• 제목/요약/키워드: Multi-Level Inverter

검색결과 188건 처리시간 0.031초

Five-level Inverter for Excitation Control of SRM Drive

  • Oh, Seok-Gyu;Park, Sung-Jun;Ahn, Jin-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.64-69
    • /
    • 2001
  • Energy recovery in the regenerative region is very important when SRM is used in traction drive, This is to reduce en-ergy loss during mechanical braking and/or to have a high efficiency drive during braking To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM multi-level voltage control is effective The paper sug-gests multi-level inverter which is useful for motoring and regenerative operation in SRM

플라잉 커패시터 멀티-레벨 인버터의 커패시티 잔압 균형을 위한 캐리어 비교방식의 펄스 폭 변조 기법 (The Carrier-based SVPWM method for voltage balance of flying capacitor multilevel inverter)

  • 강대욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2000
  • This paper proposes a new solution by carrier-based SVPWM method to solve the most serious problem of Flying Capacitor Multi-level Inverter that is unbalance of capacitor voltages The voltage unbalance is occurred by the difference of each capacitor's charging and discharging time applied to Flying Capacitor Multi-level Inverter. It controls the variation of capacitor voltages into the mean'0' during some period by means of new carriers using the leg voltage redundancy in the Inverter. The solution can be easily expanded to the multi-level. Also this method can make the switching loss and conduction loss of device equal by the use of leg voltage redundancy. First the unbalance of capacitor voltage is analyzed and the conventional theory of self-balance using phase-shifted carrier is reviewed. And then the new method that is suitable to the Flying Capacitor Inverter is explained. The simulation results would be shown to verify the proposed method

  • PDF

3상 절연형 변압기를 이용한 다중레벨 (Multi-level Inverter Using 3-Phase isolated Transformers)

  • 이화춘;송성근;박성준;김광헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1134-1135
    • /
    • 2007
  • In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

  • PDF

멀티레벨 인버터와 다상 유도기를 이용한 견인기용 대전력 VSI의 구조와 특성 (Configurations of High Power VSI Drives for Traction Applications Using Multi Level Inverters and Multi Phase Induction Motors)

  • ;류홍제;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.500-504
    • /
    • 1997
  • Current source inverter drives of auto sequentially commutated type are very popular in high power applications, because of simple power circuit configuration with four quadrant operation. But the six-step current output create harmonic problems and the input power factor of such a drive is not always good. In this respect pulse width modulated drives using gate turn off thyristors ( GTO ) are finding application, especially in traction drives. However the switching and snubber loses of a GTO do not permit the inverter switching frequency go beyond a few hundred hertz.This will again introduce low frequency harmonic problems. Multi level inverters of the 3-level and 5-level can be considered as an alternative to overcome the low switching frequency harmonic problem of the 2-level GTO inverters. But with multi level inverters the complexity of the power circuit increases. In this paper a combination of multi level ( 2-level and 3-level ) inverters and multi phase induction motor ( 3-phase and 6-phase) configurations are presented for high power VSI drives for traction applications with reduced inverter switching frequency requirements coupled with reduced voltage rating for the power switch.

  • PDF

Soft Switching Multi Level Inverter를 이용한 HID용 Ballast (HID Ballast using Soft Switching Multi Level Inverter)

  • 이장선;김윤호;김수홍
    • 전력전자학회논문지
    • /
    • 제9권6호
    • /
    • pp.628-634
    • /
    • 2004
  • 차량용 전조등에 사용되어지는 HID(High Intensity Discharge) 발라스트(Ballast)의 특성 개선을 위하여 소프트 스위칭 방식의 멀티 레벨 인버터를 적용하였다. 멀티레벨 인버터의 모드(Mode)별 특성을 해석하고, 그 결과를 통해 발라스트의 출력 특성을 해석하고 시스템을 설계하였다. 그리고 실험을 통하여 해석결과를 확인하였다.

NTV 식별과정 없는 멀티레벨 인버터의 신속한 공간벡터 PWM 변조 기법 (Fast Space Vector PWM Modulation of Multi-Level Inverter Without NTV Identification)

  • 진선호;오진석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권6호
    • /
    • pp.299-305
    • /
    • 2006
  • In this paper, we suggest a new space vector PWM modulation method with very short processing time which does not need identification of nearest three vectors(NTV) and duty ratio for each vector. The suggested PWM method makes mean value of phase voltage to be same as reference during every modulation period by use of a triangle in small hexagon on multi-level vector space. This paper described the suggested modulation method can be successfully applied to the space vector modulation use of multi-level inverter by computer simulations and experiments.

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters)

  • 김윤호;김수홍;이강희
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석 (The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter)

  • 김수홍;김윤호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

Implementation of a High Efficiency Grid-Tied Multi-Level Photovoltaic Power Conditioning System Using Phase Shifted H-Bridge Modules

  • Lee, Jong-Pil;Min, Byung-Duk;Yoo, Dong-Wook
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.296-303
    • /
    • 2013
  • This paper proposes a high efficiency three-phase cascaded phase shifted H-bridge multi-level inverter without DC/DC converters for grid-tied multi string photovoltaic (PV) applications. The cascaded H-bridge topology is suitable for PV applications since each PV module can act as a separate DC source for each cascaded H-bridge module. The proposed phase shifted H-bridge multi-level topology offers advantages such as operation at a lower switching frequency and a lower current ripple when compared to conventional two level topologies. It is also shown that low ripple sinusoidal current waveforms are generated with a unity power factor. The control algorithm permits the independent control of each DC link voltage with a maximum power point for each string of PV modules. The use of the controller area network (CAN) communication protocol for H-bridge multi-level inverters, along with localized PWM generation and PV voltage regulation are implemented. It is also shown that the expansion and modularization capabilities of the H-bridge modules are improved since the individual inverter modules operate more independently. The proposed topology is implemented for a three phase 240kW multi-level PV power conditioning system (PCS) which has 40kW H-bridge modules. The experimental results show that the proposed topology has good performance.

SRM의 고속운전을 위한 새로운 멀티레벨 인버터의 구동특성 (Performance of Multi-level Inverter for High-Speed SR Drive)

  • 이동희;안진우
    • 전력전자학회논문지
    • /
    • 제12권3호
    • /
    • pp.234-240
    • /
    • 2007
  • 본 논문에서는 비대칭 컨버터에 비하여 전력소자의 수를 감소하면서도, 고속 운전에 적합한 새로운 멀티레벨 인버터를 제안한다. 제안된 인버터는 기존의 비대칭 컨버터에 비하여 전력소자의 수를 감소시킬 수 있는 특징이 있으며, SRM의 감자구간에서 휠링되는 에너지와 전원에서 공급되는 에너지를 교차적으로 활용하는 방식을 적용함으로써, C-dump 인버터에 비해 커패시터의 정격전압을 낮출 수 있는 장점이 있다. 또한, 제안된 멀티레벨 인버터의 동작 모드는 비대칭 컨버터에 비하여, 충전 레벨의 전원을 정역으로 활용하여 빠른 여자(Excitation)와 감자(Demagnetization) 모드를 가지게 되므로, 제어의 활용성이 매우 높다. 따라서, SRM의 고속 운전에 필요한 여자전류의 빠른 확립을 통하여 응답시간을 개선시키며, 토크 발생구간을 확장시킬 수 있다. 제안된 멀티레벨 인버터 구동형 SRM의 운전특성은 시뮬레이션과 실험을 통해 검증하였다.