• Title/Summary/Keyword: Moving gap

Search Result 164, Processing Time 0.041 seconds

Prebreakdown Corona Discharge of Point-to-Plane Gap in $SF_6$ Gas ($SF_6$ 가스중에서 침대평판간극(針對平板間隙)의 전구(前驅)코로나 방전(放電))

  • Paek, Yong-Hyun;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.980-982
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_6$ gas and prebreakdown growth caused by lightning impulse voltages In inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is observed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrusion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It Is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields and partial discharges in voids.

  • PDF

A theory on the impossibility of the moving for hle and the primary electron as a carrier using the analyses, by quantum mechanics, of the structure of atoms and molecules (양자역학적 원자 및 분자 분석에 의한 정공의 이동 불가능성과 운반자로써의 주도 전자에 관한 이론)

  • 주정규
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.327-330
    • /
    • 1998
  • In this theory, we explained the impossibility of the motion or miving of the hole that has been recognized to be a carrier, by giving some fundamental reasons. We treated energy gap and impurity concentration, in p- and n-type region, as functions of the mobility that is one of te factors which determine current quantity, and analyzed the primary electron theory as a carrier by introducing 2 hypotheses.

  • PDF

Real-Time Response at Motion Control

  • Ha, Young-Youl;Han, Sung-Ho;Woo, Gap-Joo;Kim, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.94.2-94
    • /
    • 2002
  • $\textbullet$ The method to have real-time response at the motion control. $\textbullet$ The trajectory generation method guarantees the continuous acceleration in changing the velocity during the actuator is moving. $\textbullet$ We propose the velocity profile generation algorithm in order to change object position or object velocity with continuous acceleration using blending method.

  • PDF

Hydrodynamic pressure distribution between a piston and cylinder - Experiment (1) (피스톤과 실린더 사이에서의 압력분포-실험(1))

  • 김영환;박태조
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.304-309
    • /
    • 2001
  • In this paper, the hydraulic oil pressure distributions are measured in the clearance gap between a stationary piston and moving cylinder apparatus. The results showed that the hydrodynamic pressure distributions are highly affected by the speed of cylinder and further experimental and analytical studies are required to obtain more accurate results. Therefore present experimental method can be used to enhance the performance of various hydraulic components adopting the piston-cylinder mechanism.

  • PDF

Flow Visualization of Acoustic Streaming Induced by Ultrasonic Vibration Using Particle Imaging Velocimetry (PIV를 이용한 초음파 진동에 의해 유도된 음향유동의 가시화)

  • 노병국;권기정;이장연;이동렬
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.6
    • /
    • pp.528-535
    • /
    • 2004
  • Ultrasonic Vibrator is designed to achieve the maximum vibration amplitude at 30 kHz by in-cluding a horn (diameter, 40 mm), mechanical vibration amplifier at the top of the ultrasonic vibrator in the system and making the complete system resonate. In addition, it is experimentally visualized by particle imaging velocimetry (PIV) that the acoustic streaming velocity in the gap is at maximum when the gap between the ultrasonic vibrator and stationary plate agrees with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave and the theoretical analysis of that is also accomplished and verified by experiment. It is observed that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary plate possibly changes due to the measurement of the average velocity fields of the acoustic streaming induced by the ultrasonic vibration at resonance and non-resonance. There exists extremely small average velocity at non-resonant gaps while the relatively large average velocity exists at resonant gaps compared with non-resonant gaps. It also reveals that there should be larger axial turbulent intensity at the hub region of the vibrator and at the edge of it in the resonant gap where the air streaming velocity is maximized and the flow phenomena is conspicuous than that at the other region. Because the variation of the acoustic streaming velocity at resonant gap is more distinctive than that at non-resonant gap, shear stress increases more in the resonant gap and is also maximized at the center region of the vibrator except the local position of center (r〓0). At the non-resonant gap there should be low values of vorticity distribution, but in contrast to the non-resonant gap, high and negative values of it exist at the center region of the vibrator with respect to the radial direction and in the vicinity of the middle region with respect to the axial direction. Acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover, the proposed method by acoustic streaming can be utilized to the nano and micro-electro mechanical systems as a driving mechanism in addition to the augmentation of the streaming velocity.

Moving Patterns of Patients and Its Implication for Regional Unbalance in Health Resources (환자이동현황을 고려한 병상공급 방향)

  • Yun, Heesuk
    • KDI Journal of Economic Policy
    • /
    • v.29 no.1
    • /
    • pp.41-78
    • /
    • 2007
  • Due to the concern of regional unbalance relating to healthcare resources, the government has set up a plan to expand public healthcare services and a policy to manage the supply of hospital beds. However, it is not clear what standards are needed to measure the degree of unbalance, and to what extent the gap needs to be narrowed. Unlike the previous methodology comparing the proportions of patients who move out from their administrative district to receive medical services, this study examines the inconvenience gap patients experience when they have to move out from their actual living area. The logit and multinomial logit models are employed. The regional unbalance decreases when the degree of movement is measured based on the living area. This result implies that essential standard for achieving regional balance relating to medical services need to be based not on the even distribution of medical resources, but the complications of regional people that require proper medical services.

A High Voltage Poorer Supply for Electrostatic Precipitator with Superimposing Voltage Pulse on DC Source (펄스 및 직류 중첩형 전기집진기용 고전압 전원장치 개발 연구)

  • Kim, Jong-Soo;Rim, Geun-Hie;Lee, Sung-Jin;Kim, Seung-Min;Cho, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.624-630
    • /
    • 2001
  • The trend of the regulations on environmental issues are getting tight. Responding to this trend new technologies such as moving electrodes, wide pitch and pulsed power supply are also introduced in the electrostatic precipitator(EP) systems. The introduction of wide pitch and moving electrodes enhances the system performance of the EPs by improving air-flow and by improving the ash reentrainment on rapping. The power supplies for the EPs developed up to date include thyristor-based dc or intermittent type, SMPS(switching mode power supply) type and the pulsed-power supply type. The use of the pulsed ones is known to improve dust-collecting efficiency of high resistivity ash and reduces back corona occurrence in the collecting plate. There are two kinds of pulsed-power supplies; one with pulsed transformers and the other with direct dc switching devices. The latter uses rotary spark gap switches or semiconductor switches. Both have the merits and demerits: the spark gap switches are simple and robust but has short life time, hence, high maintenance cost, whereas the semiconductor switches have long life time but are costly. In this study, A high voltage power supply with superimposing voltage pulse on dc source was developed for EPs. This study describes circuit topology, operating principle of the scheme, and analysis of experimental results on Dong-Hae Power Plant. The pulsed power supply consists of a variable dc power supply with ratings of 60kV, 800mA and pulse generator which is made of high voltage thyristor-diode switch strings, an LC resonant tank and a blocking inductor. The pulse generator generates variable pulse-voltage up to 70kV using a high frequency resonant inverter with a variable dc source. Two prototypes were built and tested on 250MW DongHae power plant to verify the possibility of the commercial use and the normal operation in the transient states.

  • PDF

Gap arthroplasty with active mouth opening exercises using an interocclusal splint in temporomandibular joint ankylosis patients

  • Park, Min Woo;Eo, Mi Young;Seo, Bo Yeon;Nguyen, Truc Thi Hoang;Kim, Soung Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.18.1-18.10
    • /
    • 2019
  • Background: Temporomandibular joint (TMJ) ankylosis during early childhood may lead to disturbances in growth and facial asymmetry and to serious difficulties in eating as well as in breathing during sleep. The purpose of this study is to describe the effectiveness of an interocclusal splint (IOS) for active mouth opening exercises in the treatment of TMJ ankylosis. Methods: A total of nine patients with 13 instances of TMJ ankylosis from 2008 to 2010 were included in this study, of which five patients were male and four patients were female. Five patients demonstrated unilateral ankylosis, while five patients showed bilateral symptoms. Ankylosed mass resection with coronoidectomy, fibrotic scar release, and resection of stylohyoid ligament calcification was performed with gap arthroplasty without an interpositional graft, and all patients were assessed for maximum mouth opening (MMO) during a mean 6.6-year follow-up period. Results: All patients were subjected to postoperative mouth opening exercises from the day of the operation with the help of an IOS, which was based on an impression taken during surgery. All patients were sufficiently comfortable moving their mandible according to the IOS's guiding plane and impingement, and satisfactory results were achieved, in which MMO was improved by 35 mm more than 6 years after surgery. Conclusions: Complete and adequate resection of the ankylosed mass and postoperative active mouth opening exercises are essential in the treatment of TMJ ankylosis. Moreover, a more comfortable mouth opening guide and interdigitation can be achieved using an IOS, and newly organized fibrosis in the gap space between the newly made resected condylar head and temporal fossa can be suggested.

Technology Gap Prediction and Technology Catchup Strategy for High-Speed Rail Vehicles (고속철도차량의 기술격차 예측과 기술추격 전략)

  • Kim, Hyung Jin;Kim, Si Gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.131-138
    • /
    • 2023
  • This study started with questioning the fact that in the assessmentof technology, which has taken place every two years since 2010, the technology gap in the most technologically advanced countries was evaluated as 4-5 years in each evaluation. To interrogate this question, regression estimation was performed using the Gompertz model based on time series data for technology level evaluation. As a result, it would take 17 years for high-speed rail vehicle technology to reach the level of 95 % of the country with the highest technology, and 72 years to reach the level of 100 %. Recognizing the technology gap is important in establishing a technology catchup strategy. A collaborative technology catchup strategy is the best strategy for moving to an original technology development stage while competing with large global leaders without much domestic market demand. This can occur regardless of where Korea is located in the technology catchup stage.

Numerical study for fluid-structure interaction of blood flow in TPLS (박동형 인공심폐기에서의 혈류의 고체-유체 상호작용에 대한 수치적 연구)

  • Jung G. S.;Seong H. C.;Shim E. B.;Ko H. J.;Min B. G.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.705-706
    • /
    • 2002
  • Hemodynamics of the TPLS(Twin Pulse Life Support System) is numerically investigated to delineate the possibility of hemolysis in blood. Computational method employing finite element algorithm is utilized to solve the blood flow of the sac squeezed by moving actuator. We assume that the blood flow interacts with the sac material which is activated by the rigid body motion of the actuator. Valve dynamics at the ends of the sac is simplified as on/off type motion. We compute the transient viscous flow in the two-dimensional geometry of the blood sac. Incompressible laminar flow is simulated on the assumption of Newtonian fluid. Blood velocity has a step gradient near the throat of the sac formed by the moving actuator. According to the decrease of the gap size of blood passage, the magnitude of shear stress in the blood is dramatically increased. Numerical solutions show that the maximum value of shear stress in the blood flow in TPLS is relatively smaller than that of the roller type ECLS.

  • PDF