• Title/Summary/Keyword: Movement Pattern Analysis

Search Result 372, Processing Time 0.028 seconds

Optimal Provider Mobility in Large-Scale Named- Data Networking

  • Do, Truong-Xuan;Kim, Younghan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.10
    • /
    • pp.4054-4071
    • /
    • 2015
  • Named-Data Networking (NDN) is one of the promising approaches for the Future Internet to cope with the explosion and current usage pattern of Internet traffic. Content provider mobility in the NDN allows users to receive real-time traffic when the content providers are on the move. However, the current solutions for managing these mobile content providers suffer several issues such as long handover latency, high cost, and non-optimal routing path. In this paper, we survey main approaches for provider mobility in NDN and propose an optimal scheme to support the mobile content providers in the large-scale NDN domain. Our scheme predicts the movement of the provider and uses state information in the NDN forwarding plane to set up an optimal new routing path for mobile providers. By numerical analysis, our approach provides NDN users with better service access delay and lower total handover cost compared with the current solutions.

Designing Real-time Observation System to Evaluate Driving Pattern through Eye Tracker

  • Oberlin, Kwekam Tchomdji Luther.;Jung, Euitay
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.421-431
    • /
    • 2022
  • The purpose of this research is to determine the point of fixation of the driver during the process of driving. Based on the results of this research, the driving instructor can make a judgement on what the trainee stare on the most. Traffic accidents have become a serious concern in modern society. Especially, the traffic accidents among unskilled and elderly drivers are at issue. A driver should put attention on the vehicles around, traffic signs, passersby, passengers, road situation and its dashboard. An eye-tracking-based application was developed to analyze the driver's gaze behavior. It is a prototype for real-time eye tracking for monitoring the point of interest of drivers in driving practice. In this study, the driver's attention was measured by capturing the movement of the eyes in real road driving conditions using these tools. As a result, dwelling duration time, entry time and the average of fixation of the eye gaze are leading parameters that could help us prove the idea of this study.

Analysis of individual hand movement patterns of hand disorder patients using smart gloves (스마트 글러브를 이용한 손 마비환자 개인별 손 움직임 패턴 분석)

  • Hwang, Youngah;Moon, Mikyeong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.07a
    • /
    • pp.381-382
    • /
    • 2020
  • 우리나라의 손 마비환자의 수는 매년 증가하고 있다. 병원에서 진행하는 일반적인 재활치료는 비용이 많이 들기 때문에 손 마비환자가 가정에서 재활운동을 하는 경우가 많아지고 있다. 본 논문에서는 손 마비환자들이 가정에서 재활운동을 할 시, 개인별 맞춤 케어를 제공해주기 위하여 스마트 글러브를 이용한 개인별 움직임 패턴을 분석하는 방법에 대해 기술한다. 손 마비환자는 움직임 패턴 분석을 통해 자신의 각 손가락 마비 정도를 정확히 인지할 수 있게 될 것으로 기대한다.

  • PDF

A CONFUTER ANALYSIS ON THE ARTICULAR EMINENCE AND THE CONDYLAR PATH OF THE EDENTULUS PATIENT IN MANDIBULAR PROTRUSIVE MOVEMENT (무치악자의 하악전방운동시 관절융기와 과두운동로에 관한 컴퓨터 분석)

  • Lee Yeoun-Soo;Park Nam-Soo;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.321-337
    • /
    • 1992
  • The objective of this study was to compare the condylar path and the anterior angle of articular fossa and to analyze the pattern of condylar path in edentulus patients. Nineteen male and female edentulous patients with normal masticatory system ranging in age 42 to 78, without present symptoms and any history of TMJ disturbance were selected for this study. On the computer analysis on the transcranial radiographs of the TMJ, the angle of slope of articular eminance and condylar path to the Frankfort Horizontal Plane and the height of glenoid fossa was measured respectively, and stuied their interrelationship comparatively. Obtained results were asfollows. 1. The angle of the slope of articular eminence averaged 37.28 degree. and there was no significant difference between the right and left side. 2. The condylar path angle averaged 29.05 degree and there was no significant difference between the right and left side. 3. The height of the glenoid fossa averaged 8.11 mm and there was no significant difference between the right and left side. 4. The sequence of the frequence of condylar movement patterns were concavex curve(39.5% ), 'S' shape curve(34.2%), reverse 'S' shape(15.8%) and convex curve(10.5%). 5. The horizontal distance of the point of the changed curve of the condylar path averaged 2.91 mm. 6. The height of glenoid fossa was highly correlated to the slope of articular eminence and relatively highly correlated to tile condylar path and the condylar path was closely correlated to the slop of articular eminence.

  • PDF

Comparison of Muscle Thickness and Changing Ratio for Cervical Flexor Muscles During the Craniocervical Flexion Test Between Subjects With and Without Forward Head Posture

  • Lee, Jae-hyun;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.180-186
    • /
    • 2022
  • Background: The craniocervical flexion test (CCFT) was developed for the activation and endurance of deep cervical flexors. However, the muscle thickness and muscle thickness changing ratio of the sternocleidomastoid (SCM) and deep cervical flexor (DCF) muscles in subjects with and without forward head posture (FHP) have not been reported. Objects: To determine the difference in thickness of the SCM and DCF muscles and the difference in the muscle thickness changing ratio between SCM, DCF, and DCF/SCM 20 mmHg and DCF/SCM 30 mmHg between subjects with and without FHP. Methods: Thirty subjects with and without FHP were enrolled. The muscle thickness of the SCM and DCF was measured when maintained at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg using a pressure biofeedback unit during the CCFT. Ultrasonography was used to capture images of SCM and DCF muscle thickness during the CCFT, which was calculated using the picture archiving and communication system (PACS). Results: We observed a significant difference within the pressure main effect between SCM and DCF at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg (p < 0.05). However, there was no significant difference in the muscle thickness and muscle thickness changing ratio for SCM and DCF during CCFT between subjects with and without FHP. Conclusion: There was no significant difference in the muscle thickness recruitment pattern during CCFT in posture changes between subjects with and without FHP.

Study of screw loosening in cementation type implant abutment

  • Hwang, Bo-Yeon;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.765-781
    • /
    • 2000
  • The purpose of this study was to compare the screw loosening characteristics of three avail-able cementation type abutments: one-piece cementation type abutment; two-piece cementation type abutment using titanium abutment screw; two-piece cementation type abutment using gold abutment screw. Two implant supported three-unit superstructures were fabricated using a pair of 3 kinds of abutments for each experimental model. Cyclic loading was applied on the specimen, and made to stop when the superstructure showed movement over threshold range. The loaded cycle was counted until the machine stopped. Frequency analysis was done to measure the change of natural frequency before and after the application of cyclic load and to find the effect of screw loosening on the change of natural frequency. The specimen assembly was modeled to perform the finite element analysis to see the distribution of the stress induced by the application of preload over the screw joint and to compare the pattern of the distribution of stress induced by the external force with the change of the preload condition. The following results were obtained: 1. The failure loading cycle of two-piece cementation type abutment using gold screw was significantly greater than those of the other groups. 2. One-piece cementation type abutment applied to multi-unit restoration case did not show greater resistance to screw loosening compared to two-piece cementation type abutments. 3. Frequency analysis showed decrease in natural frequency when screw loosening occured.

  • PDF

Analysis of occlusal contact and guidance pattern during maximal intercuspal position and protrusive movement (최대교두감합위 및 하악 전방운동 시의 교합접촉 및 교합유도 양상에 관한 분석)

  • Kim, Jiyeon;Kim, Kang-Hyun;Noh, Kwantae;Kim, Hyeong-Seob;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • Purpose: The importance of occlusal contacts of the natural dentition for durability of teeth, mandibular stabilization, and restorative dentistry is well known. The purpose of this study is to analyze the occlusal contact and guidance pattern of Koreans by evaluating the static occlusion on maximal intercuspal position and measuring dynamic occlusion during straight protrusion. Materials and methods: The occlusal contacts at maximal interincisal position and the occlusal guidance pattern during straight protrusion of 29 subjects were recorded with shimstock foil (Whaledent, Langenau, Germany), T-Scan III (Tekscan Inc., Boston, MA, USA), polyvinylsiloxane registration material (Genie Bite, Sultan Healthcare, Hackensack, NJ, USA) and compared. Occlusal registration procedures were repeated 3 times. The position was fixed to an upright position and the head position was fixed with the Frankfurt horizontal plane paralleling the horizontal plane. Fisher's Exact Test (R-General Public License, ver. 2.14.1) and Pearson's Test were used to assess the significance level of the differences between the experimental groups (${\alpha}=.05$). Results: When using shimstock foil, T-Scan III system, and polyvinylsiloxane registration material, most of the patients showed contact on anterior, premolar, and molar teeth during maximal intercuspal position. Approximately 51% of maximal intercuspal position showed anterior contact using shimstock foil. When examining the protrusive movement using shimstock foil and T-Scan III system, guidance pattern with the central incisor was the most common. Conclusion: During maximal intercuspal position, there were cases in which not all of the teeth showed occlusal contact. During mandibular protrusive movements, one or more maxillary central incisors frequently joined in straight protrusion and the posterior teeth were disoccluded. Therefore, the anterior teeth protect the posterior teeth, and vice versa. Thus, mutually protected occlusion should be applied when reconstructing occlusion.

A 3-D finite element analysis on the mandibular movement pattern and stress distribution during symphyseal widening (하악 이부확장 시 하악골 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Lee, Do-Hoon;Hong, Hyun-Sil;Chae, Jong-Moon;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.13-30
    • /
    • 2008
  • Objective: The objective of this study was to evaluate the displacement pattern and the stress distribution of the finite element model 3-D visualization during symphyseal widening according to the osteotomy position, osteotomy type, and distraction device. Methods: The kinds of distraction devices used were tooth-borne type, hybrid type, bone-borne type and tooth-borne type $30^{\circ}$ angulated, and the kinds of osteotomy design were vertical osteotomy line between the central incisors and step osteotomy line through the symphysis. Results: All reference points of the mandible including the condyles were displaced laterally irrespective of the osteotomy position, osteotomy method and distraction device. The anteroposterior or vertical displacements showed small differences between the groups. The widening pattern of the osteotomy line in the tooth-borne type of device was v shaped, and that of bone-borne type was a reverse v shape. However, the pattern in the hybrid type was parallel. The lateral displacement of the mandibular angle by the bone-borne device was more remarkable than the other types of devices. The displacement by the $30^{\circ}$ angulated tooth-borne type was different between the left and right sides in both the transverse and anteroposterior aspects. Conclusion: The design of the distraction devices and osteotomy line can influence the displacement pattern and the stress distribution during mandibular symphyseal distraction osteogenesis procedures.

Pattern Analysis of Occlusal Contacts During Lateral Excursion Using T-scan III System (T-scan III 시스템을 이용한 하악 측방운동 시 교합접촉 양상의 분석)

  • Lee, Sang-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.59-68
    • /
    • 2013
  • The objective of this study was to analyze occlusal contact pattern of 33 young adult males with normal occlusion during lateral excursion using T-scan III system which can measure the dynamic occlusion. Occlusal contact patterns were examined and categorized in non-working side disclusion point(more functionally acceptable position) not canine-to-canine position. Disclusion time, occlusal force, and occlusal force distribution ratio of upper canine at disclusion point during lateral excursion movement was also measured and compared among the groups divided according to contact patterns. The results showed that group function was clearly more dominant than canine guidance and other occlusal contact patterns different with existing patterns were found. There were significantly difference between groups in variables of T-scan measurement. T-scan III system is effective tools to analyze and evaluate occlusal contact patterns, disclusion time, occlusal force, and occlusal force distribution ratio of upper canine at disclusion point.

Effect of Proprioceptive Neuromuscular Facilitation Applied to the Unilateral Upper Extremity on the Muscle Activation of Contralateral Lower Extremity (펀측 상지에 적용된 고유수용성 신경근 촉진법이 반대측 하지의 근 활성도에 미치는 영향)

  • Kim, Kyung-Hwan;Park, Ji-Won;Bae, Sung-Soo
    • PNF and Movement
    • /
    • v.4 no.1
    • /
    • pp.9-18
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effect of Proprioceptive Neuromuscular Facilitation (PNF) applied to the unilateral upper extremity on the muscle activation of contralateral lower extremity. Twenty-two healthy subjects (mean age of 23.7 years) participated in this study. Method : PNF patterns applied on the unilateral upper extremity in all subjects were the flexion/abduction/external rotation and lifting pattern. The hold and appoximation techniques for the irradiation were applied to end range of both patterns. Muscle activations in four patterns were measured in vastus medialis, tibialis anterior, rectus femoris, and gastrocnemius medial muscles of contralateral lower extremity using surface EMG system. Each EMG value in individual muscle was normalized for maximal voluntary contraction. The data were analyzed by one factor analysis of variance with repeated measure test. Result : There were significant differences in the between-subject effect (muscles) and within-subject effect (patterns) in comparison of muscle activation by application of PNF patterns (p<.05). The irradiation led to higher activation in the flexion/abduction/external rotation pattern than that of lifting pattern in all muscles (p<.05). The approximation techniques revealed more activations than these of hold technique in all muscles (p<.05). Conclusion : These results suggest that the application of PNF patterns to the unilateral upper extremity affect on the muscle activation of contralateral lower extremity and increase according to the intensity of resistance. This mechanism of contralateral effect might provide a help to the development of treatment method for the affected side and functional improvement for the patients who have damages of central nervous system or musculoskeletal problems by orthopedic injury.

  • PDF