A Feasibility Study on the Cold Hollow Cathode Gas Ion Source for Multi-Aperture Focused Ion Beam System (다개구 이온빔 가공장치용 냉음극 방식의 가스 이온원의 가능성 평가에 관한 연구)

  • Choi, Sung-Chang;Kang, In-Cheol;Han, Jae-Kil;Kim, Tae-Gon;Min, Byung-Kwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.383-388
    • /
    • 2011
  • The cold hollow cathode gas ion source is under development for multi aperture focused ion beam (FIB) system. In this paper, we describe the cold hollow cathode ion source design and the general ion source performance using Ar gas. The glow discharge characteristics and the ion beam current density at various operation conditions are investigated. This ion source can generate maximum ion beam current density of approximately 120 mA/$cm^2$ at ion beam potential of 10 kV. In order to effectively transport the energetic ions generated from the ion source to the multi-aperture focused ion beam(FIB) system, the einzel lens system for ion beam focusing is designed and evaluated. The ions ejected from the ion source can be forced to move near parallel to the beam axis by adjusting the potentials of the einzel lenses.

A Study on Runoff Water Reduction Effects According to Shapes of Formation of Artificial Soil Green Area in Multi-Housing Complex (공동주택단지 내 인공지반 녹지조성 형태에 따른 우수유출 저감효과)

  • Nam, Mi A;Jang, Dae Hee;Kim, Hyeon Soo
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • This study aims to analyze, by forming an experimental area of artificial soil green area that is of equal scale and analyzing the characteristics of runoff water in accordance with the cross-section configuration, applied the benefits in an actual multi-housing case study complex. In examining the measurement test results of the runoff water infiltration amount and surface runoff amount of a low-profile type green area(Dish type) and a general type green area(Mound type), Dish type was seen to have 1.5-times higher runoff water infiltration amount than Mound type during heavy rainfalls and showed about a 50% reduction with respect to the surface runoff amount. In other words, artificial soil green area offers the benefit of reduction of surface runoff amount and suggests, in actuality even with a change to the cross-sectional configuration of artificial soil green area alone at the time of construction of multi-housings, the possibility of benefits and reduction of costs spent on existing rainwater management facilities.

Study on Improving Surface Structure with Changing RF Power Conditions in RIE (reactive ion etching) (반응성 이온 건식식각에서 RF Power 변화에 따른 표면 조직화 개선 연구)

  • Park, Seok-Gi;Lee, Jeong In;Kang, Min Gu;Kang, Gi-Hwan;Song, Hee-eun;Chang, Hyo Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.455-460
    • /
    • 2016
  • A textured front surface is required in high efficiency silicon solar cells to reduce reflectance and to improve light trapping. Wet etching with alkaline solution is usually applied for mono crystalline silicon solar cells. However, alkali texturing method is not appropriate for multi-crystalline silicon wafers due to grain boundary of random crystallographic orientation. Accordingly, acid texturing method is generally used for multi-crystalline silicon wafers to reduce the surface reflectance. To reduce reflectivity of multi-crystalline silicon wafers, double texturing method with combination of acid and reactive ion etching is an attractive technical solution. In this paper, we have studied to optimize RIE condition by different RF power condition (100, 150, 200, 250, 300 W).

Hybrid Anti-aliasing Method for 3D Object represented by Point Sampling (포인트 샘플링으로 표현된 3차원 객체를 위한 하이브리드 앤티앨리어싱 방법)

  • Kim, Hak-Ran;Park, Hwa-Jin
    • Journal of Digital Contents Society
    • /
    • v.8 no.1
    • /
    • pp.85-91
    • /
    • 2007
  • This paper proposes a new hybrid anti-aliasing method for reducing aliasing appearing on an implicit surface using the point sampling. The hybrid anti-aliasing method is a method that finds differences in the values of pixel shown in Z-buffers for an implicit surface and thereby uses each of three types of Z-buffer. After determining the level of differences, it expresses a 3 dimensional object by using a multi Z-buffer if the level is severe, a double Z-buffer for a middle level, and only the original Z-buffer for a negligible difference. In comparison with the existing method in which multi Z-buffers have been entirely used for enhancing the anti-aliasing effect, the hybrid anti-aliasing method is an efficient method demonstrating an effect similar to the one using a multi Z-buffer while reducing the number of Z-buffers to be used.

  • PDF

Properties of Hydorogenated Al-Doped ZnO Films by Multi-Step Texture (다단계 습식 식각을 통한 수소처리된 Al-doped ZnO 박막의 특성)

  • Tark, Sung-Ju;Kang, Min-Gu;Park, Sun-Geun;Kim, Yong-Hyun;Kim, Won-Mok;Kim, Dong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.19 no.5
    • /
    • pp.259-264
    • /
    • 2009
  • In this study we investigated the effect of the multi-step texturing process on the electrical and optical properties of hydrogenated Al-doped zinc oxide (HAZO) thin films deposited by rf magnetron sputtering. AZO films on glass were prepared by changing the $H_2/(Ar+H_2)$ ratio at a low temperature of $150^{\circ}C$. The prepared HAZO films showed lower resistivity and higher carrier concentration and mobility than those of non-hydrogenated AZO films. After deposition, the surface of the HAZO films was multi-step textured in diluted HCl (0.5%) for the investigation of the change in the optical properties and the surface morphology due to etching. As a result, the HAZO film fabricated under the type III condition showed excellent optical properties with a haze value of 52.3%.

Liquid Crystal Alignment on Multi-stacked Layer HfO2 Thin Films Using a Solution-process (용액 공정 기반의 다중 적층된 HfO2 박막 상에서의 액정 배향)

  • Kim, Dai-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.11
    • /
    • pp.821-825
    • /
    • 2013
  • Effect of multi-stacked layer (MSL), 0.1 mol (M) and 0.3 mol (M) hafnium oxide ($HfO_2$) alignment layers were fabricated via a solution-process for LCs orientation. The solutions were spin-coated and annealed in a furnace. MSL consists of three sub-layers using 0.1 M solution, mono-layer (ML) is composed of 0.3 M $HfO_2$ solution. Then ion-beam irradiation was treated with 1.8 keV for 2 min. $HfO_2$-based LC cells were investigated through photographs, pre-tilt angle using crystal rotation method, X-ray photoelectron spectroscopy (XPS) measurement, and surface roughness using atomic force microscopy(AFM) for their characteristic research. Good LC orientation characteristics were observed on MSL $HfO_2$ surface. The LC alignment mechanism on MSL $HfO_2$ and ML $HfO_2$ surfaces was attributed to van der Waals (VDW) interaction between the LC molecular and substrate surface.

R-22 and R-410A Condensation in Flat Aluminum Multi-Channel Tubes (알루미늄 다채널 평판관내 R-22 및 R-410A 응축에 관한 연구)

  • Jung, Ho-Jong;Kim, Nae-Hyun;Yoon, Baek;Kim, Man-Hoi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.575-583
    • /
    • 2002
  • In this study, condensation heat transfer tests were conducted in flat aluminum multi-channel tubes using R-410A, and the results are compared with those of R-22. Two internal geometries were tested; one with a smooth inner surface and the other with micro-fins. Data are presented for the following range of variables; vapor quality (0.1~0.9), mass flux (200~600 kg/$m^2$s) and heat flux (5~15 ㎾/$m^2$). Results show that the effect of surface tension drainage on the fin surface is more pronounced for R-22 than R-410A. The smaller Weber number for R-22 may be responsible. For the smooth tube, the heat transfer coefficient of R-410A is slightly larger than that of R-22. For the micro-fin tube, however, the reverse is true. Possible reasoning is provided considering the physical properties of the refrigerants. For the smooth tube, a correlation of Akers et at. type predicts the data reasonably well. For the micro-fin tube, the Yang and Webb model was modified to correlate the present data.

Numerical Optimization of A Multi-Blades Centrifugal Fan For High-Efficiency Design (원심다익송풍기의 고효율 설계를 위한 수치최적설계)

  • Seo, Seoung-Jin;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.385-390
    • /
    • 2003
  • Shape of a multi-blades centrifugal fan is optimized by response surface method based on three-dimensional Navier-Stokes analysis. For numerical analysis, Reynolds-averaged Wavier-Stokes equations with standard $k-{\varepsilon}$ turbulence model are transformed into non-orthogonal curvilinear coordinate system, and are discretized with finite volume approximations. Due to the large number of blades in this centrifugal fan, the flow inside of the fan is regarded as steady flow by introducing the impeller force models for economic calculations. Optimizations with and without constraints are carried out. Design variables, location of cur off, radius of cut off, expansion angle of scroll and width of impeller were selected to optimize the shapes of scroll and blades. Data points for response evaluations were selected by D-optimal design, and linear programming method was used for the optimization on the response surface. As a main result of the optimization, the efficiency was successfully improved. The correlation of efficiency with relative size of inactive zone at the exit of impeller is discussed as well as with average momentum fluxes in the scroll.

  • PDF

Effects of Multi-Complex Agent Addition on Characteristics of Electroless Ni-P Solution (복합 착화제 첨가가 무전해 Ni-P 도금액의 특성에 미치는 영향)

  • Lee, Hong-Kee;Lee, Ho-Nyun;Jeon, Jun-Mi;Hur, Jin-Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.2
    • /
    • pp.111-120
    • /
    • 2010
  • In this study, the effects of multi-complex agents addition on characteristics of electroless Ni plating solution are investigated. The species and the concentration of complexing agents are major factors to control the deposition rate, P concentration, and surface morphology of plating films. Adipic acid increases the deposition rate in regardless of single- or mutli-complex agent addition. However, lactic acid effectively increases the deposition rate in case of multi-addition as the complex agents with adipic or sodium succinate acid. In addition, sodium citric acid and malic acid show good stabilizing effects of plating solution and lowering the deposition rate, because they have high complexibility. Therefore, it is suggested that the development of Ni-P plating solution suitable for diverse usages can be carried out systematically using the database from this study.

Study of the Reduction of Torque Ripples for Multi-pole Interior Permanent Magnet Synchronous Motors using Rotor Saliency (회전자 돌극 설계를 이용한 다극 매입형 영구자석 동기전동기의 토크리플 저감 연구)

  • Kim, Ki-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6270-6275
    • /
    • 2014
  • The paper reports an improvement method on torque ripples of multi-pole interior permanent magnet synchronous motor (IPMSM) applied to a traction motor for hybrid electric vehicles. In the case of multi-pole IPMSM, the magnetic flux generated by a permanent magnet tends to leak through the bridge of the rotor without a link with stator windings. The slit design on the rotor surface was proposed to reduce torque rippling and increase the output power by reducing the leakage flux. Two design parameters for the slit are suggested for optimal design using the response surface method. As an analysis method, the 2D finite element method (FEM) was applied to consider magnetic saturation effect.