• Title/Summary/Keyword: Motion monitoring system

Search Result 288, Processing Time 0.031 seconds

A Study on Wearable Emergency Medical Alarm System (착용형 응급의료 경보시스템 구현에 관한 연구)

  • Kim, Dong-Wan;Beack, Seung-Hwa
    • Journal of IKEEE
    • /
    • v.10 no.1 s.18
    • /
    • pp.55-61
    • /
    • 2006
  • In modern society, development of medical technology has extended the human life span. However, it has also caused some side-effects. Mostly old people who live alone are not available the medical service quickly when they are in emergency situations. Moreover heart related diseases as well are rapidly increasing with aging. This study proposes the emergency medical alarm system. This system measures the physiological signals such as ECG(electrocardiogram), temperature, and motion data, analyzes those data automatically, and sends the urgent message to the Emergency Medical Center and to their family. There are two main parts in the system. In the first part, physiological data acquisition part, the troublesome addition and deletion of body signals on existing proposed systems have been supplemented, which led to the modulized production by means of ECG sensor module, temperature sensor module, acceleration sensor module. The other part is mobile unit, which includes signal processing and transmission functions. And bluetooth allows two parts to communicate with each other. Data that are processed in the mobile unit are stored in the PC database through the WLAN using TCP/IP protocol.

  • PDF

Estimation of Internal Motion for Quantitative Improvement of Lung Tumor in Small Animal (소동물 폐종양의 정량적 개선을 위한 내부 움직임 평가)

  • Yu, Jung-Woo;Woo, Sang-Keun;Lee, Yong-Jin;Kim, Kyeong-Min;Kim, Jin-Su;Lee, Kyo-Chul;Park, Sang-Jun;Yu, Ran-Ji;Kang, Joo-Hyun;Ji, Young-Hoon;Chung, Yong-Hyun;Kim, Byung-Il;Lim, Sang-Moo
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • The purpose of this study was to estimate internal motion using molecular sieve for quantitative improvement of lung tumor and to localize lung tumor in the small animal PET image by evaluated data. Internal motion has been demonstrated in small animal lung region by molecular sieve contained radioactive substance. Molecular sieve for internal lung motion target was contained approximately 37 kBq Cu-64. The small animal PET images were obtained from Siemens Inveon scanner using external trigger system (BioVet). SD-Rat PET images were obtained at 60 min post injection of FDG 37 MBq/0.2 mL via tail vein for 20 min. Each line of response in the list-mode data was converted to sinogram gated frames (2~16 bin) by trigger signal obtained from BioVet. The sinogram data was reconstructed using OSEM 2D with 4 iterations. PET images were evaluated with count, SNR, FWHM from ROI drawn in the target region for quantitative tumor analysis. The size of molecular sieve motion target was $1.59{\times}2.50mm$. The reference motion target FWHM of vertical and horizontal was 2.91 mm and 1.43 mm, respectively. The vertical FWHM of static, 4 bin and 8 bin was 3.90 mm, 3.74 mm, and 3.16 mm, respectively. The horizontal FWHM of static, 4 bin and 8 bin was 2.21 mm, 2.06 mm, and 1.60 mm, respectively. Count of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.10, 4.83, 5.59, 5.38, and 5.31, respectively. The SNR of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.18, 4.05, 4.22, 3.89, and 3.58, respectively. The FWHM were improved in accordance with gate number increase. The count and SNR were not proportionately improve with gate number, but shown the highest value in specific bin number. We measured the optimal gate number what minimize the SNR loss and gain improved count when imaging lung tumor in small animal. The internal motion estimation provide localized tumor image and will be a useful method for organ motion prediction modeling without external motion monitoring system.

Development of float off Operation Design for Mdlti Semi-submersible Barges with Symmetrical Stability Casings (반 잠수식 복수부선의 진수설계)

  • 양영태;최문길;이춘보;박병남;성석부
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.72-76
    • /
    • 2003
  • This paper presents the design concept and operation results of float-off for FSO (340,000 DWT Class, ELF AMENAM KPONO Project) built on the ground, without dry dock facilities. It was the first attempt to build FSO, completely, on the ground and launch it using DBU (Double Barge Unit, which was connected by rigid frame structure.) The major characteristics of FSO, which are similar to general VLCC type hull, including topside structure, weigh 51,000 metric ton. In order to have sufficient stability during the deck immersion of DBU, while passing through a minimum water plane area zone, proper trim control was completed with LMC (Load Master Computer). The major features of the monitoring system include calculation for transverse bending moment, shear force, local strength check of each connector, based on component stress, and deformation check during the load-out and float-off. Another major concern during the operation was to avoid damages at the bottom and sides of FSO, due to motion & movement after free-floating; therefore, adequate clearances between DBU and FSO were to be provided, and guide posts were installed to prevent side damage of the DBU casings. This paper also presents various measures that indecate the connector bending moment, damage stability analysis, and mooring of DBU during float off.

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

Abnormal Detection of CTLS Aircraft Wing Structure using SWT (SWT를 이용한 CTLS항공기 날개 구조물 이상탐지)

  • Shin, Hyun-Sung;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.359-366
    • /
    • 2018
  • In this paper, the noise is removed by using CTLS aircraft installed FBG sensor inside the aircraft wing. We suggest a normal wavelet transform scheme with motion - invariant characteristics for noise reduction. In the case of installing FBG sensors inside the composite material as in CTLS, large and small empty spaces and parts or sections are generated between the adhesive layers, and a signal splitting problem occurs. FBG sensor is not affected by noise. but eletromagnetic, light source, light detector and signal processing device are influeced by noise because these are eletronic components what affected by eletromagnetic wave. because of this, errors are occured. Experimental results show that the noise can be removed using normal wavelet transform and more accurate data detection is possible.

Real-Time Object Segmentation in Image Sequences (연속 영상 기반 실시간 객체 분할)

  • Kang, Eui-Seon;Yoo, Seung-Hun
    • The KIPS Transactions:PartB
    • /
    • v.18B no.4
    • /
    • pp.173-180
    • /
    • 2011
  • This paper shows an approach for real-time object segmentation on GPU (Graphics Processing Unit) using CUDA (Compute Unified Device Architecture). Recently, many applications that is monitoring system, motion analysis, object tracking or etc require real-time processing. It is not suitable for object segmentation to procedure real-time in CPU. NVIDIA provide CUDA platform for Parallel Processing for General Computation to upgrade limit of Hardware Graphic. In this paper, we use adaptive Gaussian Mixture Background Modeling in the step of object extraction and CCL(Connected Component Labeling) for classification. The speed of GPU and CPU is compared and evaluated with implementation in Core2 Quad processor with 2.4GHz.The GPU version achieved a speedup of 3x-4x over the CPU version.

Reliability Improvement of In-Vehicle Networks by Using Wireless Communication Network and Application to ESC Systems (무선 통신 네트워크를 이용한 차량 내 네트워크의 신뢰성 개선 및 ESC 시스템에의 응용)

  • Lee, Jeong Deok;Lee, Kyung-Jung;Ahn, Hyun-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1448-1453
    • /
    • 2015
  • In this paper, we propose an alternative method of communication to improve the reliability of in-vehicle networks by jointly using wireless communication networks. Wired Communication networks have been used in vehicles for the monitoring and the control of vehicle motion, however, the disconnection of wires or hardware fault of networks may cause a critical problem in vehicles. If the network manager detects a disconnection or faults in wired in-vehicle network like the Controller Area Network(CAN), it can redirect the communication path from the wired to the wireless communication like the Zigbee network. To show the validity and the effectiveness of the proposed in-vehicle network architecture, we implement the Electronic Stability Control(ESC) system as ECU-In-the-Loop Simulation(EILS) and verify that the control performance can be kept well even if some hardware faults like disconnection of wires occur.

Development of Laser Welding Technology for Commercial Vehicle Oil Pressure Sensor (상용차 오일압력 측정용 압력센서 제작을 위한 레이저용접기술)

  • Lee, Young-Min;Kim, Soon-Dong;Cho, Hae-Woon
    • Journal of Welding and Joining
    • /
    • v.30 no.4
    • /
    • pp.38-43
    • /
    • 2012
  • Using a fiber laser heat source, an oil pressure sensor was fabricated to measure the pressure in commercial vehicles. A stepping motor was used for the rotational and translational motion in the diaphragms and hardware joining. Laser welding process algorism including shielding gas control and vision system was integrated by using LabVIEW software for the high quality welding and in-line monitoring purpose. For the maximum flexibility in pressure transmission to the pressure sensor, thin sheet metal diaphragm, $25{\sim}50{\mu}m$(SUS-316L), was used and the diaphragms were optimally designed with FEM analysis. The welded samples were cross-sectioned the observation showed that the maximum depth ratio was more than seven times of diaphragms. The maximum welding speed was measured to be as high as 50in/mm by the developed automation mechanism. The fabricated prototypes were tested for the proof pressure, spring constant and sealing. The FEM results of spring constant measurement was as accurate as up to 80% of the design value and the sensor was safely operated up to the nominal pressure of 10bars.

Seismic fragility analysis of conventional and viscoelastically damped moment resisting frames

  • Guneyisi, Esra Mete;Sahin, Nazli Deniz
    • Earthquakes and Structures
    • /
    • v.7 no.3
    • /
    • pp.295-315
    • /
    • 2014
  • This paper presents the results of an analytical study on seismic reliability of viscoelastically damped frame systems in comparison with that of conventional moment resisting frame systems. In order to exhibit the reliability of the frame systems with viscoelastic dampers, seismic reliability analyses were carried out for steel framed buildings, 5 and 12 storeys in height, designed as: (a) Case 1: Conventional moment resisting frame, (b) Case 2: Frame with viscoelastic dampers providing supplemental effective damping ratio of 10%, and (c) Case 3: Frame with viscoelastic dampers providing supplemental effective damping ratio of 20%. Nonlinear time history analyses were utilized to develop seismic fragility curves whilst monitoring various performance objectives. To obtain robust estimators of the seismic reliability, a database including 15 natural earthquake ground motion records with markedly different characteristics was employed in the fragility analysis. The results indicate that depending upon the supplemental effective damping ratio, frames designed with viscoelastic dampers have considerably lower annual probability of exceedance of performance limit states for structural components, showing up to a five-fold reduction in comparison to conventionally designed moment resisting frame system.

Conditions to avoid synchronization effects in lateral vibration of footbridges

  • Andrade, Alexandre R.;Pimentel, Roberto L.;Silva, Simplicio A. da;Souto, Cicero da R.
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.2
    • /
    • pp.201-220
    • /
    • 2022
  • Lateral vibrations of footbridges may induce synchronization between pedestrians and structure itself, resulting in amplification of such vibrations, a phenomenon identified by lock-in. However, investigations about accelerations and frequencies of the structural movement that are related to the occurrence of synchronization are still incipient. The aim of this paper is to investigate conditions that could lead to avoidance of synchronization among pedestrians themselves and footbridge, expressed in terms of peak acceleration. The focus is on the low acceleration range, employed in some guidelines as a criterion to avoid synchronization. An experimental campaign was carried out, employing a prototype footbridge that was set into oscillatory motion through a pneumatic exciter controlled by a fuzzy system, with controlled frequency and amplitude. Test subjects were then asked to cross the oscillating structure, and accelerations were simultaneously recorded at the structure and at the subject's waist. Pattern and phase differences between these signals were analysed. The results showed that test subjects tended to keep their walking patterns without synchronization induced by the vibration of the structure, for structural peak acceleration values up to 0.18 m/s2, when frequencies of oscillation were around 0.8 to 0.9 Hz. On the other hand, for frequencies of oscillation below 0.7 Hz, structural peak accelerations up to 0.30 m/s2 did not induce synchronization.