• 제목/요약/키워드: Motor block

검색결과 264건 처리시간 0.019초

우측 경련성 사경 수술적 치료 후 좌측에 발병한 경련성 사경 환자에서 시행된 국소마취제 신경차단술의 임상효과 - 증례보고 - (Positive Effects of Local Anesthetic Nerve Blocks for a Patient with Newly Developed Left Side Spasmodic Torticollis after Surgical Intervention of Right Side Spasmodic Torticollis - A case report -)

  • 최창훈;최진환;성춘호
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.246-250
    • /
    • 2007
  • We report here on a case of right side spasmodic torticollis (ST) that was refractory to botulinum toxin type A injection and medication. The patient finally underwent a selective ramisectomy with ipsilateral sternocleidomastoid muscle (SCM) resection, but the remaining symptoms slowly aggravated, and a contralateral left side SCM spasm began. As conservative therapy for reducing the spasmodic symptoms, accessory nerve block, upper cervical plexus block and stellate ganglion block were performed twice in a week. After 6 months, the spasmodic symptoms significantly decreased. The Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS) decreased by more than 70%. After one year of serial intermittent local anesthetic blockade therapy, the patient became almost free from the original ST symptoms (TWSTRS = 1). Serial local anesthetic interventions for the ST patient may have a beneficial role on the pathological peripherocentral neural activity of the ST patient and can modulate motor-sensory integration in the patient.

경막외 페놀 신경 차단시 우연히 발생한 경막하 카테터 거치예 (Accidental Subdural Catheterization for Epidural Neurolysis with Phenol -A case report-)

  • 임경임;김석홍
    • The Korean Journal of Pain
    • /
    • 제11권1호
    • /
    • pp.155-159
    • /
    • 1998
  • Epidural neurolysis with phenol has appeared in literature since 1960. Complications due to accidental subdural block is a rare and unexpected sensory and/or motor disturbance, but it does occur. A 74 years old woman had postherpectic neuralgia for 3 weeks and VAS score of 10. She was treated with intercostal nerve block and intravenous infusion of lidocaine for 7 days and VAS score decreased to 6. To proceed further, we decided to perform epidural neurolysis with 4% phenol 1.5 ml. During thoracic epidural catherization, we encountered unexpected subdural catheterization in subdurographic finding, but we could not precisely rule out subdural catheterization. We had to check CT for exact location of catheter tip. We then performed subdural neurolysis with phenol. This procedure reduced VAS score to between 3 and 4, and we removed the catheter. She had no complication.

  • PDF

Acute Cervical Subdural Hematoma with Quadriparesis after Cervical Transforaminal Epidural Block

  • Lee, Jun Kyu;Chae, Ki Whan;Ju, Chang Il;Kim, Byoung Wook
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권5호
    • /
    • pp.483-486
    • /
    • 2015
  • Cervical epidural steroid injection is frequently used in the conservative management of neck pain and cervical radiculopathy. Epidural cervical transforaminal injections are usually well-tolerated with mild side effects such as transient decreased sensory and motor function, or headache due to dural puncture. Although there are a few case reports about adverse effects of cervical epidural injection in the literature, it can cause severe complications such as large hematoma, infarction by spinal vascular injury. Subdural hematoma has been occurred much less common rather than epidural hematoma in the spinal cord. We report a rare catastrophic case of cervical spinal subdural hematoma with quadriparesis after cervical transforaminal epidural block.

상 하복신경총 차단을 이용한 골반내 통증관리 (Superior Hypogastric Plexus Blocks for Malignant Pelvic Pain)

  • 강성희
    • The Korean Journal of Pain
    • /
    • 제5권1호
    • /
    • pp.108-112
    • /
    • 1992
  • Pain from pelvic cancer is very difficult to manage because it's vague ness and bilateral nature. Furthermore, nerve blocks in this area are dangerous because sensory afferent nerves from pelvic viscera are adjacent to nerves that regulate bowel and bladder control, and motor nerve of lower extremities'. Bilateral lumbar sympathectomy has been used for malignant pelvic pain with little risk of neurologic complication. However it is not a specific block for pelvic visceral pain, because the lumbar sympathetic chain does not innervate pelvic viscera in a direct manner. Therefore the potentials of lumbar sympathectomy for pelvic visceral pain are attributed to caudad diffusion of neurolytic agents to the smperior hypogastric plexus. I have experienced 3 cases of superior hypogastric plexus neurolysis per se without any significant complications.

  • PDF

신경차단 시 국소마취제와 함께 사용되는 보조 약물들 (Adjuvant medications to local anesthetics in nerve blockade)

  • 이덕희
    • Journal of Yeungnam Medical Science
    • /
    • 제34권2호
    • /
    • pp.161-168
    • /
    • 2017
  • Peripheral nerve blocks are commonly used for surgical anesthesia, postoperative analgesia, and to reduce opioid requirements. Although these blocks have traditionally been carried out using local anesthetics, single-injection techniques can be short-lived and limited by the relatively brief duration of action of currently available local anesthetics. Increasing the dose or concentration of local anesthetics may prolong the duration of analgesia, but may also increase the risk such as unwanted motor weakness or systemic toxicity of local anesthetics. Numerous adjuvant medications have been added to local anesthetics to prolong the durations of anesthesia and analgesia achieved by peripheral nerve blocks, and currently, a number of different adjuvants are used to improve quality of the block. This article will review the several nerve block adjuvants used in combination with local anesthetics to provide blockade of peripheral nerves in clinical practice, describing the rationale for their use in peripheral nerve blocks, and the evidence for their effectiveness.

비데오 데크 메카니즘의 로딩블럭 해석 및 설계 (Design and Analysis of Loading Block of VCR Deck Mechanism)

  • 박태원;김광배
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.502-511
    • /
    • 1994
  • A video deck mechanism is composed of various cams, links, and gears, and it requires precise movement. So kinematic motion between parts should be considered to get desired movement depending on the timing chart which defines movement of each part to get desired mode. Also dynamic effects should be considered to get right tape tension and to estimate motor force required to obtain accurate motion. The design process of the deck mechanism of VCR is explained briefly. The loading block of the deck mechanism is divided into a tape translational group and a brake control group. Each group is modeled for kinematic and dynamic analysis. Finally, two groups are combined together to analyze the loading block of the deck mechanism. Results are used to understand and modify an existing design.

Exacerbation of spasticity in ipsilateral shoulder after right brachial plexus block in a patient with right hemiplegia

  • Park, Sang-Jin;Baek, Jong-Yoon
    • Journal of Yeungnam Medical Science
    • /
    • 제32권1호
    • /
    • pp.22-25
    • /
    • 2015
  • Spasticity is a common impairment in patients with central nervous system disease. Clinical observation has demonstrated that spasticity can be aggravated by various factors such as emotional state as well as noxious stimuli. A 51-year-old male patient was scheduled for arteriovenous fistula surgery. He had right hemiplegia including motor weakness and spasticity. It was decided that the surgery would be performed under an axillary brachial plexus block (BPB). He appeared nervous when blockade was terminated. The spasticity of the right shoulder increased after ipsilateral BPB. However, when we administered sedative drugs and performed interscalene BPB 2 days later, spasticity did not occur. Exacerbation of spasticity might be evoked by an anxious emotional state. Thus, it seems to be good to consider removing of anxiety and using an appropriate approach when it is tried to perform nerve blocks in individuals with spasticity.

지속적 경막외차단중 발생한 경막외 감염증 (Epidural Infection during Continuous Epidural Block)

  • 사희순;김태헌
    • The Korean Journal of Pain
    • /
    • 제2권1호
    • /
    • pp.97-99
    • /
    • 1989
  • Epidural block is used extensively in each of the fields of surgical anesthesia, obstetric anesthesia, and diagnosis and management of acute and chronic pain. New developments in the understanding of pain conduction have extended the use of continuous epidural blockade to the administration of drugs that selectively block pain conduction while leaving sensation and motor power essentially unchanged. The safety and the reliability of spinal epidural catheter techniques have permitted relief of acute and chronic pain. However, one of the important aspects of the management of the epidural catheter is the possibility of epidural infection. We have experienced a case of epidural infection during control of post-herpetic neuralgia and discuss management of the epidural catheter in this article.

  • PDF

동굴 공간의 안전과 방재차단벽 (Embodiment of Firewall Block for Safety in the Cave)

  • 김보수;김강원;김태환;박정호;이영재;소대화
    • 동굴
    • /
    • 제87호
    • /
    • pp.8-13
    • /
    • 2008
  • The automatic firewall block and fire alarm system was embodied by using gas circuit and wireless communication equipment, using a smoke sensor (ST-QA1A) and RF Module. OR-CAD was also used for testing circuit system and experiment circuit after assembling circuit. As a result in experiment, the gas sensor detected well an imaginary smoke and worked reliably for driving action of firewall block motor and wireless warning alarm. Through the smoke sensitive perception from the fire, the warning alarm and the preventing fire propagation from the specific closed region were verified reliably. The gas sensor and RF module for firewall and fire alarm system were actually available.

MATLAB/SIMULINK의 TI C2000 DSP 임베디드 타겟을 이용한 동기 전동기 구동 시스템 (PMSM Drive System Using Embedded Target for TI C2000 DSP in MATLAB/SIMULINK)

  • 이용석;지준근;차귀수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.400-402
    • /
    • 2007
  • This paper presents a vector control implementation for PMSM using Real Time Workshop and Embedded Target for TI C2000 DSP in MATLAB/SIMULINK. Speed, current and vector controllers are easily designed and implemented by using the MATLAB/SIMULINK program. Feedback of motor speed is processed through C28x QEP(Quadrature Encoder Pulse) block from encoder pulse. 3-Phase currents ares processed through C28x ADC block from current sensors. And gating signal of PWM inverter is generated through SVPWM and PWM block. Real-time program is drawn using SIMULINK and then converted program code for speed control of PMSM is downloaded into the TI eZdsp 2812 board. Experiments were carried out to examine validity of the proposed vector control implementation.

  • PDF