질량부와 하부에 스프링과 LM guide가 설치된 구동부로 나누어서 제작되었다. 18개의 셀을 가지는 액체댐퍼를 제작하여 고유진동수 조절 범위가 0.65Hz~0.81Hz인 것을 파악하였다. 대형 진동대에 설치한 모형건물의 일방향 가진을 통하여 모형의 응답을 측정하고 모형상부에 멀티셀 액체댐퍼가 설치되었을 경우 모형의 응답을 측정하여 비교하였다. 진동대 가속도를 입력과 모형건물의 가속도를 출력으로 하는 전달함수를 통해 결과를 나타내었다. 예상한 바와 같이 멀티셀 액체댐퍼의 고유진동수를 건물의 진동수에 동조시켰을 경우 건물의 가속도 응답이 감소함을 알 수 있었다.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

도시열섬 적응능력 제고를 위한 옥상녹화 중점지역 선정 방안 (Selection of Green Roof Initiative Zone for Improving Adaptation Capability against Urban Heat Island)

  • 박은진
    • 한국환경복원기술학회지
    • /
    • 제17권1호
    • /
    • pp.135-146
    • /
    • 2014
  • The improvement of adaptation capability against heat island (ACHI) by greening buildings is considered as an important measure to cope with a climate change. This study aimed to select the most appropriate zones for green roof initiative in case study sites, Bucheon, Anyang, and Suwon Cities and to investigate the characteristics of buildings for greening to improve ACHI. Relative ACHI for each lot was estimated from 0 to -9, assuming that it decreases with the distance from green space and waterbody. Low adaptation capabilities were mostly shown in the old urban blocks with dense low-rise buildings and lack of green space. Three blocks with the lowest ACHIs were chosen as a green roof initiative zone in each city. They are largely residential areas including low-rise buildings such as single, multi-household houses, townhouses, 5 or lower story apartments and few are industrial areas crowded with small factory buildings. The areas of building roof available for greening are 8.8% within the selected zones in Bucheon City, 5.3% in Anyang City, and 4.9% in Suwon City. As it were, 25.2~41.7% of the roof top areas are available for greening in these zones. It means that roof top areas of $25,000{\sim}120,000m^2$ can be used for greening within the selected zones of $0.64{\sim}1.65km^2$ to improve ACHI. The approach and results of the study are significant to provide a logical basis and information on location, scale, effect, and target figure of greening as a measure to cope with climate change.

Structural performance and SWOT analysis of multi-story buildings of lightweight reinforced concrete comprising local waste materials

  • Walid A., Al-Kutti;A.B.M. Saiful, Islam;Zaheer Abbas, Kazmi;Mahmoud, Sodangi;Fahad, Anwar;Muhammad, Nasir;Muhammad Arif Aziz, Ahmed;Khalid Saqer, Alotaibi
    • Earthquakes and Structures
    • /
    • 제23권6호
    • /
    • pp.493-502
    • /
    • 2022
  • In recent decades, infrastructural development has exploded, particularly in the coastal region of Saudi Arabia. The rising demand of most consumed aggregate in construction can be effectively compensated by the alternative material like scoria which lavishly exists in the western region. Scoria is characterized as lightweight aggregate beneficially used to develop lightweight concrete (LWC) - a potential alternative of normal weight concrete (NWC) ensuring reduction in the structural element's size, increase in building height, comparatively lighter foundation, etc. Hence, the goal of this study is to incorporate scoria-based structural lightweight concrete and evaluate its impact on superstructure and foundation design beside contributing to the economy of construction. Fresh, mechanical, and rheological properties of the novel LWC have been investigated. The structural analyses employ the NWC as well as LWC based structures under seismic and wind loadings. The commercial finite element package - ETABS was employed to find out the change in structural responses and foundations. The cost estimation and SWOT analysis for superstructure and foundation have also been carried out. It was revealed that the developed LWC enabled a more flexible structural design. Notable reduction in the steel and concrete prices of LWC might be possible in the low-rise building. It is postulated that the cost-effective and eco-friendly LWC will promote the usage of scoria as an effective alternative in Saudi Arabia and GCC countries for structurally viable LWC construction.

도시생태계 현황파악 및 자연성 증진 방안 -서울시 강서구를 사례로- (Ecosystem Structure and Improvement of Naturalness in Urban Area -In the Case of Kangseo-gu in Seoul-)

  • 이수동;이경재
    • 한국조경학회지
    • /
    • 제32권3호
    • /
    • pp.1-17
    • /
    • 2004
  • The focus of this study is the promotion of green area volumes and their naturalness, water circulation system, decline of entropy, creation of biological habitats and linkage of separated urban green space. Re-presentative urban biotope survey sites were categorized as urban biotope, semi-natural biotope, and natural forest. In the urban biotope, a residential biotope was constructed near the Han river and in mountain areas. The green-area ratio at the housing complex was about 25%. GVZ(Grunvolumenzahl) was 0.35m$^3$/m$^2$ at the 5∼10-story housing complex, and 1.53m$^3$/m$^2$ over the 11-story. As for the green-area structure of the housing complex, canopy layer, understory layer, and shrub layer were not differentiated and the green-area volume was not high enough. The green-area ratio of school areas as a public area biotope was 5∼20%. GVZ was 1.12m$^3$/m$^2$ at Myungduk High School, and 1.78m$^3$/m$^2$ at Jeonggok Elementary School. In order to convert the urban biotope into an ecological area, green areas around the buildings should be connected to urban buffer green areas, and multi-layer structures should be established with natural plant species. In the semi-natural biotope, neighbor parks were created park in the vicinity of the natural forests. GVZ was 0.28m$^3$/m$^2$, and plantation was established with single layer structure and was definitely insufficient for the area. The urban buffer green areas have been established in strip corridors with the width of 20∼123m. In those areas, GVZ was 0.16∼0.27m$^3$/m$^2$ and had a deficient canopy layer, understory layer, and shrub layer. Soil conditions were not favorable for tree growth. In the natural biotope, GVZ of the plantation was 1.03∼1.5m$^3$/m$^2$ but the high crown closure of this area reduces the chance of species change and succession. GVZ of natural forest was 2.53∼2.57m$^3$/m$^2$. It is desirable to plant diverse plants and the natural forest should be succeeded by broad-leaf deciduous tree species. To improve the value of biotope at Kangseo-Gu, building height needs to be limited to reduce the environmental deterioration in the city. In order to maintain the water circulation system, water-permeable material is recommened when the urban surface areas are paved. The establishment of a water circulation system will improve ground water levels, soil moisture, water quality, and habitats. In order to improve biological diversity, it is desirable to have multi-layer structures in urban green areas with native species.

지진격리장치를 적용한 복층구조파이핑 시스템의 내진성능평가 (Seismic Performance Evaluation of Multi-Story Piping Systems using Triple Friction Pendulum Bearing)

  • 류용희;주부석;손호영
    • 한국재난정보학회 논문집
    • /
    • 제14권4호
    • /
    • pp.450-457
    • /
    • 2018
  • 연구목적: 2016년 9월 경주 이후 구조물 및 비구조물의 지진 안전성 및 내진성능에 관한 문제가 이슈화 되고 있으며, 특히 배관 시스템의 경우 구조요소 보다 지진 발생시 내진성능에 있어서 취약하다고 볼 수 있다. 스프링클러 배관 시스템과 같은 비구조적 구성요소의 손상으로 인해 지진 발생 및 이후에 상당한 경제적 손실이나 생명 손실을 초래 할 수 있다. 연구방법: 본 연구는 Triple Friction Pendulum Bearings (TPBs)을 설치한 건물 배관 시스템을 이용한 소방 배관 시스템의 내진성능평가를 제시한다. Kobe, Kocaeli, GyeongJu 지진을 고려하여 지반 운동의 불확실성을 고려하였다. 연구결과: 빌딩 시스템과 파이핑 시스템의 첫 번째 모드는 각각 약 5.8Hz와 약 2.742Hz로 나타났으며, 또한 TPBs 시스템이 적용된 배관 시스템의 최대 변위는 Kobe, Kocaeli 및 GyeongJu 지진의 경우 각각 49%, 14.4%, 21.5%가 감소한 것으로 나타났다. 결론: 따라서 건물 배관 시스템에서 지진 격리 시스템을 사용하면 지진이 심할 때 TPB가 없는 일반적으로 설치된 걸물 배관 시스템보다 지진 위험을 줄일 수 있다.

가중 다목적성을 고려한 구조물 응답 제어용 TMD의 RSM 기반 실용적 최적 설계 (RSM-based Practical Optimum Design of TMD for Control of Structural Response Considering Weighted Multiple Objectives)

  • 도정윤;국성오;김두기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권6호
    • /
    • pp.113-125
    • /
    • 2017
  • 본 연구는 전산실험을 통해 중규모 건물에 설치한 수동형 TMD의 매개변수에 대한 가중 다목적 최적화 설계를 다루고 있다. MATLAB으로 수치 시뮬레이션 코드를 작성함으로써 지진하중에 대한 동적응답을 파악하였으며 중심합성계획법과 반응표면법으로 구성한 전산실험을 기반으로 하는 가중 다목적 최적화 기법을 적용하여 TMD의 최적 동조 매개변수를 찾고자 하였다. 본 연구에서는 10층 건물을 대상으로 El Centro를 벤치마크 지진으로 가진하여 반응모델을 생성하고, AHP를 이용하여 반응변수 사이의 상대적 중요도를 산출한 후 가중다목적최적화 설계를 실시하였다. 본 연구의 방법으로 최적화된 매개변수를 가진 TMD는 지진 응답을 효과적으로 저감하였다. El Centro 지진이 작용하는 경우 RSM 기반 가중 다목적 최적설계방법으로 최적화한 TMD의 진동수 응답과 최상층 평균제곱변위는 비제진시보다 각각 31.6%와 82.3% 향상되었고, 모든 적용 지진에서 기존 설계법보다 동등 또는 이상의 성능을 가진 것으로 확인되었다.

매입형(슬림플로어) 합성보의 휨성능 평가 -춤이 깊은 데크플레이트와 비대칭 H형강 철골보- (Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate)

  • 허병욱;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권2호통권69호
    • /
    • pp.235-245
    • /
    • 2004
  • 현재 합성 구조가 사용성 측면에서 경제적이고 작업성이 좋으며, 시공상의 편의성 등의 장점이 있다는 것은 일반화된 사실이지만, 자체의 춤이 깊기 때문에 철골조 건물에 적용하기에 여러 가지 비효율적 측면이 있다. 따라서 본 연구에서는 합성보의 전체 춤을 절감할 수 있도록 철골보의 춤내에 콘크리트를 삽입하여 일체화함으로써 철골조 고층건물에서 층고를 최소화 할 수 있는 이른바 "슬림플로어" 공법에 대한 연구를 수행하였다. 본 연구는 콘크리트에 매입된 비대칭 철골보를 가지는 부분 합성 슬림플로어 시스템의 휨거동에 관한 것이다. 총 8개의 실대형 실험체를 철골보 춤, 전단연결 유무, 슬래브 유효폭, 및 콘크리트 토핑두께 별로 제작하여 실험을 수행하였다. 실험결과, 별도의 전단연결재를 설치하지 않은 실험체는 자체가 가지고 있는 기계적 화학적 부착응력으로 인해 완전합성보에 비해서 $0.53{\sim}0.95$의 전단합성비를 나타내었다.

Chaotic particle swarm optimization in optimal active control of shear buildings

  • Gharebaghi, Saeed Asil;Zangooeia, Ehsan
    • Structural Engineering and Mechanics
    • /
    • 제61권3호
    • /
    • pp.347-357
    • /
    • 2017
  • The applications of active control is being more popular nowadays. Several control algorithms have been developed to determine optimum control force. In this paper, a Chaotic Particle Swarm Optimization (CPSO) technique, based on Logistic map, is used to compute the optimum control force of active tendon system. A chaotic exploration is used to search the solution space for optimum control force. The response control of Multi-Degree of Freedom (MDOF) shear buildings, equipped with active tendons, is introduced as an optimization problem, based on Instantaneous Optimal Active Control algorithm. Three MDOFs are simulated in this paper. Two examples out of three, which have been previously controlled using Lattice type Probabilistic Neural Network (LPNN) and Block Pulse Functions (BPFs), are taken from prior works in order to compare the efficiency of the current method. In the present study, a maximum allowable value of control force is added to the original problem. Later, a twenty-story shear building, as the third and more realistic example, is considered and controlled. Besides, the required Central Processing Unit (CPU) time of CPSO control algorithm is investigated. Although the CPU time of LPNN and BPFs methods of prior works is not available, the results show that a full state measurement is necessary, especially when there are more than three control devices. The results show that CPSO algorithm has a good performance, especially in the presence of the cut-off limit of tendon force; therefore, can widely be used in the field of optimum active control of actual buildings.