• Title/Summary/Keyword: Multi-Signal

Search Result 2,291, Processing Time 0.025 seconds

The Design of Multi Channel Receiver for Radar Systems (레이더용 다중채널수신기 설계)

  • Lee, Ki-Hong;Kim, Wan-Sik;Kim, Gye-Kuk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.203-207
    • /
    • 2010
  • In this paper, The design and implementation of Multi Channel Receiver is described in this paper. This Receiver system operates at X-band with processing received signal, more than 80[dB] dynamic range and wide-band signals at the same time. To process direct received signals, this system has the built-in Digital De-modulators which offer the minimum loss on the receiving signal pass and has high stability by adding Built-In Test (BIT). The performance of Multi Receiver is the following. The gain, noise figure, difference of amplitude and phase on the signal pass is respectively $14{\pm}2[dB]$, 19[dB], ${\pm}2[dB]$, and $10^{\circ}$ below.

  • PDF

A Study on the Difference Method of Magnetic Resonance Signal Measurement when Using Multi-channel Coil and Parallel Imaging

  • Choi, Kwan-Woo;Lee, Ho-Beom;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.220-226
    • /
    • 2017
  • SNR (signal to ratio) is a criterion for providing objective information for evaluating the performance of a magnetic resonance imaging device, and is an important measurement standard for evaluating the quality of MR (Magnetic Resonance) image. The purpose of our study is to evaluate the correct SNR measurement for multi-channel coil and parallel imaging. As a result of research, we found that both T1 and T2 weighted images show the narrowest confidence interval of the method recommended by NEMA (The National Electrical manufacturers Association) 1 having a single measurement method, whereas the ACR (American College of Radiology) measurement method using a multi-channel coil and a parallel imaging technique shows the widest confidence interval. There is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a ACR measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Multi-bit Sigma-Delta Modulator for Low Distortion and High-Speed Operation

  • Kim, Yi-Gyeong;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.29 no.6
    • /
    • pp.835-837
    • /
    • 2007
  • A multi-bit sigma-delta modulator architecture is described for low-distortion performance and a high-speed operation. The proposed architecture uses both a delayed code and a delayed differential code of analog-to-digital converter in the feedback path, thereby suppressing signal components in the integrators and relaxing the timing requirement of the analog-to-digital converter and the scrambler logic. Implemented by a 0.13 ${\mu}m$ CMOS process, the sigma-delta modulator achieves high linearity. The measured spurious-free dynamic range is 89.1 dB for -6 dBFS input signal.

  • PDF

Construction of HTS Multi-channel SQUID System

  • Lee, S.M.;Park, W.K.;Lee, H.J.;Moon, S.H.;Lim, S.H.;Kim, D.Y.;Oh, B.
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.47-50
    • /
    • 2000
  • We have constructed a multi-channel SQUID magnetometer system. The system is designed to operate normally with 10 high temperature direct coupled SQUIDs. The main features of the system include a remote control by serial communication, low noise with wide bandwidth and high slew rate by several MHz modulation, signal conditioning and calibration by digital signal processing.

  • PDF

Radar Return Signal Simulation Equipment Using MC-DDS (Multi-Channel Direct Digital Synthesis) (다채널 직접 디지털 합성을 이용한 레이더 반사 신호 모의 장치)

  • Roh, Ji-Eun;Yang, Jin-Mo;Yoo, Gyung-Joo;Gu, Young-Suk;Lee, Sang-Hwa;Song, Sung-Chan;Lee, Hee-Young;Choi, Byung-Gwan;Lee, Min-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.10
    • /
    • pp.966-980
    • /
    • 2011
  • Radar receiving echo signal provides target information - range, velocity and position by signal magnitude and Doppler shift, which are determined by target reflection characteristics and target maneuver. Target angle error is extracted from the magnitude ratio of difference channel to sum channel. In this paper, we introduce a radar Return Signal Simulation Equipment(RSSE) which is implemented for the purpose of performance analysis and evaluation of phased array multi-function radar(MFR). It generates multi-target environment with jamming signals using MC-DDS (Multi-Channel Direct Digital Synthesis), and has scalability by using the efficient hardware configuration. The performance of the developed RSSE has been evaluated under various test environments. Especially, we proved that required target detection performance is achieved by RSP(Radar Signal Processor) interfaced RSSE configuration.

Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components (용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구)

  • Nam, Mun-Ho;Yang, Jin-Wook;Cho, Kap-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.731-739
    • /
    • 2021
  • This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.

A New TWA-Based Efficient Signal Integrity Verification Technique for Complicated Multi-Layer RLC Interconnect Lines (복잡한 다층 RLC 배선구조에서의 TWA를 기반으로 한 효율적인 시그널 인테그러티 검증)

  • Jo Chan-Min;Eo Yung-Seon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.7 s.349
    • /
    • pp.20-28
    • /
    • 2006
  • A new TWA(Traveling-wave-based Waveform Approximation)-based signal integrity verification method for practical interconnect layout structures which are composed of non-uniform RLC lines with various discontinuities is presented. Transforming the non-uniform lines into virtual uniform lines, signal integrity of the practical layout structures can be very efficiently estimated by using the TWA-technique. It is shown that the proposed technique can estimate the signal integrity much more efficiently than generic SPICE circuit model with 5% timing error and 10% crosstalk error.

Noise Source Identification Scheme for Multi-Source Signal using the Cepstrum Technique (캡스트럼을 이용한 다중 응답신호의 소음원 해석기법)

  • Kim, Kyung-Yong;Lee, Jang-Myung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.6
    • /
    • pp.76-82
    • /
    • 2000
  • To reduce the radiated noise of ships, the noises which are generated from onboard machinery, propulsion system and transfer characteristics of structure must be identified. While the ship is operating, however, we can not directly measure each signal of inputs and characteristics of transfer passage, because measured signals are superimposed by multi source and multi transfer passage. In this paper, the signal processing method for separating noise sources and transfer functions from the measured response signal by the cepstrum technique is proposed. The proposed method is verified by application of simulated signal and impact test and shows usefulness by application of real ship test.

  • PDF

Performance Analysis of digital phase shifter using Hilbert transform (힐버트 변환을 이용한 디지털 위상천이기의 성능 분석)

  • Seo, Sang Gyu;Jeong, Bong-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.39-44
    • /
    • 2013
  • In this paper digital phase-shifter for multi-arm spiral antennas was designed by using Hilbert transform. All frequency components in input signal are phase-shifted for 90 degree by Hilbert transform, and the transform is implemented by FIT and IFIT. Digital phase-shifter generates two signals with phase difference of 90 degree by using Hilbert transform from input signals sampled by analog-digital converter(ADC), and then the input signal is phase-shifted for a given phase by using two signals. Hilbert transform based on digital phase-shifter is designed by Xilinx System generator, and the effects of input noise, FIT point, sampling period, initial phase of input signal, and shifted phase are simulated and its results are compared with Matlab results.

Design of Component-Based GNSS Multi-Band IF Signal Generator

  • Cho, Sung Lyong;Lim, Deok Won;Yeo, Sang-Rae;Park, Chansik;Hwang, Dong-Hwan;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.1 no.1
    • /
    • pp.29-34
    • /
    • 2012
  • A software GNSS signal generator for the GPS L1/L2/L5 and Galileo E1/E5 signals is proposed in this paper. And this signal generator is designed and implemented with several components by considering the reuse and expansion of components for similar GNSS signals. The characteristics of the reusability of the components are confirmed with the carrier generation and the band-pass filter components. And the functionality of the GNSS multi-band IF signal generator is validated by using the commercial software GPS L1 receiver, and the performance of signal acquisition, tracking and accuracy of horizontal position error are analyzed for this validation. As a result, the GPS L1 signal generator operates successfully and it could be expected that other signal generators also operate well because most of components are the same as those of the GPS L1 signal generator.