• Title/Summary/Keyword: Motor Vibration Suppression

Search Result 50, Processing Time 0.027 seconds

Motor Vibration Suppression during V/F Operation at Light-Load (V/F 운전시 전동기 경부하 진동 개선)

  • Hong, Sung-Min;Jung, Se-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.375-376
    • /
    • 2014
  • 본 논문은 전동기의 V/F 운전시 발생하는 경부하 진동을 억제하는 방법을 제안한다. 제안한 방법은 기존의 무부하 전류를 사용하는 방법을 변형하여 V/F 운전시 전원 및 기계적 진동에 의해 발생하는 경부하 진동을 억제하여 운전 특성을 향상시킨다. 제안한 방법을 적용한 V/F 운전 특성을 실험을 통하여 검증하고 기존의 V/F 운전 대비 개선된 성능을 비교 분석한다.

  • PDF

Vibration Suppression of Moving Suspended Systems by Wave Absorption Control

  • Saigo, Muneharu;Nam, Dong-Ho
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.6 no.1
    • /
    • pp.30-37
    • /
    • 2003
  • This paper describes vibration control of a suspended system using wave absorption method. A moving multiple-pendulum system and a moving wire-and-load system are treated. The wire-and-load system is extended to a model crane system that has a motor system to roll up and down the suspended mass like a real crane. The same program with different parameter values controls these three systems. Both numerical simulation and experiment have been conducted, and the present control method has shown to be quite effective.

  • PDF

A Feedback Control System for Suppressing Crane Oscillations with On-Off Motors

  • Hekman, Keith A.;Singhose, William E.
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.3
    • /
    • pp.223-233
    • /
    • 2007
  • Crane payloads frequently swing with large amplitude motion that degrades safety and throughput. Open-loop methods have addressed this problem, but are not effective for disturbances. Closed-loop methods have also been used, but generally require the speed of the driving motors to be precisely controlled. This paper develops a feedback control method for controlling motors to cancel the measured payload oscillations by intelligently timing the ensuing on and off motor commands. The effectiveness of the oscillation suppression scheme is experimentally verified on an industrial bridge crane.

Active Vibration Control of a Plate Using TMS320C6713DSK

  • Choi, Hyeung-Sik;You, Sam-Sang;Her, Jae-Gwan;Seo, Hae-Yong;Tran, Ngoc-Huy
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.309-316
    • /
    • 2011
  • This paper deals with the experimental study of the vibration suppression of the smart structures. First, a new high-speed active control system is presented using the DSP320C6713 microprocessor. A peripheral system developed is composed of a data acquisition system, A/D and D/A converters, piezoelectric (PZT) actuator/sensors, and drivers using PA 95 for fast data processing. Next, the processing time of the peripheral device is tested and the corresponding test results are provided. Since fast data processing is very important in the active vibration control of the structures, achieving the fast loop times of the control system is focused. The control algorithm using PPF in addition to FIR filter is implemented. Finally, numerous experiments were carried out on the aluminum plate to validate the superior performance of the vibration control system at different control loop times.

Fuzzy -Logic Controller for Flexible-Link Manipulators (유연 링크 로봇의 제어)

  • 강재용;박종현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.342-345
    • /
    • 1995
  • This paper describes the design process and the experimental results of a fuzzy logic controller to control the tip position of a fixible-link manipulator, directly driven by a AC motor, with a large payload. The joint angle fuzzy logic controller is designed without a costly nonlinear system analysis of the flexible manipulator and the AC motor drive system. The state variables for the fuzzy logic controller are joint angle, joint velocity, link deflection, and link deflection velocity. The simulation and experimental results show that the joint position control is not satisfactory when the controller is designed under the assumption of no link flexibility and that stable joint position control and link vibration suppression can be cahieved with the fuzzy logic controller suggested in this paper.

  • PDF

The Improvement of Position Precision for Hybrid Linear Pulse Motor

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.28-33
    • /
    • 2001
  • The subject of this study is to improve the position performance of the linear motion for hybrid type Linear Pulse Motor (HLPM). Generally, there are two applicable methods to ensure precise position control ; a good processing method. This paper is suggested an electrical 125 microstep driving method so as to achieves the excellent control performance, besides the small mechanical manufacture of teeth pitch. The compensation method of digital PI control is apply to step response of stable position control, step error, vibration suppression and the approach to high stability, and the Ziegler-Nichols tuning method is applied to the proper design of control parameter. The proposed control method has been verified by simulation results of the suitable gain and phase margin of bode plot, and from experiment result of step response.

Active Control of Isolation Table Using $H_\infty$ Control ($H_\infty$ 제어를 이용한 방진대의 능동제어)

  • Kim, Kyu-Young;Yang, Hyun-seok;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3079-3094
    • /
    • 1996
  • Recently, the high-precision vibration attenuation technology becomes the essence fo the seccessful development of high-integrated and ultra-precision industries, and is expected to continue playing a key role in the enhancement of manufacturing technology. Vibration isolation system using an air-spring is widely employed owing to its excellent isolation characteristics in a wide frequency range. It has, however, some drawbacks such as low-stiffness and low-damping features and can be easily excited by exogenous disturbances, and then vibration of table is remained for a long time. Consequently, the need for active vibration control for an air-spring vibration isolation system becomes inevitable. Furthermore, for an air-spring isolation table to be successfully employed in a variety of manufacturing sites, it should have a guaranteed robust performance not only to exogenous disturbances but also to uncertainties due to various equipments which might be put on the table. In this study, an active vibration suppression control system using H.inf. theory is designed and experiments are performed to verify its robust performance. An air-spring vibration isolation table with voice-coil-motors as its actuators is designed and built. The table is modeled as 3 degree-of-freedom system. An active control system is designed based on $H_\infty$control theory using frequency-shaped weighting functions. Analysis on its performance and frequency responce properties are done through numerical simulations. Robust characteristics of$H_\infty$ control on disturbances and model uncertainties are experimentally verified through (i) the transient response to the impact excitation of the table, (ii) the steady-state response to the harmonic excitation, and (iii) the response to the mass change of the table itself. An LQG controller is also designed and its performance is compared with the $H_\infty$ controller.

Dynamic analysis and controller design for a slider-crank mechanism with piezoelectric actuators

  • Akbari, Samin;Fallahi, Fatemeh;Pirbodaghi, Tohid
    • Journal of Computational Design and Engineering
    • /
    • v.3 no.4
    • /
    • pp.312-321
    • /
    • 2016
  • Dynamic behaviour of a slider-crank mechanism associated with a smart flexible connecting rod is investigated. Effect of various mechanisms' parameters including crank length, flexibility of the connecting rod and the slider's mass on the dynamic behaviour is studied. Two control schemes are proposed for elastodynamic vibration suppression of the flexible connecting rod and also obtaining a constant angular velocity for the crank. The first scheme is based on feedback linearization approach and the second one is based on a sliding mode controller. The input signals are applied by an electric motor located at the crank ground joint, and two layers of piezoelectric film bonded to the top and bottom surfaces of the connecting rod. Both of the controllers successfully suppress the vibrations of the elastic linkage.

A Study on the Improvement of Misfire Detection Method with Vibration by using the Weight Factor (후진동이 나타나는 실화 진단 방법에서 가중치를 이용한 성능 향상에 대한 연구)

  • Lim Jihoon;Lee Taeyeon;Kim Ealgoo;Hong Sungrul;Sung Jinho;Park Jaehong;Yoon Hyungjin;Park Jinseo;Kim Dongsun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.74-80
    • /
    • 2005
  • This paper presents a misfire monitoring method by using the weight factor. According to OBD II(On-Board Diagnostics) regulations of the CARB (California Air Resources Board), an ECU (Electronic Control Unit) should detect misfires which occur in the internal combustion engine. A misfire is 1311owe4 by post-oscillations for short duration. Sometimes, the amplitude of oscillations may be as high as misfire and can be falsely detected as another misfire. To prevent this, the software designers do not attempt to detect another misfire for this short duration, during which the post oscillations exist. Because of this, ECU does not detect all the misfires and hence, the unstable state of automobile cannot be detected. If this happens for a long time, automobile may get damaged. To solve these problems, this paper suggests a new algorithm to detect misfire by using weighting factor Weighting factor is a concept to distinguish the misfire with the post oscillation and to improve the detection rate. This value of weighting factor is used for counting the misfire. This paper also shows the result of experiment done on a automobile using this software. The software is implemented using ASCET-SD which is preferred in the design of engine control. This paper's result show the possibility of improving the misfire detection by implementing this algorithm.

Pulsatile Pressure Distribution on the Snubber of Reciprocating Compressor (왕복동식 압축기의 스너버내 맥동압 분포)

  • Lee, Gyeong-Hwan;Rahman, Mohammad-Shiddiqur;Chung, Han-Shik;Jung, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.606-611
    • /
    • 2007
  • Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. This study discusses pressure pulsation phenomena occurred in a reciprocating compressor system. An experiment applied air compressor unit, as pulsating pressure generator, has been done. The compressor was connected sequentially to a snubber model and pressure tank. Sensor probes were placed on the inlet and outlet pipes of snubber. Compressor was driven by a motor controlled by a frequency regulator. The experiment was conducted by adjusting the regulator at 40Hz. General information about an internal gas flow can be achieved by numerical analysis approach. Information of the velocity, pressure and turbulence kinetic energy distribution are presented in this paper. Based on this result, the design improvement might be done.

  • PDF