• 제목/요약/키워드: Movement Pattern

검색결과 1,137건 처리시간 0.024초

유아와 성인의 보행 특성 비교 (Comparative gait characteristics of infant and adults)

  • 장윤희;양길태;임송학;문무성;이경옥;김미예
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.86-87
    • /
    • 1998
  • To understand the developmental process of the gait pattern from infancy to the adult, a gait analysis for a 14 months female infant has been performed for ten weeks. The gait parameters has been measured every other week since the week when she was able to walk without aid. The infant gait data at the tenth week of the test shows a similar pattern to the adult gait in many aspects including initial knee flexion, initial ankle dorsiflexion, the push-off pattern, etc. There is not a significant change in the hip flexion angle from week to week from the two weeks after the test started. To check the individuality in the collected data, more infant subjects are being tested presently.

  • PDF

광위상 간섭을 이용한 이송축의 운동오차 실시간 보상 (Real-Time Correction of Movement Errors of Machine Axis by Twyman-Green Interferometry)

  • 이형석;김승우
    • 대한기계학회논문집
    • /
    • 제17권12호
    • /
    • pp.3115-3123
    • /
    • 1993
  • This paper presents a real-time correction method of the movemont errors of a translatory precision machine axis. This method is a null-balances technique in which two plane mirrors are used to generate an interferometric fringe pattern utilizing the optical principles of TwymanGreen interferometry. One mirror is fixed on a reference frame, while the other is placed on the machine axis being supported by three piezoelectric actuators. From the fringe pattern, one translatory and two rotational error components of the machine axis are simultaneously detected by using CCD camera vision and image processing techniques. These errors are then independently suppressed by activating the peizoelectric actuators by real-time feedback control while the machine axis is moving. Experimental results demonstrate that a machine axis can be controlled with movement errors less than 10 nm in vertical straightness, 0.1 arcsec in pitch, and 0.06 arcsec in roll for 50mm travel by adopting the real-time correction method.

편마비환자의 환측 하지 외회전 정도가 기립균형에 미치는 영향 (Influence of Standing Balance With External Rotation Angle of the Hemiplegia Leg)

  • 이동욱;곽길환;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제15권3호
    • /
    • pp.173-188
    • /
    • 2003
  • The two groups each consisting of 28 people who had an adult hemiplegia due to a brain injury received two different methods of exercises to reduce the angle to which the affected lower limb rotates externally. The comparisons between the two groups were made for the changes of the angle in external rotations measured between pre and post test. The static balance index values taken during pre and post tests were also compared. In addition, the correlations of the angle to which the affected lower limb rotates externally with static balance index values were analyzed. The result were as follows: 1. A statistical analysis indicated that in group one having taken simple R.O.M exercises, the angle to which the affected lower limb rotates externally and the static balance index values were both significantly different between pre and post test (P<.01). 2. A statistical analysis indicated that in group two having taken a pattern movement, both the angle to which the affected lower limb rotates externally and static balance index values were significantly different between pre and post test (P<.01). 3. A significant difference between simple R.O.M exercises group and pattern movement exercises groupwas shown only for the angle to which affected limb rotates externally not for static balance index values (P<.01), 4. Pearson correlation coefficient for the angle to which the affected limb rotates externally with static balance index values was found to be significant only in pattern movement exercises group (P < .05).

  • PDF

일일 인구이동으로 본 국토공간의 도시체계 변화: 2005년과 2012년 (The Changes of Urban System Reflected in Daily Movement: 2005-2012)

  • 손승호
    • 대한지리학회지
    • /
    • 제50권2호
    • /
    • pp.203-216
    • /
    • 2015
  • 본 연구는 일일 인구이동에 의한 네트워크와 유동패턴을 통해 한국의 도시체계 변화를 고찰하였다. 일일 인구이동이 일상적인 통행패턴을 반영하므로, 도시간 연결관계에 의한 도시체계는 생활권의 관점으로 인식할 수 있다. 2012년 들어 도시간 인구이동이 증가하면서, 도시 네트워크의 연결체계를 비롯하여 출발지와 도착지로 구성되는 통행권의 수가 모두 증가하였다. 통행량의 분산에도 불구하고 서울을 중심으로 하는 수도권과 부산을 중심으로 하는 부산권의 공간범위는 확대되었다. 서울지향형 고속교통망이 구축된 강원도에서는 춘천을 중심으로 하는 소양강문화권과 영동지방의 생활권 분리가 심화되었다. 교통망의 접근성이 양호한 대전과 그 주변지역을 아우르는 생활권은 경기남부까지 확대되었다. 전남에 형성된 기존의 생활권은 광주의 중심성이 약화되면서 목포와 순천을 중심으로 서부와 동부에서 분절되었다. 생활권은 거시적으로 광역 행정경계와 대체로 일치하였지만, 도 경계를 넘어 다른 광역단체의 시군과 통합되는 사례가 증가하였다. 서울과 그 주변 도시간의 상호작용이 강화된 것은 서울을 중심으로 하는 세계도시-지역의 발전 가능성을 높여준다.

  • PDF

동작성 향상을 위한 비행복의 패턴개선 및 평가 (The Improvement and Evaluation of the Flight Suit Pattern to Enhance Movement)

  • 전은진;박세권;유희천;김희은
    • 한국의류산업학회지
    • /
    • 제12권5호
    • /
    • pp.633-641
    • /
    • 2010
  • The purpose of this study is to evaluate a new flight suit in bilateral ways; subjectively and objectively in the improvements of comfort and mobility. Seven healthy males at the age of twenties volunteered in this wearing test. They were over 177 cm in height and 92-95 cm in chest circumference, which satisfies the M95 Special' size described in the Korean Military Specifications and Standards. The subjective satisfaction was evaluated according to the criteria of ease of donning and doffing, fitness of wear, mobility, space between cloth and body, convenience in using restroom. Subjective satisfaction evaluation says that the best improvement of movement are neck circumference, chest breadth, armscye circumference, waist back length, crotch length, crotch height and body rise. According to the evaluation, improvements of mobility were conspicuous especially in parts of body like neck, breast, waist, back, and arms. When evaluating objective satisfaction, we measured a angle difference in a prescribed standard-grid on a photograph that picked up while the subject performed each motion in front of 10 cm-interval grid. As a result, the motion that had angle difference above 5 degrees were arm stretching and standing on single leg holding at forward or at his side. Bending necks and waist, crouching also had angle difference of over 5 degrees. The improvements are discussed from the viewpoint that the increased ease in parts of armscye circumference and crotch in new flight suit pattern.

유리단 국소의치의 지대치 운동에 관한 생체학적 연구 (IN VIVO STUDY ON ABUTMENT TOOTH MOVEMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURES)

  • 이종엽;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.43-61
    • /
    • 1990
  • The laser reflexion method is a new technique which permits precise contactless measurement and observation of tooth mobility as well as tooth movement. The purposes of this study were to clarify the reliability of the laser reflexion method in clinical application and to measure the abutment tooth movement according to clasp design. This study was designed to determine 1) How much a bending movement of the impression plate stand affects the position of the reflexion pattern and how precise the patient bites into plate 2) Which clasp design causes greater movement of the abutment tooth. Under medium and maximum bite forces, tests were performed on central loading position which was 13mm distal to terminal abutment tooth of distal extension removable partial denture. The movement in the mesiodistal and buccolingual directions was measured. The Duncan's New Multiple-Range test was used to compare the means for the four castings under each direction-load combination; and the paired sample t-test was for medium and maximum bite forces. From this experiment, the following results were obtained. 1. The Roach clasp, the combination clasp, the RPI clasp, and the Akers clasp did not significantly differ in their effects on buccolingual movement of the abutment tooth. 2. The direction of abutment tooth movement was not significantly altered by clasp design and all abutment tooth movements were oriented distobuccally. 3. Under medium bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the combination clasp and the RPI clasp. Under maximum bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the RPI clasp. 4. The testing apparatus and procedures used in this study(laser reflexion method) proved to be reliable in clinical application.

  • PDF

유창성과 비유창성 화자의 발성 종결-개시 차이에 관한 예비연구 (A Preliminary Study on Differences of Phonatory Offset-Onset between the Fluency and a Dysfluency)

  • 한지연;이옥분
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2006년도 춘계 학술대회 발표논문집
    • /
    • pp.109-112
    • /
    • 2006
  • This study investigated the acoustical characteristics of phonatory offset-onset mechanisms. And this study shows the comparative results between non-stutterers (N=3) and a stutterer (N=1). Phonatory offset-onset means a laryngeal articulatory in the connected speech. In the phonetic context V_V), pattern 0(there is no changes) appeared in all subjects, and pattern 4(this indicate the trace of glottal fry and closure in spectrogram)was only in a Stutterer. In high vowels(/i/, /u/), pattern 3 and 4 appeared only in a stutterer. Although there is no common pattern among the non-stutterers, individual's preference pattern was founded. This study offers the key to an understanding of physiological movement on a block of stutter.

  • PDF

평지와 고르지 않은 지면 경사로 보행 시 고령자와 젊은 성인의 운동학적 요인 비교 (Comparison of Kinematic Factors between Old and Young People during Walking on Level and Uneven Inclined Surfaces)

  • 최진승;강동원;문경률;방윤환;탁계래
    • 한국운동역학회지
    • /
    • 제20권1호
    • /
    • pp.33-39
    • /
    • 2010
  • The purpose of this study was to investigate the changes in walking pattern of the elderly during inclined walkway with uneven surfaces and level walking. 10 young($26.3{\pm}1.3$ years, $174.3{\pm}5.3\;cm$, $69.5{\pm}9.5\;kg$) and 13 elderly($72.4{\pm}5.2$ years, $164.5{\pm}5.4\;cm$, $66.1{\pm}9.6\;kg$) male subjects were participated in the experiment. Experiment consisted of 2 walking conditions: horizontal and inclined walkway with uneven surfaces. 3D motion capturing system were used to acquire and analyze walking motion data with sampling frequency of 120 Hz. To compare differences between conditions, kinematic variables(walking speed, stance-swing ratio, hip joint angle, knee joint angle, ankle joint angle, pelvic rotation angle) were used. Results showed that there were some changes of elderly walking pattern in inclined walkway with uneven surfaces: hip joint(adduction and rotation) and pelvic movement pattern. These changes by inclination and surface may affect gait pattern of young subjects as well as elderly subjects. However, in case of elderly it revealed more unstable gait than the young. Further study is necessary to clarify changes in walking pattern for elderly by considering various gait variables including head movement and various walkway conditions.

인체 근육 위치에 기초한 40대 남성을 위한 컴프레션 웨어 상의 개발 (Development of Compression Wear Tops for Men in Their Forties Based on Muscle Locations)

  • 이정화;전정일;최경미
    • 한국의류학회지
    • /
    • 제39권2호
    • /
    • pp.271-286
    • /
    • 2015
  • This study presented functional designs for development of functional compression wear for men in their forties based on body muscles as well as designed 2D patterns using 3D standard body form data of men in their forties. Patterns with an optimal stretch rate were proposed through a comfort evaluation. Different material was used for different areas such as the sports ability strengthening areas including body parts that often move for sports (such as the shoulders, abdomen and lower arm), areas that require ventilation for perspiration (such as the chest and back center, and armpits), and stable form areas (such as the chest, waist and elbows). The front and back surface areas of the developed pattern was an average 102.4% size compared to the body surface area. The results indicated that the 90% reduction pattern showed changes in pressure value according to area of movement, had the best breathability when worn, and had the best, most comfortable fit compared to the other subjects. The clothing pressure values of the pattern were around 22.1-23.4mmHg for the arm area (which has a big movement range and has many muscles) and 10.4-11.8mmHg for chest and abdomen areas related to major organs and breathing, indicating appropriate clothing pressure. A compression wear top pattern with pressure appropriate to the target age range and excellent appropriateness for the body form will be developed for men in their forties. A study method will be proposed to develop design technology for ergonomic compression wear tops with excellent fit and comfort.

인공신경망모형을 이용한 주가의 예측가능성에 관한 연구

  • 정용관;윤영섭
    • 재무관리연구
    • /
    • 제15권2호
    • /
    • pp.369-399
    • /
    • 1998
  • 주가가 과연 예측가능한가의 여부는 이론적으로나 실무적으로 매우 중요한 의미를 가져 이 부분에 대해 많은 연구가 이루어져 왔으나 많은 기존연구들은 주가가 예측 가능하다는 결론을 얻지 못하고 있으며, 예측 가능하다는 연구에서도 예측력이 크지 않게 나타나고 있다. 이러한 실증결과는 실증모형의 선택이 적절하지 못한데서 나타날 수 있다는 가능성을 배제할 수 없다. 기존연구들이 실증분석에서 선형모형을 사용했는데, 선형모형으로는 주가의 예측가능성을 정확히 검증하기 어려운 현실적 요인들이 존재할 수 있다. 증권시장에는 시장실패를 방지하기 위한 규제나 제도 및 시장의 불완전성으로 인해 주가움직임에 선형모형으로 추정하기 어려운 특이패턴이 발생할 수 있기 때문이다. 이 논문에서는 이러한 특이패턴이 존재한다는 가능성을 전제로 비모수적 모형, 그 중에서도 인공신경망모형을 이용하여 주가예측 가능성을 재검증해 보고자 한다. 특히 인공신경망모형을 이용한 예측성과를 동일한 구조를 가지는 선형모형의 성과와 비교함으로써 특이패턴의 고려가 주가예측에 어떤 개선을 제공할 수 있는지를 검증해 보고자 한다. 분석결과를 요약하면, 인공신경망모형이 예측력을 가질 수 있으며, 특히 유사한 구조를 가지는 선형모형보다 우월한 성과를 제공할 수 있다는 가능성을 발견하였다. 이는 선형모형으로 추정하기 어려운 특이패턴이 주가움직임에 존재하며, 따라서 이러한 패턴을 반영할 수 있는 인공신경망모형이 주가예측에 유용하게 사용될 수 있다는 것을 보이는 결과라 볼 수 있다.

  • PDF