• Title/Summary/Keyword: Multi Ground

Search Result 1,138, Processing Time 0.031 seconds

The Acid Rock Drainage and Hydraulic Characteristics of the Waste Rock Dump (폐석적치장의 산성배수발생 및 수리특성 분석)

  • Cheong, Young Wook;Ji, Sang Woo;Yim, Gil Jae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.4
    • /
    • pp.13-24
    • /
    • 2004
  • This study was carried out to plan the prevention of the generation and discharge of Acid Rock Drainage (ARD). The Acid Base Accounting(ABA) test was performed for geological materials such as pit wall, waste rock and stream sediments near the Imgi abandoned pyrophyllite mine in Busan, Korea. In addition, hydraulic characteristics were tested with the disk tension infiltrometer around the waste rock dump. Maximum Potential Acidity(MPA) of geological materials near the Imgi mine was 246.942kg $H_2SO_4/t$, and maximum Acid Neutralising Capacity(ANC) was 8.7kg $H_2SO_4/t$. These results indicate the pit wall and waste rock, except most of stream sediments are acid generating geological materials. These have salt and free hydrogen ion which resulted from oxidation of sulfides. Hence they could be convert rain water to acid rock drainage. Although the waste rock dump of the Imgi mine have very low infiltration rate, slopes of the waste rock dump have many "V" type erosion gullies and multi-layers. These gullies and multi-layers have coarse clastic particle layers which have very large hydraulic conductivity. Through this coarse clastic particle layer a large part of rain flow into ground. And also this layer could function as aeration path which induced oxidation of sulfide minerals and generation of ARD continuously.

  • PDF

Comparison of Nitrogen Dioxide Retrieved by MAX-DOAS and OMI measurements in Seoul (지상원격측정 MAX-DOAS 시스템과 위성 OMI센서로 서울에서 산출된 이산화질소 층적분농도의 비교연구)

  • Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.2
    • /
    • pp.235-241
    • /
    • 2013
  • $NO_2$ vertical column densities were retrieved via ground based Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) measurements for the first time for 6 months over the spring season in 2007 and 2008 in Seoul, one the megacities in the Northeast Asia. The retrieved $NO_2$ vertical column densities were compared with those obtained from space borneOzone Monitoring Instrument (OMI). Over the entire measurement period, the $NO_2$ vertical column densities measured by MAX-DOAS ranged from $1.0{\times}10^{15}molec{\cdot}cm^{-2}$ to $6.0{\times}10^{16}molec{\cdot}cm^{-2}$ while those obtained by OMI ranged $1.0{\times}10^{15}molec{\cdot}cm^{-2}$ to $7.0{\times}10^{16}molec{\cdot}cm^{-2}$. The correlation coefficient between $NO_2$ vertical column densities obtained from MAX-DOAS and OMI is 0.73 for the entire measurement period whereas the correlation coefficient of 0.85 is found for the dates under the clear sky condition. The cloudy condition is thought to play a major role in increase in uncertainty of the retrieved OMI $NO_2$ vertical column densities since air mass factor may induce high uncertainty due to the lack of cloud and aerosol vertical distribution information.

A Validation Study on the Reinforcement Effect of Reservoir Grouting by Surface Wave Survey (표면파탐사를 이용한 저수지 제체 그라우팅 보강효과 검증 연구)

  • Bae, Hyungseop;Lee, Yeong-Dong;Won, Kyoung-Sik
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.297-312
    • /
    • 2018
  • In order to assess the safety diagnosis and grouting reinforcement effect of old reservoir facility, local governments and public offices mainly use electrical resistivity survey. However, electrical resistivity survey is a qualitative evaluation that varies the resistivity value by various exploration conditions. It is also difficult to grasp the stiffness change directly related to the stability of reservoir, thus an electrical resistivity survey is not applicable to continuous stability monitoring after grouting. The purpose of this study is to investigate and validate the quantitative evaluation of reinforcement effect of reservoir with cement grouting through shear velocity (Vs), which is closely related to the stiffness (${\mu}$) of the ground. This study was carried out on two reservoir facilities. The reinforcement effect was evaluated by comparing the permeability test, standard penetration test, down-hole test and MASW(Multi-channel Analysis of Surface wave) survey before and after cement grouting. Shear wave velocity changes before and after grouting were analyzed by phase velocity difference and inversion analysis, respectively, and the reliability of the analytical results was evaluated by comparing with field test results. Shear wave velocity increases to 5~10% in case of the D levee, and 10~20% in the levee of H reservoir. These results are showed similar pattern to the field test results.

Ecosystem Structure and Improvement of Naturalness in Urban Area -In the Case of Kangseo-gu in Seoul- (도시생태계 현황파악 및 자연성 증진 방안 -서울시 강서구를 사례로-)

  • 이수동;이경재
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.1-17
    • /
    • 2004
  • The focus of this study is the promotion of green area volumes and their naturalness, water circulation system, decline of entropy, creation of biological habitats and linkage of separated urban green space. Re-presentative urban biotope survey sites were categorized as urban biotope, semi-natural biotope, and natural forest. In the urban biotope, a residential biotope was constructed near the Han river and in mountain areas. The green-area ratio at the housing complex was about 25%. GVZ(Grunvolumenzahl) was 0.35m$^3$/m$^2$ at the 5∼10-story housing complex, and 1.53m$^3$/m$^2$ over the 11-story. As for the green-area structure of the housing complex, canopy layer, understory layer, and shrub layer were not differentiated and the green-area volume was not high enough. The green-area ratio of school areas as a public area biotope was 5∼20%. GVZ was 1.12m$^3$/m$^2$ at Myungduk High School, and 1.78m$^3$/m$^2$ at Jeonggok Elementary School. In order to convert the urban biotope into an ecological area, green areas around the buildings should be connected to urban buffer green areas, and multi-layer structures should be established with natural plant species. In the semi-natural biotope, neighbor parks were created park in the vicinity of the natural forests. GVZ was 0.28m$^3$/m$^2$, and plantation was established with single layer structure and was definitely insufficient for the area. The urban buffer green areas have been established in strip corridors with the width of 20∼123m. In those areas, GVZ was 0.16∼0.27m$^3$/m$^2$ and had a deficient canopy layer, understory layer, and shrub layer. Soil conditions were not favorable for tree growth. In the natural biotope, GVZ of the plantation was 1.03∼1.5m$^3$/m$^2$ but the high crown closure of this area reduces the chance of species change and succession. GVZ of natural forest was 2.53∼2.57m$^3$/m$^2$. It is desirable to plant diverse plants and the natural forest should be succeeded by broad-leaf deciduous tree species. To improve the value of biotope at Kangseo-Gu, building height needs to be limited to reduce the environmental deterioration in the city. In order to maintain the water circulation system, water-permeable material is recommened when the urban surface areas are paved. The establishment of a water circulation system will improve ground water levels, soil moisture, water quality, and habitats. In order to improve biological diversity, it is desirable to have multi-layer structures in urban green areas with native species.

Frequency and Input Impedance Selective Antenna Using Lumped Element for Multi-band Handhold Terminals (집중형 소자를 이용한 공진 주파수 및 입력 임피던스 선택형 다중 대역 튜너블 안테나)

  • Jung, Byung-Woon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.2
    • /
    • pp.50-55
    • /
    • 2008
  • In this paper, multi-band internal antenna which can adjust both resonant frequency and input impedance of antenna as using lumped inductor between shoring plate and ground plane is proposed. The structure of proposed antenna consists of PIFA (Planar Inverted F Antenna) structure and half-wavelength loaded line structure and has two shorting plates and one feeding plate. One shorting plate is shared. The operating frequency bands of designed antenna are GSM, GPS in the PIFA structure and DCS, US-PCS, W-CDMA in half-wave loaded line structure as varying the inductor value in 2.2nH, 3.3nH, and 4.7nH. As varying the inductor value in the shared shorting plate, input impedance of antenna is varied. To minimize the gain variation of antenna as adding lumped element, the inductor value is restricted at maximum of 6.8nH. The maximum gain of proposed antenna is measured as -1.60dBi in the GSM band, -1.16dBi in the GPS band, and 1.41dBi in the DCS/US-PCS/W-CDMA band.

  • PDF

The Design and Fabrication of the Triple-Band Planar Monopole Antenna for Coupled U Patch Line and Rectangular Patch (U자형 패치 라인과 사각 패치를 결합한 삼중 대역 평면형 모노폴 안테나 설계 및 제작)

  • Lee, Sung-Hun;Lee, Seung-Woo;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.745-753
    • /
    • 2011
  • In this paper, the planar monopole antenna for multi-band service is proposed. The proposed antenna, which is a rectangular patch antenna with a U-shaped slit based on a monopole antenna for wide bandwidth characteristic, is designed and analyzed. The antenna size has been miniaturized by using the U-shaped slit. The frequency characteristics are modified and optimized by varying specific parameters. To obtain desired frequency bands, the U-shaped slit and patch lines have been applied. Whole antenna dimensions including the ground plane are $35{\times}50{\times}1\;mm^3$, and the antenna part size is $35{\times}27\;mm^2$. It is fabricated on the FR-4 substrate(${\epsilon}_r=4.4$) using a microstrip line of $50{\Omega}$ for impedance matching. For the measured results, the impedance bandwidth below a VSWR of 2 is 790~916 MHz, 1.74~2.14 GHz, and 2.36~3.13 GHz. The fabricated antenna is satisfied with the aimed impedance bandwidth in GSM/DCS/US-PCS/UMTS/Bluetooth/S-DMB applications.

A Study on the Inter-Relational Interpretation of Street Plant Issues - Focus on Central Park Road in Incheon Metropolitan City - (가로수관련 문제유형의 관계론적 해석 - 인천광역시 중앙공원길을 중심으로 -)

  • Hong, Youn-Soon;Chung, Doo-Yong;Choi, Kang-Rim
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.1
    • /
    • pp.80-89
    • /
    • 2008
  • Generally, trees lining the streets are the most easily accessible green areas in the city and constitute the smallest basic unit in the formation of the urban linear green axis. This study attempts to interpret issues related to city trees from a comprehensive and relational viewpoint. The site of this study is Central Park Street in front of Incheon Metropolitan City Hall. This street is representative of those in Incheon City. This study is an inter-relational interpretation of issues by measuring the vitality of these trees. The following are results of this study: First, the vitality of city trees is higher in those trees growing in natural ground than those growing in plant gratings. This observation can lead to budget savings and increased natural areas in the city. Also, if planter and multi-layering planting methods are introduced where damage to trees is predicted, variation to urban landscape can be achieved while linking to reinforced rearing foundation of street-side trees. Second, there is need for a holistic approach to caring for street-side trees regarding the damage caused by drastic pruning and strong street lights. The typical functions of these trees, like supplying freshness in summer, absorbing solar radiation, and controlling the urban micro-climate are closely related to the vitality of the trees. Accordingly, the function and ecology should be understood holistically, not separately. In this aspect, the functional and ecological use of the multi-layering planting method is effective in protecting pedestrians from vehicles as well. Third, the fallen leaves of monotonous rows of trees have different ecological and functional effects. Not only is the index of greenness in the urban setting increased, but there are also aesthetic and symbolic effects. Fourth, in spite of being the street along which Incheon Metropolitan City Hall, major administrative buildings and Central Park are located, this street does not have its own special identity to discriminate it from other streets. It fulfills only functional criteria based on uniformity. If there is no paradigm shift from today's street system based on vehicles, the role of landscape architecture will be very passive in regards to street-side trees, the minimum unit of urban green. Fifth, on this particular street, many trees were planted in December, which reflects a deficiency of short and long-term strategy, like a street-tree master plan. In this aspect, we still lack a mature culture concerning these trees as a basic unit in urban greenery. Furthermore, there needs to be cultural introspection concerning present administrative practices.

Multi-band directional antenna for satellite communications (위성 통신용 다대역 안테나)

  • Cheong, Chi-Hyun;Jeong, Hye-Mi;Kim, Kun-Woo;Bae, Ki-Hyoung;Tae, Hyun-Sik;Evtyushkin, Gennadiy
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1223-1231
    • /
    • 2010
  • The design is presented for a SATCOM antenna capable of simultaneous multi-band (X/Ku/Ka-Band) communications without replacement of feed horns or change of other parts in the application as a ground satellite terminal for large data transfer. The antenna is the offset configuration and consists of a dual-band(X/Ka-band) feed horn, a single-band(Ku-band) feed horn, a frequency selective surface(FSS) sub-reflector and a parabolic main-reflector. The antenna has a main reflector defining a prime focus and a frequency selective surface sub-reflector defining an image focus. A dual-band feed and a single-band feed are provided at each of the prime focus and image focus. The antenna is designed using 3D EM simulator and the gains measured in X/Ku/Ka-band of the complete antenna assembly is more than 31.6dBi, 36.8dBi, 40.8dBi, and the cross polarization is 21.7dB, 26.6dB, 25.2dB, respectively.

A STUDY FOR THE DETERMINATION OF KOMPSAT I CROSSING TIME OVER KOREA (I): EXAMINATION OF SOLAR AND ATMOSPHERIC VARIABLES (다목적 실용위성 1호의 한반도 통과시각 결정을 위한 연구 (I): 태양 및 대기 변수 조사)

  • 권태영;이성훈;오성남;이동한
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.330-346
    • /
    • 1997
  • Korea Multi-Purpose Satellite I (KOMPSAT-I, the first multi-purpose Korean satellite) will be launched in the third quarter of 1999, which is operated on the sun-synchronous orbit for cartography, ocean color monitoring, and space environment monitoring. The main mission of Electro-Optical Camera(EOC) which is one of KOMPSAT-I sensors is to provide images for the production of scale maps of Korea. EOC collects panchromatic imagery with the ground sample distance of 6.6m at nadir through visible spectral band of 510~730nm. For determining KOMPSAT-I crossing time over Korea, this study examines the diurnal variation of solar and atmospheric variables that can exert a great influence on the EOC imagery. The results are as follows: 1) After 10:30 a.m. at the winter solstice, solar zenith angle is less than $70^{\circ}$ and expected flux of EOC spectral band over land for clear sky is greater than about $2.4mW/cm^2$. 2) For daytime the distribution of cloud cover (clear sky) shows minimum (maximum) at about 11:00 a.m. Although the occurrence frequency of poor visibility by fog decreases from early morning toward noon, its effect on the distribution of clear sky is negligible. From the above examination it is concluded that determining KOMPSAT-I crossing time over Korea between 10:30 and 11:30 a.m. is adequate.

  • PDF

Estimation of Countermeasures and Efficient Use of Volume of Artificial Reefs Deployed in Fishing Grounds (어초어장으로 시설된 사각형어초의 수량 산정 및 유효공용적 평가)

  • Kim, Ho-Sang;Lee, Jeong-Woo;Kim, Jong-Ryeol;Yoon, Han-Sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.181-187
    • /
    • 2009
  • To estimate the status and volume of artificial reefs(ARs) deployed at the sea bottom in fishing grounds, this study assessed the initial volume of ARs, the cubic volume of AR groups, and the porosity of each AR using image data collected during a survey using a multi-beam echo sounder(MBES) and a side scan sonar(SSS). These results were compared with data collected during diver surveys and used to develop a new method and prediction formulas for countermeasures, facility volume, and efficient use of volume for deployed ARs(cubic concrete). The field survey results for nine ARs deployed in the Busan Sea region were calculated, and the average value of coefficient k(indicating the efficient use of volume ratio) among ARs was 0.753, and the correlation between coefficient k and year(Yr) of deployment was calculated as k=0.0023Yr+0.725. The relationship between these two factors was poor. In years following the deployment of artificial reefs, coefficient k and year of deployment were not correlated, in spite of the hardening ground due to subsidence and the reduced distance between ARs. Consequently, it is reasonable to suppose that coefficient k was defined by bottom surface conditions and initial deployment conditions.

  • PDF