• 제목/요약/키워드: Motor Pump

검색결과 453건 처리시간 0.02초

소형 수직형 축류 펌프를 위한 축방향 자기 부상 모터 (An Axial-type Self-bearing Motor for Small Vertical Axial-flow Pump)

  • 김승종
    • 한국소음진동공학회논문집
    • /
    • 제11권6호
    • /
    • pp.223-232
    • /
    • 2001
  • Aiming at a small axial pump with a levitated rotor, an axial-type self-bearing motor is presented, which has a rotor wish four permanent magnets and two stators with two-pole three-phase windings. In this system, only the axial motion of rotor is actively controlled by two opposite self-bearing motors just like in the case of an axial magnetic bearing, while the other motions are passively stable. For rotation, It follows the theory of a four-pole three-phase synchronous motor. This paper Introduces schemes for design and control of the self-bearing motor and shows some experimental results to Prove the feasibility of application for the axial Pump.

  • PDF

항공기용 연료승압펌프 설계 (Design and Analysis of the Fuel Boost Pump for the Aircraft)

  • 이정훈;김준태
    • 항공우주시스템공학회지
    • /
    • 제6권4호
    • /
    • pp.18-23
    • /
    • 2012
  • The fuel boost pump for the aircraft was first indigenously developed in Korea. It is one of the core component for fuel subsystem and composed of motor assembly, impeller assembly, and body assembly with BLDC motor. It shall provide some amount of fuel to engine system continuously for any flight condition considering sudden altitude change and any attitude. This paper describes the procedures and the results for the design, the integration, and the performance analysis of the fuel boost pump.

일체형원자로 주냉각재펌프의 검증시험 (Qualification Test of Main Coolant Pump for an Integral Type Reactor)

  • 박상진;윤의수;허필우;김덕종;오형우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.509-514
    • /
    • 2005
  • Main coolant pump (MCP) is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel rods and steam generators in an integral type reactor. The reactor is designed to operate under condition of 310 oC and 14.7 MPa. Thus MCP has to be tested under same operating condition as reactor design condition in order to verify its performance and safety. In present work, a test loop to simulate real operating situation of the reactor has been designed and constructed to test MCP. And then, as a part of qualification test, canned motor functional test and pump hydraulic performance test have been carried out upon a prototype MCP. Canned motor efficiency and pump hydraulic characteristics including homologous curves and NPSH curves were obtained from the qualification test.

  • PDF

원유펌프시스템의 열전달해석 및 냉각설계 (Heat Transfer Analysis and Cooling Design for Crude Oil Pump System)

  • 김완기;이준엽;권중록;김해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2017-2022
    • /
    • 2008
  • The crude oil pump system is the equipment for transporting crude oil and it consists of 3 major components, a motor and an impeller which discharge underground crude oil, a pipestack that transmits the cooling oil and power, and a cooling oil unit & junction box that provides cooling oil and electric power. When considering the system characteristics that it has to be installed at a depth of deeper than 100 m, a design technology for the efficient control of the heat occurring at a conductor and motor is necessary and it is the essential factor for ensuring system durability. In this paper, therefore, cooling oil flow has been calculated to satisfy the limit value of the system temperature by analyzing heat flow considering the related losses such as loss of conductor, contact resistor loss at the conductor connection, and operation loss of motor. And the operation temperature has been set up based on the temperature of crude oil and the heat of motor and conductor. Also, a design for cooling of crude oil pump system has been proposed by calculating the operation pressure loss and selecting the capacity of a cooling oil pump and a heat exchanger.

  • PDF

펌프용 소형 BLDC 모터의 원가절감을 고려한 회전자 최적화 설계 (Optimized Design of Rotor Considering Cost-Reduction of Small BLDC Motor for the Water Pump)

  • 김회천;정태욱
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.495-501
    • /
    • 2013
  • In the present study, a BLDC motor for a pump in which a neodymium PM is replaced with a Ferrite PM has been developed in preparation for the cost increase and to ensure the stability of the resource supply. One of the currently used motors for pumps is a BLDC motor having an interior PM wherein a rare-earth PM is adopted. However, a BLDC motor for a pump is designed to have large airgap because of the use of a waterproof insulator according to its structural characteristics, and therefore, a SPM structure is suitable. Hence, an SPM BLDC motor in which a Ferrite PM is used is designed. Nevertheless, the use of Ferrite instead of rare-earth materials causes a deterioration in the performance of the electric motor, such as a decrease in the BEMF and the maximum power of the motor and the irreversible demagnetization of the PM. In order to mitigate such disadvantages, an optimized design of the BLDC motor is developed by changing each design parameter and by improving the electromagnetism structure.

점도보정을 고려한 펌프선정 프로그램 개발 (Development of Pump Selection Computer Program with Pump Performance Viscosity Correction Function)

  • 김진권;전상규
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.189-192
    • /
    • 2004
  • Utilizing pump selection softwares is becoming a new general trend in pump industries, substituting the old fashioned pump catalogs. One of the most powerful pump selection softwares is developed, which features pump performance viscosity correction function as well as pump selection based on the exact pump performance curves, NPSH warning, automatic determination of impeller diameter cutting to meet the customer's performance specification, performance simulation for the rpm and diameter variation, standard motor recommendation according to the motor standards and enclosure types and automatic pump datasheet generation for sales submission, automatic pump drawings and dimension generation for installation check and part preparation. This software provides pump distributors and customers with a quick, easy and exact pump selection, various performance curves review (system curves, performance curve of series or parallel operation) of the selected pumps.

  • PDF

Development of the Rolling-cylinder Type Motor-driven Total Artificial Heart System

  • Min, Byoung-G.;Kim, Hee-C.;Cheon, Gill-J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.161-170
    • /
    • 1987
  • A new type of motor-driven total artificial heart system with a rolloing-cylinder mechanism has been developed. The prototype system consists of a brushless DC motor inside of a rolling-cylinder, two arc shaped pusher-plate s, and two ventricles of smooth, seamless polyurethane sacs. The motor-driven pump has the advantages of being portable and quiet compared to the present air-driven pump. It can also be controlled more accurately. This rolling-cylinder type electromechanical pump has several structural advantages including small size and weight, as compared to other research groups' motor-driven pumps. The results of mock circulation tests confirm sufficient pump output capacity(cardiac output . 9 L/min, at aortic pressure'120mmHg, with heart rate . 120 BPM) for animal implantation of our prototype system.

  • PDF

모터 펌프를 위한 멀티-모니터링 시스템 설계 및 구현 (Design and Implementation of Multi-monitoring System for Motor Pump)

  • 김태현;양오
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.81-86
    • /
    • 2019
  • According to the needs of many users, motor pumps have been steadily developed and widely used in many industries where fluids are used. Motor pumps are used in a variety of environments, degrading quality and performance. It is becoming important to monitor the condition of motor pumps in order to maintain system performance and increase efficiency. This paper presents the method for effectively monitoring the condition of motor pumps. The designed MMI controller receives the collected data through data logging and output and controls the motor pump with touch screen. Implementing a Wi-Fi monitoring system and SCADA monitoring system based on Ethernet and RS485, user can monitor even if the user is far from the MMI controller without time and space limitation. In addition, by implementing a voice output system, the user can immediately recognize the situation through the sound. Therefore, through the proposed method, multi-monitoring system solves the cause of breakdowns and degradation of motor-pump and gives the possibility of commercialization by providing the convenience of maintenance to users.

항공기용 연료승압펌프 모터 조립체 설계에 대한 연구 (A Study on the Design and Analysis of the Fuel Boost Pump Motor Assembly for an Aircraft)

  • 이정훈;김준태
    • 항공우주시스템공학회지
    • /
    • 제12권3호
    • /
    • pp.1-8
    • /
    • 2018
  • 항공기에서 사용되는 연료펌프를 민군겸용구성품개발사업을 통하여 국내 최초로, 국내 독자기술로 개발하였다. 연료승압펌프의 모터 조립체에 있어서 모터는 효율성, 내구성, 내폭발성 등의 관점에서 DC 브러시 모터보다 특성이 우수한 BLDC 형식을 채택하였다. Maxwell 방정식과 환경조건을 활용하고 자속밀도를 통하여 전자기해석을 수행하였다. 설계를 검증하기 위하여 유한요소법을 이용하여 부하에 따른 모터성능을 해석하였고 모터 드라이브와 EMI 필터를 설계하여 모터 조립체가 개발되었다. 연료승압펌프 모터 조립체의 성능시험 결과는 해석결과와 매우 일치하는 것으로 확인되었다.

SMART 원자로용 냉각재 순환펌프의 온도특성에 관한 연구 (A Study on the Temperature Characteristics of Main Coolant Pump for System-integrated Modular Advanced Reactor)

  • 구대현;방덕제;강도현;김종인;조윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.320-326
    • /
    • 2000
  • The canned motor of 3-phase induction is used for main coolant pump(MCP). The type of motor is canned-motor that stator and rotor are welded by sealed can. So, cooling water flows in the air gap of the canned motor as an independent cycling cooling system from the air gap to yoke of the motor to prevent high temperature of stator can and to lubricate bearing. Heat exchange is occurred between cooling water in the air gap and cooling water from the exterior pump to prevent rising of temperature in the motor. I has to analyze the characteristics of can exactly because the loss and the heat in the can are very important to design MCP. Therefore, thermal analysis is studied considering the effect of eddy-current los induced in the can.

  • PDF