• 제목/요약/키워드: Multi-degree-of-freedom structure

검색결과 102건 처리시간 0.024초

다자유도 구동 스피리컬 모터의 토크리플 저감 설계에 관한 연구 (A Study on Torque Ripple Reduction of the Multi-degree of Freedom Operated Spherical Motor)

  • 강동우;이주
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1541-1543
    • /
    • 2013
  • This paper presents a spherical motor which can control in multi-degree of freedom operation. The spherical motor has been researched by many types of structure. Thhis paper shows a spherical shaped airgap and surfaced permanent magnets. Especially, The motor consists of dual rotor cores. Unlike a cylindrical motor, the spherical motor design can be considered with azimuth direction on spherical coordinates. Therefore the permanent magnet surfaced on the rotor need to be designed optimally in order to generate a sinusoidal magnetic flux density in the airgap. This paper presents results of optimal design for reducing torque ripple of the multi-degree of freedom spherical motor.

Seismic reliability analysis of structures based on cumulative damage failure mechanism

  • Liu, Qiang;Wang, Miaofang
    • Earthquakes and Structures
    • /
    • 제18권4호
    • /
    • pp.519-526
    • /
    • 2020
  • Non-stationary random seismic response and reliability of multi-degree of freedom hysteretic structure system are studied based on the cumulative damage failure mechanism. First, dynamic Eqs. of multi-degree of freedom hysteretic structure system under earthquake action are established. Secondly, the random seismic response of a multi-degree freedom hysteretic structure system is investigated by the combination of virtual excitation and precise integration. Finally, according to the damage state level of structural, the different damage state probability of high-rise frame structure is calculated based on the boundary value of the cumulative damage index in the seismic intensity earthquake area. The results show that under the same earthquake intensity and the same floor quality and stiffness, the lower the floor is, the greater the damage probability of the building structure is; if the structural floor stiffness changes abruptly, the weak layer will be formed, and the cumulative damage probability will be the largest, and the reliability index will be relatively small. Meanwhile, with the increase of fortification intensity, the reliability of three-level structure fortification is also significantly reduced. This method can solve the problem of non-stationary random seismic response and reliability of high-rise buildings, and it has high efficiency and practicability. It is instructive for structural performance design and estimating the age of the structure.

Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation

  • Jiang, Guoping;Tao, Weijun
    • Structural Engineering and Mechanics
    • /
    • 제51권4호
    • /
    • pp.643-650
    • /
    • 2014
  • A chaotic vibration isolation system is designed according to the chaotic vibration theory in this paper. The strong nonlinearity is generated by the system. Line spectra in the radiated noise maybe easily detected caused by marine vessels. It is Important to reduce the line spectra by improving the acoustic stealth of marine vessels. A multi-degree-freedom (MDF) nonlinear vibration isolation system (NVIS) system is setup by the experiment and finite element method. The model is established with finite element method. The results show that the behavior of the device gradually varies from period bifurcation into chaotic state and the line spectrum is changed from single spectral structure into broadband spectral structure. It is concluded that chaotic vibration isolation is preferable contrasted on line spectra isolation.

다층 층상 구조물의 진동제어에 관한 연구 (I) (A Study on Vibration Control of Multi-layer Structure(I))

  • 정해종;변정환;양주호
    • 수산해양기술연구
    • /
    • 제33권2호
    • /
    • pp.141-148
    • /
    • 1997
  • This paper is concerned with the vibration control of multi-layer structure for ultra-tall buildings and main tower of large bridge etc. We have modeled the multi-layer structure with the distributed mass system as the lumped mass system of two-degree-of-freedom structure and made experimental equipment. The LQ optimal control theory is applied to the design of the control system. The designed control system is simulated by computer. As a result, the LQ regulator showed good vibration control performance with impact excitation.

  • PDF

다 자유도 운동장치를 이용한 세장구조물의 진동제어 연구 (A Study of Vibration Control of a Slender Structure Using a Multi-Degree-of-Freedom Manipulator)

  • 김낙인;이종원
    • 대한기계학회논문집A
    • /
    • 제25권8호
    • /
    • pp.1227-1234
    • /
    • 2001
  • A multi d.o.f robotic manipulator is considered for multi-axis vibration control of a slender structure, using the concept of the flow source based vibration control. In order not to cause the motion saturation of the manipulator system, a hybrid dynamics associated with the flexible and desired manipulator error dynamics is also modeled as the control object. It is numerically shown that the flexible vibrations and the base motions of a test structure can be effectively controlled with the proposed hybrid dynamics.

다축 절삭가공용으로의 육관절 산업용 로봇의 적용평가 (Application Estimate of 6 Degree of Freedom Industrial Robot for Multi-Axes Cutting Machine)

  • 정선환;최성대;권현규;최은환
    • 한국기계가공학회지
    • /
    • 제2권4호
    • /
    • pp.33-39
    • /
    • 2003
  • The stiffness of multi-articulated industrial robots is very weak, because their structure is an articulated type with some links and joints. Thus it is known that cutting processes for metals are not accepted in machine shop well, but they have a lot of merits for cutting processes, for example, drilling, tapping, and engraving etc, because of the characteristics of their high degree of freedom. The temptation of cutting aluminium was carried out to investigate the feasibility and the limitations or constraints for cutting metals on them. First the mode shapes of 6 degree of freedom welding robot were taken and analysed, and next the cutting processes were practically carried out on it. The results of study were found out to show the feasibility of cutting processes at drilling under 6mm of tool diameter, as well as to have some limitations and constraints, for examples, feed rate, depth of cut and cutting force etc.

  • PDF

Estimation of earthquake induced story hysteretic energy of multi-Story buildings

  • Wang, Feng;Zhang, Ning;Huang, Zhiyu
    • Earthquakes and Structures
    • /
    • 제11권1호
    • /
    • pp.165-178
    • /
    • 2016
  • The goal of energy-based seismic design is to obtain a structural design with a higher energy dissipation capacity than the energy dissipation demands incurred under earthquake motions. Accurate estimation of the story hysteretic energy demand of a multi-story structure is the key to meeting this goal. Based on the assumption of a mode-equivalent single-degree-of-freedom system, the energy equilibrium relationship of a multi-story structure under seismic action is transformed into that of a multi-mode analysis of several single degree-of-freedom systems. A simplified equation for the estimation of the story seismic hysteretic energy demand was then derived according to the story shear force and deformation of multi-story buildings, and the deformation and energy relationships between the mode-equivalent single-degree-of-freedom system and the original structure. Sites were categorized into three types based on soil hardness, namely, hard soil, intermediate hard (soft) soil, and soft soil. For each site type, a 5-story and 10-story reinforced concrete frame structure were designed and employed as calculation examples. Fifty-six earthquake acceleration records were used as horizontal excitations to validate the accuracy of the proposed method. The results verify the following. (1) The distribution of seismic hysteretic energy along the stories demonstrate a degree of regularity. (2) For the low rise buildings, use of only the first mode shape provides reasonably accurate results, whereas, for the medium or high rise buildings, several mode shapes should be included and superposed to achieve high precision. (3) The estimated hysteretic energy distribution of bottom stories tends to be underestimated, which should be modified in actual applications.

Decentralized Active Vibration Control Systems for Multi Degree of Freedom Structures

  • Wang, Jiankun;Iwai, Zenta;Deng, Mingcong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.230-233
    • /
    • 1999
  • This paper is concerned with the design method of a de-centralized linear control system and its application to vibration control of multi degree of freedom structures. The method is based on the partial model matching on frequency domain by minimizing the relative model error functions between the diagonal elements of the open loop transfer function matrix of the control system and these of the reference model. The method is examined and evaluated by both simulation and experiment of a multi degree of freedom structure(MDFS).

  • PDF

일반 시설물의 지반-구조물 상호작용 해석 기준에 대한 고찰 (Overview on Standards for Soil-Structure Interaction Analysis used in Design of Infrastructure)

  • 김현욱;하정곤;김동수;주광호
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.227-236
    • /
    • 2017
  • This study reviews concepts, theories and formulas included in standards on soil-structure interaction and also shows practical example of application for engineers. Real structures are 3 dimensional and multi degree of freedom but they are often idealized to single degree of freedom for convenience. In this study, detailed procedures to calculate soil spring constants and damping coefficients and method to model soil-structure system are explained. Additionally, case studies to judge fixed base condition and evaluation of applicability of simple analysis method based on response spectra are performed.

LQ 형 $H_{\infty}$ 제어기법에 의한 다층 구조물의 진동제어 (A Vibration Control of Multi-layer Structure by LQ Type $H_{\infty}$ Control Theory)

  • 양주호;정해종;김창화;변정환;심성효
    • 동력기계공학회지
    • /
    • 제2권2호
    • /
    • pp.41-46
    • /
    • 1998
  • This paper presents the vibration control for the two degree-of-freedom which is a reduced model of multi-layer structure. This reduced model is designed for the first and second order resonance in the low frequency domain where the disturbance such as the earth quake has the large energy. And a designed controller using the LQ type $H_{\infty}$ control theory shows the good performance for the impulse disturbance through the experimental results and the simulation results respectively.

  • PDF