• Title/Summary/Keyword: Multi-Fluidized-Bed

Search Result 17, Processing Time 0.021 seconds

Microstructure and Nano-hardness of SiC/C Multi-coated Layers on a Particulate Nuclear Fuel (입자 핵연료의 SiC/C 다층 도포층의 미세조직 및 극미세 경도 평가)

  • Choi, Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.6
    • /
    • pp.321-325
    • /
    • 2019
  • Triso-type coating layers of silicon carbide and graphite on UO2 paticulate nuclear fuel were prepared by using fluidized bed type chemical vapor deposition and self-propagating high temperature synthesis methods to make a coated nuclear fuel of a power plant for hydrogen mass-production. The source and carrier gases were the mixture of methyltrichlorosilane and propane, and inert argon. Chemical analysis and microstructure observation showed that the coated layers were inner graphite, middle silicon carbide and outer graphite. The elastic modulus and nano-hardness of the silicon carbide layer were 503 [GPa] and 36 [GPa], respectively.

Controlled Release of Doxazosin in Multi-layered Pellet Using Polymer Blending (고분자 블렌딩을 이용하여 제조된 독사조신 다중층 펠렛의 약물방출제어)

  • Youn, Ju-Yong;Park, Sang-Wook;Lee, Soo-Young;Kim, Moon-Suk;Lee, Bong;Khang, Gil-Son;Lee, Hai-Bang
    • Polymer(Korea)
    • /
    • v.32 no.4
    • /
    • pp.322-327
    • /
    • 2008
  • In this study, a multi-layered pellet was composed of a seed layer including a water-swellable agent and a drug layer containing doxazosin as a model drug, a porous membrane and a castor oil layer to control drug release. The pellet is prepared by a fluidized bed coating method. To confirm drug release from polymer blending in multi-layered pellet system, it is prepared by containing different ratio such as hydroxypropylmethylcellulose (HPMC) : ethyl cellulose (EC) in drug layer and cellulose acetate(CA) : Eudragit RS in membrane. Also, to confirm the effect of oil in drug release, castor oil is coated. As a result, we observed regularly spherical pellet with diameter of $1500{\mu}m$. Release pattern of drug is confirmed by dissolution tester in aqueous media. The more the ratio of EC in drug layer, CA in membrane, and castor oil layer in pellet, the less the drug release is observed. Formation and the amount of pores in membrane is observed by SEM.

The First Part of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (동해화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용(1))

  • Ryu, Ho-Seon;Kim, Bong-Suck
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.259-261
    • /
    • 2007
  • 논문은 동해화력발전처의 이차공기송풍기를 가변 회전수 제어하여 소내 소비 전력을 절감하고 전동기의 직입기동에 의한 스트레스를 줄이기 위하여 실증 적용된 동해화력발전처 이차 공기 송풍기 구동용 H-브릿지 멀티레벨 인버터에 관한 것이다. H-브릿지 멀티레벨 인버터는 독립적으로 절연된 직류 부를 갖는 저압의 단상 인버터(셀 인버터)를 다수 직렬 접속하여 고압 3상 전압을 출력하는 Cascaded H-브릿지 전압형 인버터이다. 본 논문에서는 동해화력발전처에 실증 적용된 6.6kV, 1MVA급 인버터의 계통 병입 후 부하 변동 시험을 통하여 신뢰성을 입증하였다.

  • PDF

The Second Part of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (동해화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용(2))

  • Ryu, Ho-Seon;Kim, Bong-Suck
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.262-264
    • /
    • 2007
  • 최근 전압 및 주파수 가변을 이용하여 전동기의 속도를 제어하여 전동기 경부하시 베인에서 소모되는 에너지 절감효과를 얻을 수 있는 인버터 시스템이 널리 사용되고 있다. 이에 전력연구원은 6.6kV, 1MVA급 인버터 개발 및 동해화력 발전처에 설치, 보일러 점화 전/후 시험, 계통 병입 후 부하 시험 등을 국내 최초로 성공적으로 완료하여 현재 이차 공기 송풍기 구동용 인버터는 상업 운전 중이다. 본 논문에서는 기존 동해화력 발전 설비와 신규 인버터 시스템의 인터페이스 부분에 해당하는 보일러 DCS 로직과 계통 병입 후 시운전 결과에 대하여 상세히 기술하였다.

  • PDF

A Study on the Improvement of Potassium Based Sorbent for Flue Gas Carbon Dioxide(CO2) (배가스 이산화탄소(CO2)용 Potassium계 흡수제의 성능 향상 연구)

  • Wi, Young Ho;Ryu, Chong Kul;Choi, Dong Hyeok
    • Journal of Climate Change Research
    • /
    • v.2 no.2
    • /
    • pp.107-113
    • /
    • 2011
  • In this research, we described the experimental results for the improvement of Potassium based sorbents. These sorbents have been actually used in the 0.5 MW $CO_2$ capture plant located in Hadong #3 Power Plant. Firstly, we had shaped two kinds of sorbents using a spray dryer. These sorbents applied magnetite & copper oxide as an additive. And the magnetite sorbent was evaluated more excellent relatively in the attrition index. Secondly, We had obtained TGA multicycle experimental results of the improved Potassium based sorbent which applied magnetite as an additive. Consequently, $CO_2$ sorption capacity had been sustained 5.5 wt% after 2nd cycle and attrition index was very excellent as 0.5%. Finally, we had investigated the characteristics of the sorbent following in properties of supporters. As a result, the sorption capacity of the KMO sorbent used base material as a supporter was appeared as 7.2 wt%.

A Study on the Growth Characteristics of Commercially Developed Nitrifying Bacteria and its Application to Activated Sludge Process (상업용 질산화 박테리아의 성장특성과 활성슬러지 공정에서의 적용 방법에 따른 연구)

  • Whang, Gyu-Dae;Lee, Bong-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.595-604
    • /
    • 2006
  • The growth characteristics of Commercially Developed Nitrifying Bacteria (CDNB) were studied in laboratoryscale. CDNB, a pure, artificially isolated bacterium, was cultivated to produce Cultivated Nitrifying Bacterium Group (CNBG). The average ammonia removal rate of CDNB was 0.0234g $NH_4^+-N/g$ MLSS/hr. CNBG was produced in the batch reactor and Specific Nitrification Rate (SNR) was determined at 0.0107g $NH_4^+-N/g$ MLSS/hr. The SNR of CNBG was lower than the SNR of CDNB because the diverse and multi-cultured microbial growth took place during cultivation. The effect of the temperatures and the mixing ratios of sewage and culture solution on the SNR of CNBG was studied. The SNR of CNBG, 0.0107g $NH_4^+-N/g$ MLSS/hr at $27^{\circ}C$, decreased to 0.0048g $NH_4^+-N/g$ MLSS/hr at $15^{\circ}C$, and temperature coefficient (${\Theta}$) was calculated to be 1.07. With the varied sewage mixing ratios, the SNR of CNBG remained unchanged. Activated sludge reactors maintaining an MLSS of 2,000mg/L at HRT of 4 h were operated under conditions in which dosage of Concentrated CNBG Solution (CCNBGS, 10,000mg MLSS/L) and application method of CNBG were varied. The reactor with 20mL of CCNBGS took shorter time to oxidize $NH_4^+-N$ reaching 1mg/L than the reactor with 5mL of CCNBGS showing that higher dosages were associated with greater mass removal of $NH_4^+-N$. However, the total removal was not great. In terms of different methods of CNBG application, reactor seeded with 20mL of CCNBGS took 3days to reach 1mg/L of effluent ammonia concentration while reactor dosed with 20% (v/v) CNBG implanted media took 2days. Both the control reactor and the reactor dosed with 20% (v/v) media only did not reach 1mg $NH_4^+-N/L$ after operating 18days. The reactor with CNBG implanted media had the highest $NH_4^+-N$ removal rate because of maintaining high concentration of Nitrifying Oxidizing Bacteria (NOM), and is regarded as an appropriate method for the activated sludge process.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.