• Title/Summary/Keyword: Multi evaporator

Search Result 82, Processing Time 0.026 seconds

H2S Micro Gas Sensor Based on a SnO2-CuO Multi-layer Thin Film

  • Kim, Sung-Eun;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.1
    • /
    • pp.27-30
    • /
    • 2012
  • This paper proposes a micro gas sensor for measuring $H_2S$ gas. This is based on a $SnO_2$-CuO multi-layer thin film. The sensor has a silicon diaphragm, micro heater, and sensing layers. The micro heater is embedded in the sensing layer in order to increase the temperature to an operating temperature. The $SnO_2$-CuO multi layer film is prepared by the alternating deposition method and thermal oxidation which uses an electron beam evaporator and a thermal furnace. To determine the effect of the number of layers, five sets of films are prepared, each with different number of layers. The sensitivities are measured by applying $H_2S$ gas. It has a concentration of 1 ppm at an operating temperature of $270^{\circ}C$. At the same total thickness, the sensitivity of the sensor with multi sensing layers was improved, compared to the sensor with one sensing layer. The sensitivity of the sensor with five layers to 1 ppm of $H_2S$ gas is approximately 68%. This is approximately 12% more than that of a sensor with one-layer.

The Fault Detection of an Air-Conditioning System by Using a Residual Input RBF Neural Network (잔차입력 RBF 신경망을 사용한 냉방기 고장검출 알고리즘)

  • Han, Do-Young;Ryoo, Byoung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.780-788
    • /
    • 2005
  • Two different types of algorithms were developed and applied to detect the partial faults of a multi-type air conditioning system. Partial faults include the compressor valve leakage, the refrigerant pipe partial blockage, the condenser fouling, and the evaporator fouling. The first algorithm was developed by using mathematical models and parity relations, and the second algorithm was developed by using mathematical models and a RBF neural network. Test results showed that the second algorithm was better than the first algorithm in detecting various partial faults of the system. Therefore, the algorithm developed by using mathematical models and a RBF neural network may be used for the detection of partial faults of an air-conditioning system.

A Dynamic Simulation Model of Electronic-Expansion-Valve-Controlled Evaporators (전자팽창밸브 제어성능 모사용 증발기 동특성 모델링)

  • Shin, Young-Gy;Cho, Soo;Tae, Choon-Seob;Jang, Cheol-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.183-190
    • /
    • 2007
  • Controlling superheat of indoor units associated with a multi-type heat pump is one of difficult tasks to be addressed. This study suggests a dynamic model of an evaporator based on heat and mass balance. Thermodynamic properties are calculated by a commercial software, Refprop. The model is programmed in MFC Visual C++ for controller interface in real-time mode. The simulation results shows that PI control works for a narrow range of superheat. Beyond the range, the temperature behavior of the refrigerant is quite nonlinear mainly due to phase change. Thus, it is concluded that PI control of superheat has to be supplemented by nonlinear control ideas to avoid saturation and excessive superheat.

Temperature Characteristics of Cascade Refrigeration System by Pressure Adjustment

  • Chung Han-Shik;Jeong Hyo-Min;Kim Yeong-Geun;Rahadiyan Lubi
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2303-2311
    • /
    • 2005
  • Super low temperature has many applications nowadays, from the chemical processing, automotives manufacturing, plastic recycling, etc. Considering of its wide application in the present and the future, study of the super-low temperature refrigeration system should be actively carried out. Super low state temperature can be achieved by using multi-stage refrigeration system. This paper present the development and testing of cascade refrigerator system for achieving super-low temperature. On this experiment, two different types of HCFCs refrigerants are utilized, R-22 and R-23 were applied for the high stage and the low-pressure stage respectively. The lowest temperature in the low-pressure evaporator that can be achieved by this cascade refrigeration system is down to $-85^{\circ}C$. This experiment is aimed to study the effect of inlet pressure of the low-pressure stage evaporator and low-pressure stage compressors inlet pressure characteristics to the overall temperature characteristics of cascade refrigeration system.

Thermo-Hydrodynamic Behaviors of Open Channel Flow Inside A Multi-Stage Flash Evaporator (다단 후래시 증발장치내 개수로 유동의 열.수력학적 거동)

  • 설광원;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.702-715
    • /
    • 1990
  • This paper describes behaviors of two-phase open channel flow inside the flash chamber of a horizontal Multi-Stage-Flash evaporator numerically along with the experimental observations. Bubble trajectories and the velocity and temperature distributions of the liquid phase were predicted by using the particle-source-in-cell(PSI-Cell) method with the appropriate bubble motion/growth equations. Size and number of bubble nuclei embedded in the incoming liquid(brine) were taken into account as important parameters in addition to the conventional ones such as the velocity, degree of inlet superheat, inlet opening height, and the liquid level. Bubble motions, which are unsteady, appeared to be mostly determined by the buoyancy and the drag forces. The calculations, though a number of simplifying assumptions were made, reasonably simulated the hydrodynamic behaviors of the two-phase horizontal stream observed in the experiments. The simulated temperature distributions also agreed fairly well with the other's measurements. Non-equilibrium allownaces, evaluated from the simulated temperature distributions, were within the range of those obtained from the existing correlations, and reduced with the increases of the number and size of incoming bubble nuclei due to vigorous flashing.

Heating Performance of a Ground Source Multi-Heat Pump for a Greenhouse (지열원 멀티 열펌프 시스템의 시설원예 적용 난방성능 특성 실증 연구)

  • Kang, Shin-Hyung;Choi, Jong-Min;Moon, Je-Myung;Kwon, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.337-344
    • /
    • 2010
  • Good plant-growth conditions can be achieved by means of using greenhouses. One of the main issues in greenhouse cultivation is energy savings through the development of high efficient heating and cooling system. GSHPs are one of the recommended systems to cope with this pending need. The aim of this study is to investigate the heating performance of ground source multi-heat pump system installed in a greenhouse under part load conditions. Daily average heating COP of the heat pump unit was very high by at least 7.4, because of relatively large condenser, evaporator, and mass flow rate through ground loop heat exchanger. However, the system COP, overall heating coefficient of the performance of the system with heat pump unit and GLHX, decreased drastically due to relatively large power consumption of circulating pump under part load condition. It is suggested that the technology to enhance the performance of the ground source multi-heat pump system for a greenhouse under part load conditions should be developed.

The optical properties of ZnS/$Na_3AlF_6$/ZnS multi-layered thin film with Co reflection layer (ZnS/$Na_3AlF_6$/ZnS 박막의 Cu 반사층을 이용한 광 특성)

  • Kim, Jun-Sik;Jang, Gun-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.322-323
    • /
    • 2008
  • Multi layered thin films with ZnS/$Na_3AlF_6$/ZnS were deposited on glass substrate by thermal evaporator precess and simulated by using EMP(Essential Macleod Program). EMP is a comprehensive software package to design and analyse the optical characteristics of multi-layered thin film. ZnS and $Na_3AlF_6$ were selected as a high refractive index and low refractive index material respectively. Additionally Cu was chosen as mid reflective material. Optical properties including color effect were systematically studied. in terms of different optical thickness of low refractive index material. The optical thickness of $Na_3AlF_6$ was changed as 0.25, 0.5, 0.75 and $1.0\lambda$. The film with 0.25, 0.5, 0.75 and $1.0\lambda$. of optical thickness showed mixed color range between bluish green and red purple, yellowish green and bluish green, purple and mixed color range of green and purple respectively.

  • PDF

Design of Optimized Multi-Fuzzy Controller for Air Conditioning System (에어컨 시스템에 대한 최적화된 Multi-Fuzzy 제어기 설계)

  • Jeong, Seung-Hyeon;Choe, Jeong-Nae;O, Seong-Gwon;Kim, Hyeon-Gi
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.11a
    • /
    • pp.374-377
    • /
    • 2006
  • 본 논문은 에어컨 시스템의 효율성과 안정성에 기초하여, 과열도와 저압을 제어하는 Fuzzy 제어기 설계를 제안한다. 에어컨 시스템은 Compressor(압축기), Condenser(응축기), Evaporator(증발기), Expansion Valve(확장 밸브) 로 구성되며, 각각의 기기에 대한 제어가 독립적으로 이루어져 있다. 기존의 제어가 한 제어기를 사용한 단일방식으로 이루어지다보니 에어컨 시스템의 특성인 냉매의 상태가 달라지면 시스템 전반적으로 그 영향이 파급되는 부분까지 고려를 해 주지 못하고, 제어기의 성능이 효율적이고 안정적이지 못했다. 본 논문에서는 에어컨 시스템의 효율과 안정도에 결정적인 영향을 미치는 과열도와 저압(증발기의 압력)을 제어하기 위해, 비선형성이 강하고 불확실하며 복잡한 시스템을 쉽게 제어할 수 있는 Fuzzy 제어기를 구성하여, Expansion Valve 와 Compressor 에서 동시에 제어하는 Multi 제어기를 설계한다. 제안된 Fuzzy 제어기는 이산형 lookup_table 방식과 연속형 간략추론 방식을 사용하여 제어기를 설계하고, 유전자 알고리즘(GAs)을 이용하여 최적의 Fuzzy 제어기의 환산계수를 구한다. 그리고 시뮬레이션 결과를 통해 이산형 lookup_table 방식과 연속형 간략추론 방식의 각각의 제어기를 사용한 결과를 비교한다.

  • PDF

Evaluation and design of Multi-layered thin films with EMP simulation (EMP simulation을 활용한 다층 박막의 평가 및 설계)

  • Kim, Jun-Sik;Jang, Gun-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.312-312
    • /
    • 2009
  • 본 연구에서는 Thermal evaporator(저항 가열 식 진공 증착법) 장비를 활용하여 ZnS/$Na_3AlF_6$/ZnS/Cu-$0.25\lambda$, ZnS/$CaF_2$/ZnS/Cu-$0.25\lambda$의 다층 박막을 glass 기판위에 증착하였다. 증착 전에 EMP(Essential Macleod Program)을 활용하여 광학적 특성을 simulation하였으며 다층 박막 제작 후 Spectrophotometer를 사용하여 반사율 및 색상을 CIE $L^*a^*b^*$ 좌표에 표시하여 고 굴절 물질에 따른 광학적 특성을 EMP simulation과 비교하였다. AES depth profile을 분석하여 막의 두께 및 층간 확산여부에 관하여 관측 하였다. 저굴절 물질을 Na3AlF6로 사용하였을 경우 simulation과 결과 값 모en purple 계통의 색상을 나타냈으며 CaF2를 사용하였을 경우 simulation은 purple 계통의 색상, 결과값은 red-yellow 계통의 색상으로 나타났다.

  • PDF