• Title/Summary/Keyword: Multi-modulation

Search Result 560, Processing Time 0.033 seconds

Performance Analysis of the M-PPAM DS-UWB Communication systems (M-PPAM DS-UWB 통신시스템의 성능해석)

  • Cho, Kyung-Ryong;Park, Jang-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1656-1662
    • /
    • 2005
  • This paper introduces M-PPAM(M-ary Pulse Position and Amplitude Modulation) architecture, combined PPM(Pulse Position Modulation) with PAM(Pulse Amplitude Modulation). Since M-PPAM can transmit several bits using one pulse, it is mon effective than PPM or PAM. Also, to obtain the same data transmission rate with PPM or PAM, M-PPAM can use a long pulse repetition period. This method will be able to use in the multi-path fading environment such as indoor condition. To accomodate multiple users, direct sequence technique is used. This paper has provided the modeling method of the M-PPAM DS-UWB receiver covering multi-user interference(MUI) with the Standard Gaussian Approximation under Gaussian channel. The performance of the receiver is simulated.

A Study on the Load Frequency Control of Power System Using an Optimal Modulation Controller (최적 변조제어기를 이용한 전력시스템의 부하주파수 제어에 관한 연구)

  • 정형환;허동렬;정문규;주석민;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.299-306
    • /
    • 2002
  • The load frequency control(LFC) of power system is one of important subjects in view of system operation and control. That is, even though the rapid load disturbances are applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow ones of each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation are given, the unstable phenomena of power systems can be often brought out because of the large frequency deviation and the unsuppressible power line one. So, an optimal modulation controller for UC of multi-area power system is designed by a recursive algorithm that determines the state weighting matrix Q of a linear quadratic performance criterion. The optimal modulation controller is based on optimal control and can obtain the exact dynamic response of the UC of multi-area power system in the time domain. The performances of the resultant optimal modulation control, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the UC of multi-area power system in the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbance of stepwise load changes, the superiorities of the proposed optimal modulation controller in robustness and stability were proved.

Analysis and Optimization of the Cross-Modulation Noise in Multi-Band CDMA Handset (멀티밴드 CDMA 단말기에서 Cross-Modulation 잡음에 의한 영향 분석 및 최적화)

  • Kwack, Jun-Ho;Joung, In-Gun;You, Chee-Hwan;You, Jung-Ho;Kim, Hak-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1A
    • /
    • pp.1-8
    • /
    • 2007
  • In this paper, we have derived the Noise-Equation to determine the level of cross-modulation noise that is required for designing multi-band CDMA handset from IS-98 standard. From this Noise-Equation, also we were able to determine each component's specification and forecast the performance(or margin) of designing handset. In conclusion, we have designed and implemented the multi-band CDMA handset of Qualcomm's Zero-IF structure and verified validity of the Noise-Equation. In result, we have got the result of ${\pm}0.5dB$ error between Noise-Equation and actual measurement. Therefore, this paper will give a guideline for design of the Multi-Band CDMA handset.

A Unified Carrier Based PWM Method In Multilevel Inverters

  • Nho Nguyen Van;Youn Myung Joong
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.142-150
    • /
    • 2005
  • This paper presents a systematic approach to study the carrier based pulse width modulation (PWM) techniques applied to diode-clamped and cascade multilevel inverters by using multi-modulating patterns. This method is based on the description of controllable redundant parameters in the modulating signals. A unified mathematical formulation is presented for carrier based PWM methods, which obtains outputs similar to the corresponding space vector PWM. A full and separate control of the fundamental voltage, vector redundancies and phase redundancies can be obtained in the carrier based PWM. In this paper, the proposed PWM method and corresponding algorithm for generating multi-modulating signals will be formulated and demonstrated by our simulations.

1 Bit/Pixel Modulation Codes for Multi-Level Holographic Data Storage System (멀티레벨 홀로그래픽 데이터 저장장치를 위한 1비트/픽셀 변조부호)

  • Jeong, Seongkwon;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1667-1671
    • /
    • 2015
  • Multi-level holographic data storage is a candidate for the next generation data storage system, since it can store more than one bit per pixel. It is possible to increase the number of codewords if the number of levels is increased, and the code with an appropriate selection of codewords can also increase the minimum distance. In this paper, we propose three multi-level modulation codes of the code rate 1 bit/pixel and compare the performance according to the minimum distance. The result shows that the code with small number of levels is better than that of large number of levels because it is hard to detect threshold value.

Multi-Sequence Signaling Based Asynchronous Trellis-Coded DS/CDMA System (다중 시퀀스 시그날링에 기초한 비동기 트레리스 부호화 DS/CDMA 시스템)

  • Sangho Choe
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3A
    • /
    • pp.248-256
    • /
    • 2004
  • Woerner had suggested an asynchronous trellis-coded DS/CDMA system based on a multi-sequence signaling, biorthogonal sequence, which is superior to single sequence signaling, such as M-ary PSK, due to their better cross-correlation properties. This paper analyzes and compares system performance between OPSM, a recently-presented multi-sequence signaling scheme, and biorthogonal sequence signaling. Interuser interference moments of the two schemes are derived and compared which verifies that OPSM, having smaller signature sequences per symbol than biorthogonal signaling, reduces cross-correlation. Numerical results compare the power and spectral efficiency of asynchronous trellis-coded DS/CDMA systems based on multi-sequence signaling.

A Multicoded-PPM Scheme for High Data Rate UWB Communication Systems

  • lung, Sung-Yoon;Park, Dong-Jo
    • Journal of Communications and Networks
    • /
    • v.11 no.3
    • /
    • pp.271-278
    • /
    • 2009
  • A new modulation scheme called multicoded-pulse position modulation (MC-PPM) is proposed for an ultrawideband (UWB) impulse radio communication system. The multicoded signal is generated by using several orthogonal codes for transmitting data simultaneously. Then, each multi-level value of the multicoded signal is converted to pulse position which results in not only an improved data rate, but also a processing gain in reception, delivering the power-efficient benefit of PPM and guaranteeing the low pulse energy for UWB systems. We notice that the modulation of multi-level values of the multicoded signal to pulse position is more efficient in terms of achievable data rate than the modulation of transmitting data based on other PPM schemes within given bandwidth and pulse energy. Therefore, as a performance measure, we focus on the achievable data rate (link capacity) of the proposed scheme and analyze it theoretically. Through simulation, we compare the link capacity of the MC-PPM scheme and other PPM schemes, such as M -ary PPM and multiple PPM. With the fixed bandwidth and same pulse energy condition, the UWB system based on the proposed MC-PPM scheme shows good link capacity and an increased data rate as L increases, which is contrary to other PPM schemes.

New Pre-charging Method for Modular Multi-level Converter operated in Nearest Level Control Modulation (근사 계단 제어 변조로 동작하는 모듈형 멀티 레벨 컨버터를 위한 새로운 초기 충전 기법)

  • Kim, Kyo-Min;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.129-130
    • /
    • 2016
  • 본 논문에서는 근사 계단 제어 변조(Nearest Level Control Modulation)로 동작하는 모듈형 멀티레벨 컨버터(Modular Multi level Converter)에서 충전 회로나 반송파(Carrier)없이 초기 충전(Pre-charging)하는 새로운 방식을 제안하였다. 이의 성능을 검증하기 위해 PSCAD/EMTDC 소프트웨어를 통해 암(Arm)당 12개의 서브모듈(Sub-Module)로 구성된 3상 10kVA 모듈형 멀티레벨 컨버터를 구현 및 시뮬레이션을 수행하였다.

  • PDF

A Novel SVPWM Strategy Considering DC-link Balancing for a Multi-level Voltage Source Inverter

  • Kim, Rae-Young;Lee, Yo-Han;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.159-164
    • /
    • 1998
  • This paper proposes a SVPWM (space vector pulse width modulation) strategy for a multi-level voltage source inverter. This strategy is easily implemented as SPWM (sinusoidal pulse width modulation) and has the same DC-link voltage utilization as general SVPWM. The method to keep the voltage balancing of DC-link also is proposed by the analysis model of DC-link voltage fluctuation. The usefulness of the proposed SVPWM is verified through the simulation.

  • PDF

Capacity Modulation of a Multi-Type Heat Pump System Using PID Control (PID 제어를 이용한 멀티형 열펌프의 용량조절)

  • 정대성;김민성;김민수;이원용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.446-475
    • /
    • 2000
  • Performance of a water-to-water multi-type heat pump system using R22 has been experimentally investigated. Total refrigerant flow rate was adjusted with a variable speed compressor and the refrigerant flow rate for two indoor units were controlled by electronic expansion valves. Evaporator outlet pressure of refrigerant and indoor unit outlet temperatures of secondary fluid were selected as controlled variables. Experiments were carried out for both cooling and heating modes using PID control method. Results show that the multi-type heat pump system can be adequately controlled by keeping control gains at certain levels for various operating conditions.

  • PDF