• Title/Summary/Keyword: Motion kinematics

Search Result 542, Processing Time 0.025 seconds

A Study on Kinematic Analysis of Trunk and Lower Extremities in Stance Phase of Walking according to Turning Direction (보행 방향 전환 시 입각기 하지 및 체간의 운동형상학적 분석)

  • Oh, Tae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.2
    • /
    • pp.88-95
    • /
    • 2013
  • Purpose: The purpose of this study was to conduct an analysis of kinematics of lower extremities and trunk in stance phase of walking according to turning direction. Methods: Ten university students (five male, five female) who were in their 20s (mean age was 20.6 years old) participated in this study. Participants did not have participants did not have any problem with skeletal muscular system. We used the "Qualisys motion capture system" for analysis of trunk and lower extremity movement in stance phase of walking according to turning direction. We collected data while subjects walked a distance of 10 m, and at the 6 m line, subjects were required to turn to the left side and the right leg was positioned in stance phase and the left leg was positioned in swing. For data analysis, the SPSS for Windows ver. 20.0 statistics program was used in performance of one way analysis of variance according to turning direction. Results: Significant difference of trunk and lower extremities was observed for turning direction according to walking cycle (p<0.05). Upper trunk movement showed a greater increase at three dimensions than lower trunk, and in heel off phase, pelvic movement showed a greater increase than lower trunk (p<0.05). In 45 degree and 90 degrees of turning direction, all movements of trunk and lower extremities were significantly different among three events of stance phase (p<0.05). Conclusion: We suggest that three-dimensional movement analysis of trunk and lower extremities during turning movement was very important in order to indicate increasing balance or walking ability for people with impaired movement or walking.

An Analysis of Stress Pattern in the Coracoclavicular Ligaments with Scapular Movements: A Cadaveric Study Using Finite Element Model

  • Kim, Yoon Sang;Kim, In-Sung;Yoo, Yon-Sik;Jang, Seong-Wook;Yang, Cheol-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.152-158
    • /
    • 2015
  • Background: Acromioclavicular (AC) stability is maintained through a complex combination of soft-tissue restraints that include coracoclavicular (CC), AC ligament and overlying muscles. Among these structures, the role of the CC ligament has continued to be studied because of its importance on shoulder kinematics, especially after AC injury. This study was designed to determine the geometric change of conoid and trapezoid ligaments and resulting stresses on these ligaments according to various scapular motions. Methods: The scapuloclavicular (SC) complex was isolated from a fresh-frozen cadaver by removing all soft tissues except the AC and CC ligaments. The anatomically aligned SC complex was then scanned with a high-resolution computed tomography scanner into 0.6- mm slices. The Finite element model of the SC complex was obtained and used for calculating the stress on different parts of the CC ligaments with simulated movements of the scapula. Results: Average stress on the conoid ligament during anterior tilt, internal rotation, and scapular protraction was higher, whereas the stress on the trapezoid ligament was more prominent during posterior tilt, external rotation, and retraction. Conclusions: We conclude that CC ligament plays an integral role in regulating horizontal SC motion as well as complex motions indicated by increased stress over the ligament with an incremental scapular position change. The conoid ligament is the key structure restraining scapular protraction that might occur in high-grade AC dislocation. Hence in CC ligament reconstructions involving only single bundle, every attempt must be made to reconstruct conoid part of CC ligament as anatomically as possible.

The Effects of 12 Week Balance Ability Improvement Exercise to the Changes of Selected Joint Angles and Ground Reaction Forces during Down Staircase Walking (노인대상 12주간 균형능력 향상 운동이 계단 내리기 보행 시 주요 관절각 및 지면반력 변화에 미치는 영향)

  • Park, Yang-Sun;Kim, Eui-Hwan;Kim, Tae-Whan;Lee, Yong-Sik;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.267-275
    • /
    • 2010
  • The purpose of this study was to investigate the effects of balance ability improvement exercise program which applied to the elderly people for increasing balance, stability and range of motion. Ten elderly people and ten university students were recruited as the subjects. Kinematic data were collected by seven real-time infrared cameras while subjects walk stair descent as a pre-test. Korean folk dance exercise program was applied to the elderly for 12 weeks. Same experiment on stair descent walk was performed as post-test. Results indicated that CM movement and selected joint angle patterns of elderly group after treatment changed to the similar patterns of young group. However, ankle joint angle and vertical GRF of elderly group after treatment also increased compared to those of the elderly group before treatment. This might be explained by the fact that elderly used a different walking strategy which maximize support base for increasing stability. Overall, these results indicated that the exercise treatment may affect to adapt and improve the gait pattern of stair descent of elderly people.

Analysis of Muscle Activity of the Scapular Rotators With Changes of Shoulder Abduction Angle in Both Erect and Slouched Trunk Position (척주 기립자세와 굽힌자세에서 어깨관절 외전각도 변화에 따른 어깨뼈 주위 근 활성도 분석)

  • Kim, Duck-Hwa;Choi, Jong-Duk;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.11 no.1
    • /
    • pp.45-52
    • /
    • 2004
  • Altered scapular kinematics in the scapular joint is commonly believed to be a factor contributing to trunk posture. The purpose of this study was to analyze the muscle activity with several changes of the shoulder angle. Tests were performed on 10 male subjects by repeated measures. Each subject was measured while sitting in both erect and slouched trunk positions. In each sitting posture, a three-dimensional motion analysis measurement was used to measure thoracic angle and shoulder abduction angle. Measurements were taken with the shoulder abdcution angle at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, and $150^{\circ}$. By using surface Electromyography (EMG) electrodes, we recorded the activity of the upper trapezius, middle trapezius, lower trapezius, middle deltoid, and serratus anterior muscle while the subject held a 4 kg weight at each angle. The mean of root mean square (RMS) of EMG activity was calculated. The middle trapezius, lower trapezius, and middle deltoid muscle activity showed significantly higher results but serratus anterior muscle activity showed significantly lower results (p<.05). With the shoulder angle increased, the muscle activity was also significantly increased (p<.05). In conclusion, the thoracic spine posture significantly affects the scapular muscle during scapular plane abduction, and the slouched posture is associated with increased trapezius muscle activity and with decreased serratus anterior muscle activity.

  • PDF

Dynamic Characteristics of Helicopter Bearingless Main Rotor (헬리콥터 무베어링 주로터의 동특성 시험)

  • Yun, Chul Yong;Song, Keun Woong;Kim, Deog-Kwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.439-446
    • /
    • 2016
  • The characteristics of bearingless main rotor of helicopter are investigated through non-rotating tests and rotating tests. The stiffness and natural frequencies of rotor blades, flexbeam, and torque tube which are core components of baearingless rotor are measured to obtain input material properties for rotor analysis. The functional test on ground for assembly of one hub with damper, snubber, and no blade is carried out to check interfaces between components, kinematics of components, and pitch motion ranges under applied loads including centrifugal load. The 4-bladed bearingless rotor with 5.82m of rotor radius is tested on the whirl tower with rotation plane of 9.65m height. The thrust and power are measured to obtain hover performance and the frequencies and dampings of the rotor are obtained by excitation of cyclic pitch by hydraulic actuators.

Determination of In-Vivo Glenohumeral Translation During Loaded and Unloaded Arm Elevation

  • Nishinaka, Naoya;Mihara, Kenichi;Suzuki, Kazuhide;Makiuchi, Daisuke;Matsuhisa, Takayuki;Tsutsui, Hiroaki;Kon, Yoshiaki;Banks, Scott A.
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.44-44
    • /
    • 2009
  • The purpose of this study was to investigate humeral translation relative to the glenoid invivo during loaded and unloaded shoulder abduction. CT scans of 9 healthy shoulders were acquired and 3D models were created. The subject was positioned in front of a fluoroscope and motions were recorded during active abduction. The subjects performed two trials of holding a 3kg weight and unload. 3D motions were determined using model-based 3D-to-2D registration to obtain 6 degrees of freedom kinematics. Glenohumeral translation was determined by finding the location on the humeral head with the smallest separation from the glenoid. Humeral translation was referenced to the glenoid center in the superior/inferior direction. The humerus moved an average of 2 mm, from inferior to central on the glenoid, during arm abduction for both conditions. The humeral head was centered within 1mm from the glenoid center above $70^{\circ}$. There were no statistically significant differences for both conditions. The standard deviation decreased gradually over the motion, with significantly lower variability at the end of abduction compared to the initial unloaded position. We assumed that the humeral translation to the center of the glenoid provides maximum joint congruency for optimal shoulder function and joint longevity. We believe this information will lead to better strategies to prevent shoulder injuries, enhance rehabilitation, and improve surgical treatments.

  • PDF

In Vivo Three-Dimensional Evaluation of the Functional Length of Glenohumeral Ligaments

  • Yang, Chen;Goto, Akira;Sahara, Wataru;Koishi, Hayato;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.43-43
    • /
    • 2009
  • Glenohumeral ligaments play an important role in stabilizing the shoulder. However, it is impossible to know how they function in vivo during shoulder motion. To help elucidate this stabilizing role, we conducted in vivo three-dimensional kinematics of the normal shoulder joint using a markerless bone-registration technique. Magnetic resonance images of 14 shoulder joints of 7 healthy volunteers were acquired for 7 isometric abduction positions between $0^{\circ}$ and $180^{\circ}$. We then calculated three-dimensional shortest paths between the origin and insertion of each ligament based on anatomical study in each abduction position. At $0^{\circ}$ of abduction, the posterior band of the coracohumeral ligament displayed the maximum length. At $30^{\circ}$ of abduction, the superior glenohumeral ligament displayed the maximum length. At $60^{\circ}$ of abduction, the anterior band of the coracohumeral ligament and the middle glenohumeral ligament displayed the maximum length. At $120^{\circ}$ of abduction, the anterior band of the inferior glenohumeral ligament displayed the maximum length. We think that the maximum length of these results is an important influence on the function of the soft tissue stabilizer.

  • PDF

Acute Changes in Fascicle Behavior and Electromyographic Activity of the Medial Gastrocnemius during Walking in High Heeled Shoes

  • Kim, Jin-Sun;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.135-142
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the acute effect of walking on high heels on the behavior of fascicle length and activation of the lower limb muscles. Methods: Twelve healthy inexperienced high heel wearers (age: $23.1{\pm}2.0yr$, height: $162.4{\pm}4.9cm$, weight: $54.4{\pm}8.5kg$) participated in this study. They walked in high heels (7 cm) and barefoot on a treadmill at their preferred speed. During the gait analysis, the lower limb joint kinematics were obtained using a motion analysis system. In addition, the changes in fascicle length and the level of activation of the medial gastrocnemius (MG) were simultaneously monitored using a real-time ultrasound imaging technique and surface electromyography, respectively. Results: The results of this study show that the MG fascicle operates at a significantly shorter length in high heel walking ($37.64{\pm}8.59mm$ to $43.99{\pm}8.66mm$) in comparison with barefoot walking ($48.26{\pm}9.02mm$ to $53.99{\pm}8.54mm$) (p < .05). In addition, the MG fascicle underwent lengthening during high heel walking with relatively low muscle activation while it remained isometric during barefoot walking with relatively high muscle activation. Conclusion: Wearing high heels alters the operating range of the MG fascicle length and the pattern of muscle activation, suggesting that prolonged wearing of high heels might induce structural alterations of the MG that, in turn, hinder normal functioning of the MG muscle during walking.

Visualization of Virtual Slave Manipulator Using the Master Input Device (주 입력장치를 이용한 가상 슬레이브 매니퓰레이터의 시각화)

  • 김성현;송태길;이종열;윤지섭
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.388-394
    • /
    • 2003
  • To handle the high level radioactive materials such a spent fuel, the master-slave manipulators (MSM) are widely used as a remote handling device in nuclear facilities such as the hot cell with sealed and shielded space. In this paper, the Digital Mockup which simulates the remote operation of the Advanced Conditioning Process(ACP) is developed. Also, the workspace and the motion of the slave manipulator, as well as, the remote operation task should be analyzed. The process equipment of ACP and Maintenance/Handling Device are drawn in 3D CAD models using IGRIP. Modeling device of manipulator is assigned with various mobile attributes such as a relative position, kinematics constraints, and a range of mobility, The 3D graphic simulator using the external input device of space ball displays the movement of manipulator. To connect the external input device to the graphic simulator, the interface program of external input device with 6 DOF is deigned using the Low Level Tele-operation Interface(LLTI). The experimental result shows that the developed simulation system gives much-improved human interface characteristics and shows satisfactory response characteristics in terms of synchronization speed. This should be useful for the development of work's education system in the virtual environment.

  • PDF

LONG-SLIT SPECTROSCOPY OF PARSEC-SCALE JETS FROM DG TAURI

  • Oh, Heeyoung;Pyo, Tae-Soo;Yuk, In-Soo;Park, Byeong-Gon
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.113-123
    • /
    • 2015
  • We present observational results from optical long-slit spectroscopy of parsec-scale jets of DG Tau. From HH 158 and HH 702, the optical emission lines of Hα, [O i] λλ6300, 6363, [N ii] λλ6548, 6584, and [S ii] λλ6716, 6731 are obtained. The kinematics and physical properties (i.e., electron density, electron temperature, ionization fraction, and mass-loss rate) are investigated along the blueshifted jet up to 650′′ distance from the source. For HH 158, the radial velocity ranges from −50 to −250 km s−1. The proper motion of the knots is 0.′′196 − 0.′′272 yr−1. The electron density is ∼104 cm−3 close to the star, and decreases to ∼102 cm−3 at 14′′ away from the star. Ionization fraction indicates that the gas is almost neutral in the vicinity of the source. It increases up to over 0.4 along the distance. HH 702 is located at 650′′ from the source. It shows ∼ −80 km s−1 in the radial velocity. Its line ratios are similar to those at knot C of HH 158. The mass-loss rate is estimated to be about ∼ 10−7 M yr−1, which is similar to values obtained from previous studies.