Developement of Measuring System of Circular Motion Accuracy in Machining Center (머시닝 센터에서 원운동정도 측정시스템의 개발)

  • 김영석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.3
    • /
    • pp.58-66
    • /
    • 1995
  • It is very important to test motion accuracy and performance of NC machine tools as they affect that of all other machines machined by them in industry. In this paper, in has become possible to detect errors of linear displacement of radial direction for circular motion test using newly assembled magnetic type of linear scales so called Magnescale ball bar system, and to calculate time interval getting error motion data and revolution angle of circular motion in machining center using tick pulses come out from computer. And a set of error data gotten from test is expressed to a plot by computer treatment and to numerics of error motion by statistical treatment and results of test are compared with those of Renishaw ball bar system.

  • PDF

Development of the Virtual Test Path for Eclipse-II, A Parallel Mechanism Motion Simulator (병렬구조 모션 시뮬레이터 이클립스-II 를 위한 가상현실 시험경로 개발)

  • 인우성;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.965-968
    • /
    • 2004
  • This paper describes the development of the test path for Eclipse-II, a parallel mechanism motion simulator. Eclipse-II which can be used as a base for general motion simulators, enables unlimited continuous 360-degree spinning in any rotational axes plus finite X, Y, and Z translation motions. The advantage of enabling continuous 360-degree spinning allows various motions for virtual reality. In this paper, the development of the test path to verify the robustness of the Eclipse-II motion simulator is described. The test motions, which satisfy the requirements of test path, are suggested and washout filter enables these motions reproduced in the limited workspace. The trial run is conducted to verify the robustness of the Eclipse-II motion simulator. Additionally the standard data format of virtual reality for Eclipse-II One Man Ride is suggested.

  • PDF

Developement of Measuring Units of circular Motion Accuracy on NC Lathe (NC선반의 원 운동정도 측정장치의 개발)

  • 김영석;김재열
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.1-7
    • /
    • 2001
  • It is very important to test circular motion accuracy of NC machine tools as it affects all other machines machined by them in industries. In this paper, it has become possible to detect errors of linear displacement of radial directions for circle tar motion accuracy test using newly assembled magnetic type of linear scale so called Magnescale ball-bar system. It has also organized computer program systems using tick pulses come out from computer for getting error motion data at colt start time interval in circular motion test on NC lathe. Error data gotten from test is expressed to plots and analysed to numerics by various statistical treatments.

  • PDF

Motion Sensing System for Automation of Neuropsycological Test (신경인지 검사를 위한 모션 센싱 시스템)

  • Jo, Wonse;Cheon, Kyeong-Min;Rew, Keun-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.128-134
    • /
    • 2017
  • Until now, neuropsychological tests can diagnose the brain dysfunction, however, cannot distinguish the objective data of experiment enough to distinguish the relationships between brain dysfunction and cerebropathia. In this paper, an automatic cognitive test equipment system with 6-axis motion sensors was proposed for the automation of neuropsychological tests. Fist-Edge-Palm(FEP) test and Go-no go test were used to evaluate motor programming of frontal lobe. The motion data from the specially designed motion glove are transmitted wirelessly to a computer to detect the gestures automatically. The healthy 20 and 11 persons are investigated for the FEP and Go-No go test, respectively. The recognition rates of gestures of FEP and Go-No go test are min. 91.38% and 89.09%. In conclusion, the automations of cognitive tests are successful to diagnose the brain diagnostics quantitatively.

Motion Response Characteristics of Small Fishing Vessels of Different Sizes among Regular Waves

  • DongHyup Youn;LeeChan Choi;JungHwi Kim
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • The motion of small fishing vessels is significantly affected by small waves, leading to accidents, such as capsizing or sinking. This paper presents the results of two types of basin tests. The first test analyzed the characteristics of roll and pitch motions among regular waves with the same wave steepness using the drifting state of three (3G/T, 7G/T, 10G/T) small fishing vessels. The second test analyzed the motion characteristics of the 7G/T fishing vessel under different wave steepness. The first test showed that heave and roll motions are significant in the beam sea, while pitch motion is significant in the bow and stern seas. The second test shows that wave steepness has a linear relationship with roll and pitch motions in the bow and stern seas.

Appropriate Input Earthquake Motion for the Verification of Seismic Response Analysis by Geotechnical Dynamic Centrifuge Test (동적원심모형 시험을 이용한 부지응답해석 검증시 입력 지진의 결정)

  • Lee, Jin-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.209-217
    • /
    • 2013
  • In order to verify the reliability of numerical site response analysis program, both soil free-field and base rock input motions should be provided. Beside the field earthquake motion records, the most effective testing method for obtaining the above motions is the dynamic geotechnical centrifuge test. However, need is to verify if the motion recorded at the base of the soil model container in the centrifuge facility is the true base rock input motion or not. In this paper, the appropriate input motion measurement method for the verification of seismic response analysis is examined by dynamic geotechnical centrifuge test and using three-dimensional finite difference analysis results. From the results, it appears that the ESB (equivalent shear beam) model container distorts downward the propagating wave with larger magnitude of centrifugal acceleration and base rock input motion. Thus, the distortion makes the measurement of the base rock outcrop motion difficult which is essential for extracting the base rock incident motion. However, the base rock outcrop motion generated by using deconvolution method is free from the distortion effect of centrifugal acceleration.

Effects of Ankle Self-Mobilization with Movement Intervention on Ankle Dorsiflexion Passive Range of Motion, Timed Up and Go Test, and Dynamic Gait Index in Patients with Chronic Stroke

  • Park, Donghwan
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.257-262
    • /
    • 2021
  • Objective: Patients with stroke generally diminished ankle range of motion, which decreases balance and walking ability. This study aimed to determine the effect of ankle self-mobilization with movement (s-MWM) on ankle dorsiflexion passive range of motion, timed up and go test, and dynamic gait index in patients with chronic stroke. Design: Randomized controlled trial design Methods: Twenty-four post-stroke patients participated in this study. The participants were randomized into the control (n = 12) and self-MWM groups (n = 12). Both groups attended standard rehabilitation therapy for 30 minutes per session. In addition, self-MWM group was performed 3 times per week for 8 weeks. All participants have measured ankle dorsiflexion passive range of motion, timed up and go test, and dynamic gait index in before and after the intervention. Results: After 8 weeks of training, self-MWM group showed greater improvement in ankle dorsiflexion passive range of motion, timed up and go test, and dynamic gait index than in the control group (p<0.05). Further, self-MWM group had significantly improvement in all dependent variables compared to the pre-test (p<0.05). Conclusions: Our investigation demonstrates that self-MWM is beneficial for improving functional ability. Also, self-MWM was superior to control with respect to improving ankle dorsiflexion passive range of motion, timed up and go test, and dynamic gait index.

Performance Evaluation of Fin-Stabilizer by Model Test and Time-domain Simulation (시뮬레이션과 모형시험을 통한 핀 안정기의 성능평가)

  • 홍사영;김현조;최윤락;신영균;유병석;이승준
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.86-90
    • /
    • 2001
  • Demand of good seakeeping perfomace is increasing for sea going vessels such as cruisers, naval ships and container ships. Especillay roll motion is one of major concerns in evaluation of seakeeping performance due to its large resonace motion. Since large roll resonance motion is mainly arised from inherent small damping. use of additional mechnism to provide roll damping can significantly reduce roll motion. In this paper, a reliable performace evaluation method of fin stabilizer, which is very useful for stabilizing roll motion of mid and high speed vessls, is described. Model test and time domain simulation methods are adopted for performance evaluation in which real operating situation of fin stabilizer can be exactly modelled. Model test and simulation results show good correlations between model test and simulation results.

  • PDF

The Effect of Continuous Passive Motion and Continuous Active Motion on Joint Proprioception After Total Knee Replacement (슬관절전치환술 후 연속수동운동(CPM)과 연속능동운동(CAM) 적용이 관절 고유수용감각에 미치는 영향)

  • Yang, Jin-Mo;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.1_2
    • /
    • pp.41-52
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the effects of continuous passive motion(CPM) and continuous active motion(CAM) on proprioception of the knee after total knee replacement(TKR). Methods: Twenty patients with TKR were randomly allocated into two groups, the CPM group(n=10) and the CAM group(n=10). All subjects were evaluated for levels of pain, passive range of motion and angle reproduction of the knee. An angle reproduction test was used to assess the proprioceptive deficit. Two types of angle reproduction test were used: a passive angle reproduction(PAR) test and an active angle reproduction(AAR) test. The relevant examinations were performed before and after intervention(on the 5th day and the 10th day). The statistical significance were calculated using a t-test and a one-way repeated ANOVA. Results: A pre-intervention significant difference was not found between the two groups. Significantly better results were before and after the intervention at 10 days, for the PAR(flexion direction) test; however, only in the CAM group. There were no significant difference, either before or after the intervention, for the AAR test(flexion and extension direction) in both group. Both groups experienced similar levels of pain and passive range of knee motion before and after the intervention. Conclusion: This study revealed that CAM was a better effect to restore position sense of the knee joint after TKR.

  • PDF

Deciding a sampling length for estimating the parameters in Geometric Brownian Motion

  • Song, Jun-Mo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.3
    • /
    • pp.549-553
    • /
    • 2011
  • In this paper, we deal with the problem of deciding the length of data for estimating the parameters in geometric Brownian motion. As an approach to this problem, we consider the change point test and introduce simple test statistic based on the cumulative sum of squares test (cusum test). A real data analysis is performed for illustration.