• Title/Summary/Keyword: Motor starting

Search Result 410, Processing Time 0.025 seconds

Selection of Motor Starting Method by Numeric Simulation (기동시뮬레이션 방법에 의한 유도전동기 기동방식 선정)

  • Chang, Chung-Koo;Suh, Sang-Jin;Lee, Min-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.817-820
    • /
    • 2002
  • Since a squirrel cage induction motor by NEMA Design types is designed to withstand full-voltage starting, direct starting method can be the most economical one. Starting a squirrel cage motor from standstill by connecting it directly across the line may allow inush currents of approximately 500-600% of rated current at lagging power factor of 35-50%. For many of the large motors, the starting inrush current may be great enough to cause voltage dips, which may adversely affect the building's lighting system. Electric utilities also have restrictions on starting currents, so that voltage fluctuations can be held to prescribed limits. Therefore the need for choosing the most appropriate method of motor starting is quite essential. In this paper, we proposed a plan for the selection of the most appropriate motor starting method, first by way of numeric simulation using manufacturer's data and second by way of actual experience. So far, more often than not, the selection of motor starting method has been accomplished only as regards to the capacity of the motor and the frequency of starting and stopping. But nowadays such high-tech apparatus as soft starters are being developed, and we are on the position to give more attention to clarify the way of selection of the motor starting method.

  • PDF

A Study on Improving High-Power Induction Motor Starting (대용량 유도전동기 기동 개선에 관한 연구)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.178-184
    • /
    • 2016
  • The motor power of the industry to use the electric energy is gradually increased. The electric motor generates a voltage drop in the starting current during startup. The starting current is started it is difficult to have an adverse effect on neighboring power systems with large motor starting when the voltage drop across the power grid. In addition to that the motor torque according to the load depending on the size of the rotation speed is changed to a motor start-up speed is important. However, the distance to the emergency generator transformers or motors from the motor capacity is smaller but short and difficult to maneuver the theory and practice of the operating characteristics of the starting characteristics of the motor used a lot of large industrial plants were measured and analyzed. Therefore, this study investigated the motor starting Analysis and interpretation for the relationship with the large motor starting torque and speed during motor starting.

Excessive Condition Interpretation of a Exciter Circuit to Prevent Starting Failure of Large Synchronous Motor (대형 동기 전동기 기동실패방지를 위한 여자기회로 과도현상 해석)

  • Park, Jin-Hun;Cho, Ne-Su;Kwon, Woo-Hyen;Im, Soung-Hun;Yoon, Kyoung-Seop;Kim, Woo-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.739-740
    • /
    • 2006
  • According to the rapid growth of high speed and precise industry, the application of synchronous motor has been increased. In the application fields, the large synchronous motor is not a self-starting motor. The rotor is heavy and, from a dead stop, it is impossible to bring the rotor into magnetic lock with the rotating magnetic field for this reason, all synchronous motor have some kinds of starting device. A simple starter is another motor which brings the rotor up to approximately 96 percent of it synchronous speed. The starting motor is disconnected and the rotor locks in step with the rotating field. The more commony used starting method is to have the rotor to include a squirrel cage indution winding. This indution winding brings the rotor almost to synchronous speed as an induction motor. So, this paper describes excessive condition interpretation of a exciter circuit to prevent starting failure of large synchronous motor. the large synchronous motor needs safety of it in accordance with operating frequent start and stop. the operating Problem point of synchronous motor appears potential element damage of Exciter circuit because synchronous motor is caused synchronous separation. hence we eliminate it and improve starting toque.

  • PDF

Starting Characterization of Induction Motor using Reactor Tap Change (리액터 탭 절환에 의한 유도전동기의 기동 특성)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • An induction motor is most widely used to obtain driving force in the industrial field. The induction motor is generated a high current at starting. A starting current is often more than five times of rated current. A high starting current can cause problems such as voltage drop in the power system. In order to solve these problems, a reactor starting method has been widely applied in a large motor capacity. There are differences in the operating characteristics of induction motor corresponding the switching time of reactor tap. In this study, I analyzed that current, torque, power of induction motor are different from changing time and tap setting values of reactor tap.

Numerical Analysis on Flow Characteristics of Air Starting Motor for Marine Medium-Speed Diesel Engine (선박용 중형디젤엔진 공기시동모터의 유동특성에 관한 수치해석)

  • Yang, Su-Young;Kim, Tae-Hun;Lee, Yeon-Won;Doh, Deog-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.545-552
    • /
    • 2009
  • The marine medium-speed diesel engines are operated by two methods; one is the electric motors, and the other air starting motors. Even though air starting motor is dependent of the engine types and sizes, it has been widely used in this area due to its simplicity, convenience and reliability. However most of them are currently imported from overseas due to the lack of the cutting-edge technology in terms of design and manufacturing. Therefore, from the point of this view, the air starting motor needs to be produced by our own techniques. The purpose of this paper is to give the designing parameters in order to make a proper "Air Starting Motor" using CFD. The aerodynamic approaches were given to understand the internal flow characteristics of the air starting motor. In addition, we have carried out the effects of tip clearance. In the calculations the tip clearance of air starting motor has been varied between 0% and 5.7% of blade span.

Characteristics Analysis for Reactor Starting Method of 3-Phase Induction Motor Considering Saturation (포화성분을 고려한 3상 유도전동기 리액터 기동 특성 분석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.65-70
    • /
    • 2012
  • Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor generates a high current at startup. Most of starting currents are often more than five times of rated current. This high starting current can cause problems such as the voltage drop in the system. In order to solve these problems, if the motor capacity is large, generally we use reactor starting method rather than direct on line starting method. When a high startup current passes through reactor, reactor can serve as a nonlinear elements. In this study, we analyzed that the current, torque and power of the induction motor are different from the change of linear and nonlinear components of the reactor magnetic field.

A Characteristic Study on the Power Factor Compensation Application of High Voltage Induction Motor (고압 유도전동기 역률 보상설비의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.225-230
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Reactive power doesn't contribute to work but needs to sustain the electromagnetic field required for the induction motor to operate. Starting power factor of induction motor is specially lower than running power factor. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is occasionally being hit by the effects of the starting reactor connection position at the starting, stopping of high-voltage induction motor. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

Position Sensorless Starting of BLDC Motor for Compressor (압축기용 BLDC 전동기의 센서리스 기동)

  • Lee, Kwang-Woon;Lee, Joon-Hwan;Choi, Jae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.440-446
    • /
    • 2006
  • The magnitude of output torque in a BLDC Motor depends on torque angle so that the exact initial position of rotor is essentially required for good starting. This paper presents a novel starting control method for smooth starting in a position-sensorless controlled BLDC motor drive for reciprocating compressor of refrigerator. The proposed method starts a BLDC motor using information on the initial position of rotor, determined from current response characteristics, and shows robust starting capability to starting load variations. The effectiveness of the proposed method is verified through experimental results.

A Study on Starting Characteristic and Improvement for High Power Motor with Tunnel Boring Machine (TBM용 대용량 전동기의 기동 특성 및 개선 관한 연구)

  • Kim, Tae-Kue;An, Joon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.44-51
    • /
    • 2019
  • Tunnel Boring Machine's Technology has depends mostly on imports, currently domestic technology development was proceeding. There are many technologies in this field, above all, the large-capacity motor drive technology required for excavation is one of the core technologies. In particular, when several large motors are simultaneously starting, there are many problems due to a large starting current at that time, and it is difficult to design and operate a power receiving facility. In this paper, A method of reducing the starting current by using the regenerative power generated by the deceleration of the motor has been studied. To verify this proposal, we designed the induction motor controller using CAE based power simulation tool and verified the results of the proposed method by applying the reduced model. As a result, it is possible to reduce the maximum starting current and shorten the start-up time. Moreover, even if several motors are connected to one bank, it is proved that the method can be efficiently operated by using the sequential braking / starting sequence. In the case of a power system in which a large capacity electric motor such as a tunnel excavation system is driven, the results of this study are expected to be a stable and effective method for solving the start-up current problem and designing the power receiving facility.

Analysis of Soft Start-up Characteristics of the Induction Motor Considering the Firing Angle (점호각을 고려한 유도전동기의 소프트 기동 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1007-1012
    • /
    • 2016
  • Induction motors are used widely in driving load of a fluid, such as a pump or a fan in the industry. Induction motor has been generated the voltage drop by the occurrence of a high current during startup. In addition, high start-up current can act as a mechanical stress on the shaft of the motor. So there is need a way to reduce the starting current. Soft start method is one of the many ways to reduce the starting current. This method uses silicon-controlled rectifiers(SCRs) for varying value of the voltage applied to the motor. There is a case for fixing or changing the thyristor firing angle to adjust the magnitude of the voltage. Starting power factor of induction motor is very low compared to the normal operation. Soft starting with the firing angle fixed needs to be considered a low power factor at startup. In this study, we compared the direct start characteristics and soft start characteristics considering the low power factor at the time of start-up. It was possible to confirm that the starting current and the voltage drop is present differently according to the firing angle.