• 제목/요약/키워드: Motor Driven Inverter

검색결과 186건 처리시간 0.034초

가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석 (Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions)

  • 박홍희;박윤철;김용찬
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF

IGBT 인버터 구동 저압 유도전동기의 절연특성 연구 (A Study on the Insulation Characteristics of Low-Voltage Induction Motor driven by IGBT PWM Inverter)

  • 황돈하;박도영;김용주;구자윤;박태익;김진홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.206-210
    • /
    • 1999
  • Since the introduction of IGBT PWM inverters, many low-voltage induction motors have been driven by them. Recently, the stator winding insulation failures have attracted much concern due to high dv/dt of IGBT inverter output. In this paper, presented are the detailed insulation test results of 26 low-voltage induction motors. Six different types of insulation techniques are applied to 26 motors. The tests include PD, $tan{\delta}$, and DIV tests. Also, break-down tests by high voltage pulses are performed.

  • PDF

터보 제너레이터의 시동기 제어에 관한 연구 (A Study on the Starter Control of the Turbo Generator)

  • 박승엽;노민식
    • 제어로봇시스템학회논문지
    • /
    • 제10권3호
    • /
    • pp.286-293
    • /
    • 2004
  • This paper presents the result of a study on the starter control for a turbo generator. Because a starter in gear box type turbo-generator system is composed of gearbox and brush DC motor, it should be replaced with High Speed Generator(HSG)) in HSG type Turbo-generator. There-ore, it is necessary to design a new starting algorithm and starter. In gearbox type system, brush DC motor is rotated to the designed speed using low voltage-high current battery power. After brush DC motor speed is increased to several times by gearbox, gas turbine engine can be rotated to designed starting speed. If we implement a starter with High Speed Generator(HSG), it is necessary to drive high-speed generator to high-speed motor. High-speed generator with permanent magnet on rotor has a low leakage inductance fur driving high-speed rotation, and it is necessary high DC link voltage for inverter when High-speed generator is driven to high speed. This paper presents result of development of the boost converter for converting high voltage DC from low battery voltage and design of the inverter for controlling a high frequency current to be injected to motor winding. Also, we show performance of the designed starter by driving the turbo generator.

Selection of Voltage Vectors in Three-Level Five-Phase Direct Torque Control for Performance Improvement

  • Tatte, Yogesh N.;Aware, Mohan V.
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2162-2172
    • /
    • 2016
  • This paper presents a Direct Torque Control (DTC) strategy for the five-phase induction motor driven by a three-level five-phase inverter in order to improve the performance of the five-phase induction motor. In the proposed DTC technique, only 22 voltage vectors out of 243 available voltage vectors in a three-level five-phase inverter are selected and are divided in 10 sectors each with a width of $36^{\circ}$. The four different DTC combinations (DTC-I, II, III and IV) for a three-level five-phase induction motor drive are investigated for improving the performance of five-phase induction motor. All four of the DTC strategies utilize a combination of the same large and zero voltage vectors, but with different medium voltage vectors. Out of these four techniques, DTC-II gives the best performance when compared to the others. This DTC-II technique is analyzed in detail for improvements in the performance of five-phase induction motor in terms of torque ripple, x-y stator flux and Total Harmonics Distortion (THD) of the stator phase current when compared to its two-level counterparts. To verify the effectiveness of the proposed three-level five-phase DTC control strategy, a DSP based experimental system is build. Simulation and experimental results are provided in order to validate the proposed DTC technique.

Evaluation of Winding Insulation of IGBT PWM Inverter-Fed Low-Voltage Induction Motors

  • Park Doh-Young;Hwang Don-Ha;Kim Yong-Joo;Kang Do-Hyun;Lee Young-Hoon;Kim Dong-Hee;Lee In-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.470-474
    • /
    • 2001
  • IGBT inverters have switching rise times of 0.2-2 $\mu$ sec, and have been believed to cause insulation stresses and premature motor failures. Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted many concerns due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 19 low-voltage induction motors are presented. Different types of insulation techniques are applied to 19 motors. The insulation characteristics are analyzed with partial discharge, discharge inception voltage, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed, and the corresponding breakdown voltages are obtained.

  • PDF

공심슬롯 원통형 선형 BLDC 전동기의 설계 및 특성 고찰 (Design and Characteristics Investigation of Air-core Tubular Linear BLDC Motor)

  • 문지우;조윤현
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.603-609
    • /
    • 2008
  • Slotless linear brushless DC motor are widely used in precision machine applications because of their advantages such as low of detent force, negligible iron loss. But they have a disadvantage such as low thrust density, thrust ripple, and excessive use of permanent magnet materials. These lead to undesirable performance and high production cost. In this paper, we deal with the design and characteristics investigation of a air-core tubular linear brushless DC(TLBLDC) motor with air-core stator and permanent magnet mover. And to investigate the static and dynamic characteristics of air-core TLBLDC motor, the prototype machine is manufactured and analyzed by F.E.M. and Matlab simulink simulations. Especially, dynamic characteristics of air-core TLBLDC motor driven with 6 step inverter are simulated by F.E.M.coupling with external circuit and Matlab simulink program, and measured for the prototype motor. The simulation results are compared to the experimental results such as current waves, thrust and speed curve.

인버터 입력전류 분석을 이용한 유도전동기 고장진단 (Diagnosis of Induction Motor Faults Using Inverter Input Current Analysis)

  • 한정호;송중호;최규형
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.492-498
    • /
    • 2016
  • 운전 중인 유도전동기에 고장이 발생하면, 구동장치 등 전체 시스템에 2차적인 고장을 유발 시킬 수 있다. 이 경우 구동시스템의 신뢰도와 안전성이 저하되고, 경제적인 손실을 초래할 뿐만 아니라, 인명 피해의 위험 등 많은 문제가 발생할 수 있다. 따라서 유도전동기의 고장징후를 조기 감지하여 전체 시스템 고장을 방지할 수 있도록 하는 유도전동기 고장진단 방법이 필요하다. 본 논문은 유도전동기에서 고정자권선의 부분 단락과 회전자 바의 균열이 발생하는 경우, 인버터 입력전류를 분석하여 고장징후를 조기 감지하는 유도전동기 고장진단 방법을 제안한다. 제안한 고장진단 방법은 고정자 전류 3개를 모두 센싱해야 하는 기존 고장진단 방법과 달리, 인버터 입력전류 센서 한 개만으로 유도전동기 고장진단이 가능하다. 또한, 정상전류 주파수성분과 고장전류 주파수성분이 서로 분리되어 나타나는 인버터 입력전류 특성을 통해 기존 고장진단 방법보다 비교적 쉽고 확실한 고장진단이 가능하다. 시뮬레이션을 통하여 제안한 유도전동기 고장진단 방법의 우수성과 유효성을 확인한다.

계단응답을 이용한 유도 전동기 파라미터 식별 (Parameter Identification of Induction Motor from Step Response)

  • 전범호;노치원;류준형;이광원
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권4호
    • /
    • pp.151-157
    • /
    • 2001
  • This paper presents an identification method of parameters of induction motor which is driven by PWM voltage inverter. The method uses least square estimation based on the step voltage input and current response. Utilizing the fact that ratio of two characteristic roots is large in the induction motor circuit, we derived two 1st-order difference equations for direct computation of parameter values. experimental results are compared with conventional motor test results to demonstrate that the proposed method is capable of estimating parameters of induction motor at standstill.

  • PDF

벡터제어 유도전동기의 최대효율 운전 (Maximum Efficiency Drive of Vector-Controlled Induction Motors)

  • 윤덕용;최규하;홍순찬;백수현;이은웅
    • 전력전자학회논문지
    • /
    • 제1권1호
    • /
    • pp.27-37
    • /
    • 1996
  • This paper proposes the control algorithm for maximum efficiency drive of PWM inverter - induction motor system with high dynamic performance. If the induction motor is driven under light load with rated magnetizing current, the Iron loss is excessively large compared with the codder loss which results in doer motor efficiency. Maximum efficiency drive of an induction motor can be achieved by controlling the magnetizing current to satisfy the optimal ratio that leads the total motor loss to be a minimum value at a given speed. The proposed control algorithm essentially uses vector control technique and adopts voltage decoupling control strategy to prevent the degradation of dynamic performance due to reduced magnetizing current. To verify the proposed method, digital simulations and experiments are carried out for a squirrel-cage induction motor with the rating of 2.2[kW].

  • PDF

Resonance Suppression using Sensorless Control of Dual SPMSMs Fed by Single Inverter

  • Eom, Jae-Boo;Choi, Jong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2376-2384
    • /
    • 2018
  • To reduce the size and cost of motor driving systems, several methods for driving multiple parallel-connected motors with a single inverter have been proposed. However, dual PMSMs driven by a single inverter, unlike induction motors, have a problem with instability due to system resonance caused by disturbances such as load imbalance and tolerances between two motors. To drive dual SPMSMs fed by a single inverter, this paper proposes an active damping algorithm to effectively suppress resonance by using one-sided sensorless speed control and position difference estimation. By deriving rotor position difference from d-q current differences between two motors, the proposed method is affected less by position difference estimation errors and is simpler than dual sensorless position estimation.