• Title/Summary/Keyword: Multi-Spray

Search Result 180, Processing Time 0.025 seconds

A Study on the Emission and Dispersion of Particulate Matter from a Cement Plant (한 시멘트공장의 분진발생과 대기확산에 관한 조사연구)

  • Chang, Man-Ik;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.67-77
    • /
    • 1983
  • To investigate the an air pollution by particulate matter and its dispersion, a cement plant produceing portland cement 600,000 ton/year and its vicinity were surveyed from Obtober, 1980 to April, 1983. The survey was mainly focused on main stack emmission rate of the cement plant and particle size distribution in the dust, dustfall and total suspended particulate concentration in the area by month and distance from the stack. The results of the study were as follows; 1. The main stack emission rate was surveyed before and after the spray tower was additionally installed to the original E.P bag filter. Before the spray tower installed, the main stack emission rate was higher ($0.64g/Nm^3$) than the emission standard of Korean Environmental Preservation Law's ($0.59g/Nm^3$, amended to $0.4g/Nm^3$ on April 1983), but after the spray tower was installed, its main stack emission rate was markedly decreased to the standard ($0.43g/Nm^3$). 2. $2{\sim}3{\mu}m$ of the particle size was the largest portion (20.8%) of the dust particulate from the main stack and 50% of the frequency distribution was $1.5{\mu}m$ of the size. Most particle size was below $10{\mu}m$. 3. The spray tower reduced the dustfall to $37.81{\sim}9.76\;ton/km^2/month$ while dustfall appeared at $45.29-15.45ton/km^2/month$, in the vicinity of plant before spray tower installed 4. Mean concentrations of total suspended particulate for 24 hours of the various stations were determined in $20.6-200.0{\mu}g/m^3$, 3 stations of tham were higher than the value of Harry and William's arthmetic average standard $130{\mu}g/m^3$. 5. Linear regression between dustfall [X] and total suspended particulate[Y] concentration was an equation, Y=4.024X+11.479.[r=0.91] 6. During the whole seasons in the opposite area 100m apart from the omission source the prevailing wind direction was with estimated more than $30ton/km^2/month$, and the concentration of total suspended particulate for 24 hours averaging time was more than $140{\mu}g/m^3$ in the same area and direction. 7. Assuming the wind direction were constant through the day dustfalls for a day were estimated at $13.40ton/km^2/day,\;10.79ton/km^2/day$ and $4.55ton/km^2/day$ at various distances of 100m, 500m and 1,500m from the emission source respectively. 8. In the simutalion of dustfall and suspended dust by area, Gaussian dispersion model modified by size distribution of particulate matter was not applicated since the emission of dust were from multi sources other them stack. From the above results, it could be applied that the dispersion of dust from the cement plant is estimated and regulated for the purpose of environmental protection.

  • PDF

수성 고분자 - 탄소나노튜브 복합 분산 용액을 이용한 전계 방출 소자의 제작

  • Jeong, Hyeok;Kim, Do-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.66.2-66.2
    • /
    • 2011
  • A polymer-based multi-walled carbon nanotube (MWCNT) field emission device was fabricated from a composite dispersion of MWCNTs and waterborne polymethyl methacrylate (PMMA). The waterborne PMMA synthesized through the emulsion polymerization method was added to minimize the reagglomeration of dispersed MWCNTs with surfactants in water, and increase the adhesion between the and the substrate. The field emission properties of the fabricated device were optimized by adjusting the density of the emitter and the adhesion between the MWCNTs and the substrate. These were done by controlling the polymer concentration added to the MWCNT dispersion, as well as the amount of spray coating on the substrate. The results confirm the successful fabrication of a polymer-based MWCNT field emission device with a low field of 1.07 $V/{\mu}m$ and a good electric field enhancement factor of 2445. The device was fabricated by adding 0.8 mg/mL of polymer solution to the MWCNT dispersion and applying 20 cycles of spray coating. Application of this same MWCNT/polymer composite solution to a flexible polymer substrate also resulted in the successful fabrication of an electric field emission device with uniform emission and long time stability.

  • PDF

Assemblage and Driving Characteristics of a Ultrasonic Fabric Washing Machine (초음파 직물수세기의 구성 및 구동 특성)

  • 이춘길;이광수
    • Textile Coloration and Finishing
    • /
    • v.12 no.3
    • /
    • pp.207-217
    • /
    • 2000
  • A new, high-efficiency ultrasonic fabric washing machine was developed to be an energy-efficient washing machine and to enhance fabric washing quality in washing processes of the dyeing and finishing process in the textile industry. This system is composed of ultrasonic wave generator, air blowing nozzle, torque motor for fabric tension control, and enclosed washing bath, multi-tube type exchanger, noiseless heater, air cylinder, expander roller, mangle upper and lower rollers, bend bar, dancer, shower spray nozzle, and solenoid valve, and so on. These elements are synergised for fabric washing. One of the very important principles is the low tension fabric running system. For an efficient washing effect, a counter flow system is also adopted. The new system also adopts the dancer and torque motor to control fabric tension and prevent fabric creasing. Shower spray nozzle, counter flow and overflow apparatus, and air-blowing apparatus are adopted to enhance the fabric washing effect. In this study, peach yoryu, exter, and moss crepe fabrics were washed by the general and ultrasonic washing systems under different conditions respectively. The washing efficiency was affected by the fabric running speed and characteristics of fabrics. Size content after washing increased with increasing the fabric running speed. The values in the general washing system were higher than those of the ultrasonic washing system. The changes of conductivity in the ultrasonic and the cooling bath were affected by the running time under the ultrasonic generating. The values of conductivity decreased as the experimental time passed.

  • PDF

Improvement of Spray Coating Uniformity using ESD Electrodes (ESD 전극을 이용한 분무코팅 균일도 개선에 관한 연구)

  • Dang, Hyun-Woo;Yang, Seong-Wook;Doh, Yang-Hoi;Choi, Kyung-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.2
    • /
    • pp.118-124
    • /
    • 2016
  • In this study, experiments are conducted to improve spray coating uniformity by using second and third electrodes based on the electrospray atomization mechanism. The uniformity of fabricated thin films can be improved by adjusting the design of the second electrode. The implementation of the second electrode with an elongated hole and a bending angle of $90^{\circ}$ results in highly uniform films. In addition, induced area to substrate is increased by lowering the applied voltage using the third electrode with a round rod shape. A linear correlation between applied voltage and induced area is confirmed. Thin film thickness and surface roughness are measured after the fabrication of thin films through the electrospray process. It is confirmed that a thin film is formed having an average thickness of 273.44 nm, a thickness uniformity of less than 10%, and a surface roughness of 3 nm.

Icing Characteristics of Liquid Phase LPG Injection According to Butane and Propane Mixing Rates (부탄과 프로판 혼합비율에 따른 액상 LPG 분사시 Icing 특성)

  • Kim, Yung-Jin;Cho, Won-Joon;Lee, Ki-Hyung
    • Journal of ILASS-Korea
    • /
    • v.16 no.3
    • /
    • pp.146-151
    • /
    • 2011
  • LPG(Liquified Petroleum Gas) fuel for vehicles has lots of advantages such as low emission level, cheaper fuel cost and enough infrastructure. Therefore it arouses interest as an alternative engine to reduce emission of diesel engines. Especially MPI(Multi Point Injection) type LPLi(Liquid Phase LPG injection) system could have overcome the disadvantages of mixer types such as low engine performance, decreased charging efficiency and cold starting difficulty. However ice formation on the nozzle tip and intake port due to the freezing of moisture around the components is often observed in LPLi systems. This icing phenomenon is the direct cause of unstable engine combustion, resulting in engine emissions. Therefore in this research, a spray visualization test for LPG injection was carried out to obtain the basic information of an LPLi injector, then the effects of butane and propane mixing rates on ice formation at the intake port and nozzle tip was investigated. As a result, the icing characteristics of them showed contrary results according to the mixing rates.

Antitumor Activities of Spray-dried Powders with Different Molecular Masses Fractionated from the Crude Protein-bound Polysaccharide Extract of Agaricus blazei Murill

  • Hong, Joo-Heon;Kim, Seok-Joong;Ravindra, Pogaku;Youn, Kwang-Sup
    • Food Science and Biotechnology
    • /
    • v.16 no.4
    • /
    • pp.600-604
    • /
    • 2007
  • In this study, we first prepared 3 kinds of powders with different molecular masses from the crude protein-bound polysaccharide extract of Agraricus blazei Murill through ultrafiltration, followed by spray-drying. Then, the antitumor activities of the powders were analyzed. Size exclusion chromatography coupled with a multi-angle laser-light-scattering system showed the 3 powders had the following molecular ranges: below 10 kDa (SD-1), 10 to 150 kDa (SD-2), and above 150 kDa (SD-3), representing peak molecular weights of $8.26{\times}10^3,\;9.65{\times}10^4$, and $5.94{\times}10^6\;g/mol$, respectively. All the powders stimulated macrophage RAW264.7 cells to produce nitric oxide, of which SD-2 and SD-3 were superior to the crude extract powder (CP-SD), while SD-1 showed the lowest activity. Similar results were found for their cytotoxicities against human cancer cell lines (A549, MCF-7, and AGS), where the highest activity was obtained with the SD-2 treatment for 72 hr at $1,000\;{\mu}g/mL$. The MCF-7 cell line was less sensitive to the powders than the other cells. From this research we found that ultrafiltration, in combination with spray-drying, is applicable for preparing protein-bound polysaccharide powders with higher antitumor activities.

Surface Characteristic of Graphene Coated Stainless Steel for PEMFC Bipolar Plate (그래핀이 코팅된 스테인리스강의 고분자전해질 연료전지 분리판 적용을 위한 표면 특성)

  • Lee, Su-Hyung;Kim, Jung-Soo;Kang, Nam-Hyun;Jo, Hyung-Ho;Nam, Dae-Guen
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.5
    • /
    • pp.226-231
    • /
    • 2011
  • Graphene was coated on STS 316L by electro spray coating method to improve its properties of corrosion resistance and contact resistance. Exfoliated graphite (graphene) was made of the graphite by chemical treatment. Graphene is distributed using dispersing agent, and STS 316L was coated with diffuse graphene solution by electro spray coating method. The structure of the exfoliated graphite was analyzed using XRD and the coating layer of surface was analyzed by using SEM. Analysis showed that multi-layered graphite structure was destroyed and it was transformed into fine layers graphene structure. And the result of SEM analysis on the surface and the cross section, graphene layer was uniformly formed with 3~5 ${\mu}m$ thickness on the surface of substrate. Corrosion resistance test was applied in the corrosive solution which is similar to the PEM fuel cell stack inside. And interfacial contact resistance test was measured to simulate the internal operating conditions of PEM fuel cell stack. The results of measurements show that stainless steel coated with graphene was improved in corrosion resistance and surface contact resistance than stainless steel without graphene coating layer.

Effects of GMA Welding Conditions on the Bead Shape of Hardfacing Overlay Welding (하드페이싱 오버레이용접 비드형상에 미치는 GMA 용접조건의 영향)

  • Han, Kyu-Ho;Kim, Jun-Ki;Kim, Cheol-Hee;Kim, Jeong-Han;Nam, See-Hwan;Jeon, Chi-Jung
    • Journal of Welding and Joining
    • /
    • v.25 no.5
    • /
    • pp.58-63
    • /
    • 2007
  • The relationship between GMA welding conditions and the bead shape of overlay weld was studied by using ${\Phi}1.6mm$ hypo-eutectic metal-cored wire designed for hardfacing against the severe metal-to-metal wear. As the welding voltage increased, the dilution also increased but the sudden drop of dilution was observed at $30{\sim}33V$. It was considered to be due to the decrease of penetration resulting from the change of transfer mode, from short circuit to spray. It was also found that the behavior of penetration with welding current was dependant on the transfer mode. The short circuit mode exerted the penetration to decrease while the spray mode did it to increase with increase of welding current. The former was considered to be responsible for the remarkable decrease in dilution at low welding voltage region. The change of transfer mode also had an effect on the behavior of bead width with welding current but it did not on the bead spreadability defined as W/H ratio. It was considered that the optimal welding conditions for multi-pass overlay welding could be obtained from the bead spreadability suitable for bead lapping and the dilution as low as possible in the spray transfer mode.

Numerical Analysis of Cryogenic Liquid Nitrogen Jets at Supercritical Pressures using Multi-Environment Probability Density Function approach (다점 확률분포 모델을 이용한 초임계 압력 액체질소 제트 해석)

  • Jung, Kiyoung;Kim, Namsu;Kim, Yongmo
    • Journal of ILASS-Korea
    • /
    • v.22 no.3
    • /
    • pp.137-145
    • /
    • 2017
  • This paper describes numerical modeling of transcritical and supercritical fluid flows within a liquid propellant rocket engine. In the present paper, turbulence is modeled by standard $k-{\varepsilon}$ model. A conserved scalar approach in conjunction with multi-environment probability density function model is used to account for the turbulent mixing of real-fluids in the transcritical and supercritical region. The two real-fluid equations of state and dense-fluid correction schemes for mixtures are used to construct thermodynamic data library based on the conserved scalar. In this study, calculations are made on two cryogenic nitrogen jets under different chamber pressures. Sensitivity analysis for two different real-fluid equations of sate is particularly emphasized. Based on numerical results, precise structures of cryogenic nitrogen jets are discussed in detail. Numerical results show that the current real-fluid model can predict the essential features of the cryogenic liquid nitrogen jets.

Numerical Study on the Effect of Nozzle Geometry on the Small CRDI Engine Performance (노즐 형상 변경이 소형 CRDI 엔진의 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Min, Se Hun;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.20 no.4
    • /
    • pp.254-260
    • /
    • 2015
  • The objective of this study is to investigate the effect of multi-hole nozzle on the performance of small CRDI engine. Combustion and exhaust emission characteristics of engine were studied by using CFD simulation with ECFM-3Z combustion model. The conditions of simulation were varied with nozzle geometry, injection timing and injection quantity. In addition, the results were compared in terms of combustion pressure, rate of heat release, $NO_x$ and soot emissions. It was found that combustion pressure was increased when injection timing was advanced. The rate of heat release of 6 hole nozzle was higher than that of 12 hole nozzle since the quantity of fuel impinged at the bottom of piston rim was different under different injection timing conditions. In the case of $NO_x$ emission, 6 hole nozzle generated more $NO_x$ emission than 12 hole nozzle. On the other hand, in the case of soot emission, 12 hole nozzle showed higher value than 6 hole nozzle because injected fuel droplets from multi-hole nozzle were coalesced.