• Title/Summary/Keyword: Motor circuit

Search Result 1,188, Processing Time 0.028 seconds

Analysis of Squirrel Cage Induction Motors with Stator Winding Inter-turn Short Circuit (고정자 권선 단락에 따른 농형 유도전동기의 특성해석)

  • Kim, Mi-Jung;Kim, Byong-Kuk;Moon, Ji-Woo;Cho, Yun-Hyun;Hwang, Don-Ha;Kang, Dong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.150-152
    • /
    • 2007
  • The stator faults yield asymmetrical operation of induction machines, such as irregular current, torque pulsation, increased losses and decreased average torque. So it is necessary to detect the stator faults and develope the monitoring system for detecting faults including vibration and noise. This paper describes the method to analysis the induction motors with the stator winding inter-turn short for investigation of the asymmetrical operation during normal and transient states. And a simple method is used for the simulation and analysis of the induction machines with stator asymmetries. Finally, simulation results, finite element analysis and experimental ones are presented. The results can be useful for real-time on-line monitoring of an induction motor.

  • PDF

A Operating by the Direct Thrust Control of SLIM in Conveyor System (반송용 SLIM의 추력제에에 의한 운전특성)

  • 우정인;노태균;신동률;노인배
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.59-66
    • /
    • 1998
  • In this paper, the thrust control of PWM Inverter-Fed SLIM(Single-sided Linear Induction Motor) is achieved with Space Vector control and PI control. The trembling of air gap length which is occurred between the primary winding core and the secondary structure of the SLIM must be minimized in order to get quick response characteristics. First, the equivalent circuits and voltage equations of SLIM are shown on th suitable d-q axis which analyze characteristics of the thrust and the normal force. Also, modeling and analysis of the equivalent circuits transferred d-q axis are able to make robust transient torque from the current regulation in the equivalent circuit. These results exemplified the direct drive of SLIM with the reference speed and torque were verified by experiments.

  • PDF

Dynamic Analysis on the Energy Regenerative Brake of Hydraulic Driven Systems (유압 구동계 에너지 제생 브레이크의 동특성 해석)

  • 이재구
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.4
    • /
    • pp.137-146
    • /
    • 2000
  • The hydraulic energy regnerative brake systems is introduced in this work. An accumulator stores kinetic energy during braking action, and the stored energy is used in a following acceleration action. The dynamic model of the brake system is derived for computer simulation study, and the Runge-Kutta numerical integration method is applied to the simulation work. Since the model contains several unknown parameters, these were determined by data which had been proceeded. Through a series of computer simulation , dynamic performance of the energy regenerative brake system is compared with that of a conventional system in which a conventional brake circuit is used. A series of test is carried out in the laboratory. The dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, are investigated in both brake action and acceleration action.

  • PDF

Conceptual Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine (풍력터빈 성능시험을 위한 저속풍동 개념연구)

  • Kang, Seung-Hee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.4
    • /
    • pp.24-29
    • /
    • 2011
  • Conceptual study of an open-circuit type low-speed wind tunnel for performance test of wind turbine blade and airfoil is conducted. The tunnel is constituted of a settling chamber, a contraction, closed test section, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The contraction ratio is 9 to 1 and maximum speed in the test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine and airfoil.

An Improved Method of Faulted Section Identification Algorithm in Distribution Automation System (배전자동화시스템에서 단말장치의 고장표시 정보 생성 알고리즘 개선 방법)

  • Lim, Il-Hyung;Lim, Seong-Il;Lee, Seung-Jae;Kwon, Sung-Chul;Shin, Chang-Hoon;Ha, Bok-Nam;Choi, Myeon-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.651-659
    • /
    • 2007
  • This paper proposes an improved fault indication algorithm in a distribution automation system. A conventional fault indication method, so called YES-NO algorithm, could generate wrong informations under certain conditions such as line to ground fault, large motor double circuit line. In order to prevent mal-operation of fault indicator, direction of fault current are used as well as magnitude. The feasibility of the proposed algorithm has been testified by computer simulation using Matlab power system toolbox.

A Study on Electrical Fire of Small Ventilators due to Aged Degradation (경년열화에 의한 소형 환풍기의 전기화재에 관한 연구)

  • Lim, Jong Yong;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.22-26
    • /
    • 2016
  • "Always-on" small ventilators are likely to experience thermal decomposition of insulating material due to thermal, electrical, mechanical and environmental influences, and lose insulating properties by the process of oxidation and physiochemical reaction. This increases the risk of electrical fire because of layer short, short circuit, overload and Plastics are usually used to make ventilator and ventilator enclosures since they make less noise and are cheaper. Although more preferred than iron, plastic, a combustible material, has a higher risk of fire. In this study, several experiments were carried out to find out how RCD(Residual Current Protective Device) and Thermal fuses, which are electric motor protection devices, work and what needs to be done to reduce the risk of fire.

Mathematical Models for the Analysis of a SRM (SRM 해석의 수학적 모델)

  • Kim Bong-Chul;Chen Hao;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.997-1000
    • /
    • 2004
  • The mathematical models of the Switched Reluctance machine system integrating the state equation of the phase current with the two dimensions finite element model of the machine are advanced, no matter what the topologies of the main circuit of the power converter and the control strategies are adopted in the system. Based on the mathematical models, the comparison of the simulated and the tested results of a three-phase Switched Reluctance motor drive prototype system are given. The simulated results of the prototype tally with the tested results of the prototype. It is shown that the mathematical models have the advantage in high precision.

  • PDF

A Low Cost Switched Reluctance Motor Position Sensing Method Using Reflective Type Photo-sensors (반사형 광센서를 이용한 저가형 SRM 위치검출기법)

  • Kim S. J.;Yoon Y. H.;Jung G. H.;Won C. Y.;Kim Y. R.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.219-223
    • /
    • 2004
  • Since rotor position information is necessary to drive the SRM, absolute-encoder, resolver and incremental encoder is used to detect a rotor position. But, it is not desirable to use a high price encoder and microprocessor under the condition of the simple driving system when precision control is not demanded. In this paper, only using the reflective type two photo-sensors replaces the conventional opto-interrupter and slotted-disk, which not only remove a slotted-disk section but drive three-phase 6/4 pole SRM bidirectionally, Therefore, control circuit can compose common analog device with low price.

  • PDF

An On-line Rotor Resistance Estimator for Induction Machine Drives

  • Kwon, Chun-Ki
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.354-364
    • /
    • 2009
  • Rotor resistance variation due to changing rotor temperature is a significant issue in the design of induction motor controls. In this work, a new on-line rotor resistance estimator is proposed based on an alternate qd induction machine model which provides better mathematical representation of an induction machine than the classical qd model (which uses constant parameters). This is because the former simultaneously includes leakage saturation, magnetizing path saturation, and distributed circuit effects in the rotor conductors. The comparisons via computer simulation studies show the ability of the proposed estimator to accurately track rotor resistance variation. For the experimental studies, due to the difficulty in measuring the actual rotor resistance, comparison of the controller performance using the proposed estimator, the classical qd model based estimator, and no estimator is made.

Internet Based Remote Control and Monitoring for Motor (인터넷기반 모터 원격제어 및 모니터링)

  • Kang, Shin-Young;Kim, Eun-Ju;Wi, Seog-Oh;Kim, Gwang-Heon;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.279-285
    • /
    • 2002
  • This Paper deals with the economical equipment control which is used by internet network system at the industrial workplace. If the control devices can be accessed by internet, we can have the developed possibility of work conditions. in this paper, we presented the advanced digital timer which has a communication function to control and observe panel to realize control solution based on internet to be easily applicable at workplace with low cost, and we used RS-485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet. As the result for experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.