• Title/Summary/Keyword: Motor Cooling

Search Result 296, Processing Time 0.025 seconds

Implementation of Position Sensorless Stroke Controller of Linear Compressors with Motor Parameter Identification (매개변수 추정기를 갖는 리니어 컴프레서의 위치센서리스 스트로크 제어기 구현)

  • Kim, Kwang-Ho;Nam, Jae-Woo;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.173-179
    • /
    • 2014
  • In this paper, a motor parameter identification system has been implemented to improve the performance of the position sensorless stroke controller for linear compressors. In order to control the cooling capability of a refrigerator or an air conditioner in which linear compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. The dynamic performance of linear compressors depends on how accurately the stroke or the piston amplitude is estimated. The merits and demerits of Constant method and PIM (Parameter Identification Method) concerning the needed memory space and the stroke error are discussed and verified via some experimental studies.

Control of C-dump Converters fed from Switched Reluctance Motors on an Automotive Application

  • Yoon Yong-Ho;Kim Yuen-Chung;Song Sang-Hoon;Won Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.120-128
    • /
    • 2005
  • This paper deals with the analysis of switched reluctance motor drives for different drive circuit topologies used in automobile. So we attempt to improve the weaknesses associated with the asymmetric bridge converter in the limited internal environment of automotive application. Two kinds of c-dump converters are tested in terms of dump capacitor voltage, speed response according to the variation of advance angle and efficiency for the radiator cooling-fan drive of an automobile. They enable more economical and efficient converter topology for automobile industries. This paper describes the performance characteristics of 12V-250W-3000rpm SRM drives for automotive application. Computer simulation and experiment results are then presented to verify the performance of the two kinds of c-dump converters.

HEATING PERFORMANCE OF AIR SOURCE HEAT PUMP WITH HEAT REGENERATIVE DEVICE USING FIBER BELT

  • Ryou, Y.S.;Chang, J.T.;Kim, Y.J.;Kang, G.C.;Yun, J.H.;Lee, K.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.647-653
    • /
    • 2000
  • In this research the heat regenerative technology was employed to eliminate frosting on evaporator coil and improve COP of the heat pump system. This heat regenerative device(HRD) has very simple structure consisting a geared motor and a porous fiber belt passing through alternatively between cold and warm air duct. The laboratory test showed that the heat pump system with HRD yielded an impressive COP higher than 3.5 at the outside air temperature of $-7^{circ}C$ in heating mode.

  • PDF

OPTIMIZATION ON VEHICLE FUEL CONSUMPTION IN A HIGWAY BUS USING VEHICLE SIMULATION

  • Lyu, M.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.7
    • /
    • pp.841-846
    • /
    • 2006
  • This paper presents a numerical approach to optimizing vehicle fuel economy in a higway bus. The method described is based on using a commercial software vehicle simulation to identify the relative efficiency of each of the vehicle systems, such as the engine hardware, engine software calibration, transmission, cooling system and ancillary drives. The simulation-based approach offers a detailed understanding of which vehicle systems are underperforming and by how much the vehicle fuel economy can be improved if those systems are brought up to best-in-class performance. In this way, the optimum vehicle fuel economy can be provided to the vehicle customer. A further benefit is that the simulation requires only a minimum number of vehicle testing for initial validation, with all subsequent field test cycles performed in software, thereby reducing development time and cost for the manufacturer.

Development of Turboblower for Fuel Cell Automobile Applications (연료전지 자동차용 터보블로어 개발)

  • Kwon Hyuckroul;Park Hyungkeun;Kim Seongkyun;Kim Chimyung;Park Yongsun;Hwang Inchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.345-348
    • /
    • 2005
  • 본 개발의 목적은 연료전지차량에 탑재되는 연료전지 시스템에 장착될 공기공급기를 개발하는 것이었다. 개발된 공기공급기의 형태는 공급해야 할 공기의 유량과 압력 범위, 소음 및 향후 양산성 등을 고려하여 원심형 블로어를 선택하였으며, 차량 부하에 따른 공기공급량을 제어하기 위한 제어기도 적용되었다. 또한 차량에 적용될 경우, 예상되는 가혹한 사용환경에서 안정적인 성능을 발휘하고, 내구성을 할 수 있도록 설계되었으며, 특히, 외기온도 $45^{\circ}C$에서도 충분한 방열성능을 갖도록 모터 및 모터 방열구조를 설계하였다. 이를 위하여 공급되는 공기로 직접 모터를 냉각하는 개념을 적용하였다. 개발된 터보블로어의 응답성을 포함한 성능평가를 수행하였으며, 설계점에서 600시간 연속운전을 통하여 기본 내구평가를 완료하였다.

  • PDF

Control of Linear Compressor System Using Virtual AC Capacitor

  • Park, Shin-Hyun;Choi, Jong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2317-2323
    • /
    • 2017
  • Recently, linear compressors of cooling systems such as refrigerators, which have a free piston driven by a linear motor, have attracted much attention because of their high efficiency. For structural reasons, linear compressors applied in refrigerators should use an AC capacitor to ensure stable control. However, AC capacitors are expensive and bulky. In this paper, we propose a new method to realize stable control without a real AC capacitor by implementing a virtual AC capacitor with software. To realize a virtual AC capacitor, a pure integral is calculated. Nonetheless, if an offset current exists, the calculation may diverge to infinity. To solve this problem, a high-pass filter is applied and the compensation for the phase angle and magnitude are realized with a new method. Finally, a virtual AC capacitor enables variable frequency operations. Hence, in case of a lack of voltage, we can compensate by running the linear compressor in high-frequency operations. To improve efficiency, we may optimize the operation frequency. The validity of a virtual AC capacitor has been verified through simulations and experimental results.

Numerical Study on Preform Injection Molding for the PET Bottles Manufacturing (PET 용기 제작을 위한 프리폼 사출 성형에 대한 수치적 연구)

  • Kwon, Chang-Oh;Kim, Jong-Deok;Kim, Jeong-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.4
    • /
    • pp.285-289
    • /
    • 2007
  • This study presents the preform injection molding of the injection stretch-blow molding process for PET bottles. The numerical analysis of the injection molding of a preform is considered in this paper using CAE with a view to minimize the warpage. In order to determine the design parameters and processing conditions in injection molding, it is very important to establish the numerical model with physical phenomenon. In this study, a three dimensional model has been introduced for the purpose and flow simulations of filling, post-filling and cooling process are carried out. The simulations resulted in the warpage in good agreement with the measurements. Also, from the result of numerical analysis, we appropriate -ly predicted the warpage, deformation and thickness distribution along the preform wall.

  • PDF

Power Conversion Unit for Hybrid Electric Vehicles (하이브리드 전기자동차 구동용 전력변환장치)

  • Lee, Ji-Myoung;Lee, Jae-Yong;Park, Rae-Kwan;Chang, Seo-Geon;Choi, Kyung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.7-11
    • /
    • 2008
  • This paper describes design procedure and control strategy of HDC(High side DC/DC Converter) and MCU(Motor Control Unit) for diesel hybrid electric vehicle. In designing HDC and MCU for HEV high power density and reliability is strongly needed to meet the demand of automotive industry. In order to achieve the high performance of a controller, MPC5554 based control board is developed. An optimized film capacitor and inductor are also developed for high efficiency driving. Skim 63 IGBT module of SEMIKRON for automotive is used for power switching device. The most efficient cooling model for optimal size and reliability were verified by simulation. These procedures are verified by bench or driving test and the results are present in this paper.

  • PDF

An Experimental Study for the 77K Inertance Tube Pulse Tube Cryocooler (77K Inertance tube 맥동관 극저온 냉동기에 관한 연구)

  • Park, Seong-Je;Go, Deuk-Yong;Kim, Hyo-Bong
    • 연구논문집
    • /
    • s.29
    • /
    • pp.17-27
    • /
    • 1999
  • The experimental results of the 17K inertance tube pulse tube cryocooler for cooling cryosensors are presented in this paper. In prototype experiments, linear compressor is driven by linear motor, and inertance tubes are inserted between one liter reservoir and pulse tube. Design of the inertance tube pulse tube cryo-cooler is conducted by ARCOPTR program of NASA Ames Research Center. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature and refrigeration capacity according to the variations of inertance tube volume, reservoir volume and charging pressure are measured. and the cool down and load characteristics at the particular conditions are presented. As the representative results, no load temperature of the cold end is 52.7K and refrigeration capacity is 5W at 72K..

  • PDF

A study on the Characteristics of the Blowing type Rotary Burner (송풍형 로터리 버너의 특성 연구)

  • Choi Y. H.;Kim K. H.;Yoon S. J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.303-306
    • /
    • 2002
  • Liquid atomization by means of a spinning cup is widely used as a device for combustion, in cooling and spray drying. In this study, the blowing type rotary atomizer was experimental carried out the investigations on the characteristics of the blowing type rotary atomizer which is an air flow energy of blower instead of an electric motor most commonly used to a driven energy. The analysis on the rotary cup speed, air velocity with the blower conditions was performed and also the drop size was measured using LDPA. It was tried to analyzed on air-nozzle size and liquid flowrate as the result. It was found that the increase of the relative velocity between liquid and air improve significantly atomization liquid, and decrease of the liquid flowrate improved the maximum drop size though the mean drop size is really the same.

  • PDF