• 제목/요약/키워드: Motor Pump

Search Result 453, Processing Time 0.029 seconds

Electric Water pump Development (전동식 워터펌프 개발)

  • Jung, Se-Young;Kwak, Joong-Hee;Park, Bum-Yong;Jung, Woo-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.217-220
    • /
    • 2007
  • The purpose of study is a development of the high reliance electric driven water-pump that fuction is forcing the movement of water using basic design, proto sample and test at the cooling system. It was important to supply a coolant quickly and accurately for the requirement of flow rate at the system when we carried out the designs for BLDC Motor, Controller and water pump(Impeller, Volute Casing, Sealing Device) First, we attained ours purpose that the target efficiency for water pump was over 40% and then we are doing the optimum design for Brushless Motor and Controller that its target is over 55% of efficiency.

  • PDF

Reducing the Axial Thrust of the Submersible Motor Pump (수중모우터펌프의 축추력 저감에 관한 연구)

  • 정명진;갈원모;이영자
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.42-46
    • /
    • 1992
  • The submersible motor pump could have much more merits than the general pump such as higher exhaustion head, narrower installahon place, lower noise due to operating in the water and so on. But, so far, hydraulic mechanism of the axial thrust at impeller was not analysed quantitatively and so it is very difficult to solve the occuring problems. Therefore, in this study, we aimed to minimize the axial thrust acting on thrust bearing of submersible motor pump through the analysis of hydraulic mechanism of thrust and design rivision of impeller. Test carried out on the pump with an impeller 92mm in diameter, 6 balacing holes 10mm in diameter, showed the thrust is reduced by about 86% at the normal operating point.

  • PDF

Design and Analysis of Electromagnetic Pump Using Linear Induction Motor (선형유도전동기를 이용한 전자기펌프의 설계 및 해석)

  • Kim, Chang-Eob;Jeon, Mun-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.68-73
    • /
    • 2005
  • This paper presents the characteristics analysis of an electromagnetic pump using the linear induction motor(LIM). The electromagnetic pump can be used to transfer the molten metals by the electromagnetic force of LIM. The characteristics of the pump are analyzed solving a hydrodynamic equation with an electromagnetic one.

Diagnosis of Cryogenic Pump-Motor Systems Using Vibration and Current Signature Analysis

  • Choi Byeong-Keun;Kim Hak-Eun;Gu Dong-Sik;Kim Hyo-Jung;Jeong Han-Eul
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.972-980
    • /
    • 2006
  • In general, to send out natural gas via a pipeline network across the nation in LNG terminal, high-pressure cryogenic pump supply highly compressed LNG to high-pressure vaporization facilities. The Number of cryogenic pumps determined the send-out amount in LNG receiving terminal. So it is main equipment at LNG production process and should be maintained on best conditions. In this paper, to find out the cause of high vibration at cryogenic pumps-motor system in LNG terminal, vibration spectrum analysis and motor current signature analysis have been performed together. Through the analysis, motor rotor bar problems are estimated by the vibration analysis and confirmed by the current analysis. So, it is demonstrated through the case study in this paper, how performing vibration analysis and current signature analysis together can reliable diagnosis rotor bar problems in pump-motor system.

Reed Resonance Problems of Large Vertical Pumps (대형 수직펌프의 리드공진 문제)

  • 최원호;양보석
    • Journal of KSNVE
    • /
    • v.4 no.4
    • /
    • pp.425-433
    • /
    • 1994
  • A detailed investigation of a reed resonance for a vertical pump design has been conducted. The structural features of this class of pump lead to typical dynamic characteristics. Of particular importance is the fact that the pump assembly is suspended on a high column above the floor with a heavy motor on the top. Considerable amount of mass forces is involved and the vibration can cause damage to the pumps or to the foundation. It is shown that the reed resonance of the pump-motor system plays important role for design and troubleshooting purposes.

  • PDF

Study on the Generating Operations of the Induction Motor for Driving the Pump During Instantaneous Power Interruption (순간 정전시 펌프 구동용 유도전동기의 발전 동작에 관한 연구)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.65-70
    • /
    • 2016
  • Power interruption is a phenomenon that no voltage is displayed over a short time or long time. Most devices will not operate normally when the supply voltage is low or does not exist. However, the device can also be operated with a different power which is ensured by a separate power generation. Recently, power interruption has been reduced gradually by the improvement of electricity quality, its duration also has been very short. Induction motors are widely used for the pumping in the water and sewage facilities and power plant applications. The pump is used as a machine for moving the fluid in the high place from a low location. So pump equipment always have a potential energy. If a momentary interruption occurs, the potential energy of the pump is reversed as that of water turbine and motor is operated as generator. This study is an analysis for the voltage variation, current, torque and power flow by the generating operation of the induction motor before and after the change of momentary interruption.

An Analysis on Volumetric Displacement of Hydraulic Gerotor Pump/Motor using Energy and Torque Equilibrium - First Report: Case of Rotation of Inner and outer Rotors - (에너지보존과 토크평형을 이용한 제로터 유압 펌프/모터의 배제용적 해석 - 내·외부로터 회전 경우 -)

  • Kim, S.D.;Kim, D.M.;Ham, Y.B.
    • Journal of Drive and Control
    • /
    • v.10 no.2
    • /
    • pp.13-22
    • /
    • 2013
  • It is difficult to analytically derive a volumetric displacement formula of gerotor hydraulic pump/motor because geometric shape of rotors is complicated. An analytical method about the volumetric displacement is proposed in this work, which is relatively easy and based upon two physical concepts. The first one is energy conservation between hydraulic energy of the pump/motor and mechanical input/output energy. The second concept is torque equilibrium with respect to inner and outer rotors. The formula about the volumetric displacement is derived for the common case of inner and outer rotors rotate with respect to fixed axes. The formula is verified by comparing another analytical displacement formula, and it is numerically verified by comparing numerical results, which is calculated for geometric specification of a motor. The numerical displacement is calculated through CAD software program and MATLAB program. The proposed analytical formula can be utilized in analysis and design of hydraulic gerotor motors.

Size and Shape Optimization of the Oil Pump for Fuel Consuming Reduction (엔진 연비 향상을 위한 오일펌프 사이즈/형상 최적화)

  • Jo, Sok-Hyun;Nam, Kyung-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.22-28
    • /
    • 2008
  • Generally block imbedded type oil pump is adopted to make a small engine. In this paper 1D/3D numerical simulations were conducted to reduce energy consumption of the block imbedded type oil pump. At each stage of engine development we have estimated the oil flow rate and pressure to optimize oil pump sizes by using the 1D system analysis and then accomplished 3D CFD(Computational Fluid Dynamics) simulations to optimize oil pump shapes including inlet/outlet port. As a result, the energy consumption of oil pump has been reduced to nearly 27% and the engine fuel consumption to $1{\sim}1.5%$.

Resonance avoidance and Safety Evaluation of Vertical Pump (입형펌프의 공진회피와 안전성 평가)

  • Jeong, Wooyoung;Song, Jindae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.698-702
    • /
    • 2013
  • This paper considers the vertical pumps resonance and soundness. Normally large vertical pump's rotating speed is low, so the low natural mode can make a resonance on the motor and motor stand assembly. The pump resonance makes a very high vibration and trouble on the pump systems. Thus to avoid pump resonance when the pump is on the resonance region, we give the added mass method and evaluate the structure soundness by computer simulation and test on the site. Furthermore we evaluate the modal sensitivity and expect running conditions by the using ISO10814.

  • PDF

Direct Instantaneous Torque Control of Hydraulic Oil Pump System (유압펌프시스템의 직접 순시 토오크 제어)

  • Liang, Jianing;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.150-151
    • /
    • 2007
  • In hydraulic oil pump system, pressure has a linear relationship with output torque of motor. Torque control of pump drive can easily output stable pressure, and it can retain required pressure at minimum speed to save power consumption. Switched reluctance motor(SRM) has many advantages such as low cost and low inertia. It can generate high torque at low speed. But inherent high torque ripple of SRM influences performance of pressure control in hydraulic oil system. This paper presents direct instantaneous torque control(DITC) of hydraulic oil pump system. DITC method can reduce inherent torque ripple of SRM, and output smoothing torque to load. So the proposed hydraulic oil pump system can support smooth pressure and fast dynamic power supply to the hydraulic pump system. At last the proposed hydraulic oil pump system is verified by computer simulation and experimental results.

  • PDF