• 제목/요약/키워드: Motion effects

검색결과 2,971건 처리시간 0.044초

가상현실 게임을 적용한 물리치료가 무릎 수술 후 환자의 통증, 기능 변화, 삶의 질, 동기부여에 미치는 영향 (Effects of Physical Therapy Combined with Virtual Reality Games on Pain, Function, Quality of Life, And Engagement in Post-Knee-Surgery Patients)

  • 김홍길;정주현
    • PNF and Movement
    • /
    • 제21권3호
    • /
    • pp.345-356
    • /
    • 2023
  • Purpose: The aim of this study was to investigate the effects of physical therapy combined with a virtual reality (VR) game on pain, quality of life (QOL), engagement, and knee function in post-knee-surgery patients. Methods: Twenty-four patients who had undergone knee surgery four weeks or more before the study were recruited. Two withdrew from the study during the four-week experimental period, and a total of 22 patients were included in the final analysis. Routine physical therapy consisting of electrostimulation (10 min.) and therapeutic massage (10 min.) was the base intervention for all groups. The experimental group (n = 10) was additionally exposed to a VR game intervention, while the control group (n = 12) underwent an intervention involving similar motions as the experimental intervention but with no VR. The intervention for the experimental group used the game Rig Fit Adventure on Nintendo switch. Both groups underwent their respective interventions 3 times a week (35 min. per session) for 4 weeks. Pain was assessed using the numeric rating scale (NRS), and QOL was assessed using the EuroQol five-dimensional five-level questionnaire (EQ-5D-5L). Engagement was assessed using the Korea flow state scale (K-FSS). Finally, knee movement and function were assessed based on knee flexion and extension, range of motion (ROM), and Western Ontario and McMaster Universities Arthritis Index (WOMAC). Results: After the four-week physical therapy, both groups showed significant reductions in pain (on the NRS), increased knee ROM (flexion), better WOMAC scores, and increased EQ-5D-5L scores (p < 0.05), with the experimental group showing significantly better improvements in EQ-5D-5L and K-FSS scores (p < 0.05). Conclusion: The results of this study confirm that a VR-game-integrated intervention is effective for improving pain, QOL, engagement, and knee function in post-knee surgery patients and that VR-game-integrated interventions could be therapeutic alternatives for patients bedridden for prolonged periods with little motivation for rehabilitation.

중학교 과학 수업에서 학생 질문을 촉진하는 방안으로서의 주단위 보고서의 효과 (The Effects of Weekly Reports as a Method for Encouraging Student Questions in Middle School Science Instruction)

  • 강훈식;이성미;권은경;노태희
    • 한국과학교육학회지
    • /
    • 제26권3호
    • /
    • pp.385-392
    • /
    • 2006
  • 이 연구는 학생들의 질문을 촉진하는 방안으로서의 주단위 보고서가 중학교 과학 수업에 미치는 영향을 개념 이해도, 학업 성취도, 개념도, 수업 처치에 대한 인식 측면에서 조사하였다. 중학교 1학년 211명을 통제 집단과 WR 집단으로 배치한 후, '물질의 세 가지 상태', '분자의 운동', '상태 변화와 에너지'에 대해 총 18차시 동안 수업을 실시하였으며, 이 기간 동안 학생들은 주단위 보고서를 총 6회 작성하였다. 연구 결과, 개념 이해도 검사에서는 WR 집단의 점수가 통제 집단의 점수보다 높았으며, 그 차이가 통계적으로 유의미하였다. 학습 전략에 따른 개념 이해도 점수를 비교한 결과, 피상적 전략을 사용하는 학생들의 경우 WR 집단의 점수가 통제 집단의 점수보다 높았으며, 그 차이가 통계적으로 유의미하였다. 심층적 전략을 사용하는 학생들의 경우에는 WR 집단의 점수가 통제집단의 점수보다 통계적으로 높은 경향성을 보였다. 학업 성취도 검사와 개념도 검사에서는 WR 집단의 점수가 통제 집단의 점수보다 높았고 그 차이가 통계적으로 유의미했으나, 수업 처치와 학습 전략에 따른 상호작용 효과는 유의미하지 않았다. 수업 처치에 대한 인식 검사 결과에서는 대부분의 학생들이 주단위 보고서에 대해 긍정적으로 인식하는 것으로 나타났다.

어깨뼈 운동 이상증을 가진 청소년기 야구선수들을 위한 물리치료적 프로그램: 어깨뼈 안정화 운동과 동반된 뒤쪽 어깨 스트레칭(PSSE) 중재 후 효과 비교 (A Physiotherapy Program for Adolescent Baseball Players with Scapular Dyskinesis: Comparison of the effects of posterior shoulder stretching combined with scapular stabilization exercises (PSSE))

  • 이건철;김현수;추연기
    • 대한통합의학회지
    • /
    • 제12권1호
    • /
    • pp.139-150
    • /
    • 2024
  • Purpose : Scapular dyskinesis, it have been shown to be common in overhead athletes and has been associated with RC muscle strength. Posterior shoulder tightness (PST) has been suggested as an important factor causing scapular dyskinesis. Therefore, rehabilitation programs should focus on a posterior shoulder stretch combined with scapular stabilization exercise (PSSE) intervention. Determine the effects of posterior shoulder stretch combined with scapular stabilization exercise on the rotator cuff (RC) muscles strength, functional strength ratio (FSR), range of motion (ROM), and pain. Methods : 30 adolescent baseball players participated and subjects were allocated PSSE group (n=15) or the SSE group (n=15). Both group performed a 6-weeks intervention and measured of isokinetic peak torque/body weight (PT/BW) of concentric external rotator (CER), eccentric external rotator (EER), concentric internal rotator (CIR), eccentric internal rotator (EIR), FSR, ROM, and pain. Results : After 6 weeks PSSE, significant increase CER PT/BW (+6.02±4.76 %), EER PT/BW (+5.39±4.22 %), EER to CIR ratio (+.17±.16), and internal rotation ROM (+15.08±3.57 °). Whereas, significant decrease EIR to CER ratio (-.14±.18), external rotation ROM (-12.00±6.94 °), and GIRD (-17.41±2.84 °) compared with pre-intervention. No significant difference of isokinetic PT/BW of CIR and EER post-intervention. In the SSE group showed no significant difference all measurements for isokinetic PT/BW, FSR, and ROM post-intervention. The pain was significant improve both PSSE group (-3.25±1.60) and SSE group (-2.83±1.85) post-intervention. Conclusion : Both the PSSE and SSE interventions led to more pain relief. However, only the PSSE group showed ROM, CER, EER PT/BW, and FSR improvements. These results might suggest that the PSSE intervention is a more effective program for improving RC muscle strength and balance, in particular, concentric and eccentric ER muscle strength, FSR and can expect to prevent shoulder injuries in adolescent baseball players with scapular dyskinesis.

상완골 후경각이 가동역에 따른 견관절 근력에 미치는 영향 (Effects of Shoulder Muscle Strength on Terminal Range by Humeral Head Retroversion)

  • 박시영;이동준
    • 생명과학회지
    • /
    • 제20권4호
    • /
    • pp.549-554
    • /
    • 2010
  • 어깨 관절의 외선의 증대와 내선의 감소는 야구 투수들의 어깨에 주의 깊게 발생한다는 것을 알아야한다. 본 연구의 목적은 MRI 진단을 통해 상완골 후경각을 판단하고, 야구 투수들에게 정해진 각도에서의 길항근의 신장성 수축과 주동근의 단축성 수축을 통한 근력을 비교 분석하는데 있다. 대상자는 어깨관절의 통증을 경험하지 않은 9명의 투수들을 선정하였고, 투구측과 비투구측을 어깨관절을 대상으로 등속성 시스템을 이용하여, $90^{\circ}/s$$180^{\circ}/s$의 속도로 어깨관절의 내선 $90^{\circ}$와 외선 $20^{\circ}$의 범위에서 근력측정을 하였다. 모든 데이터는 대응 t검정을 사용해 분석 및 평가를 하였다(p<0.05). 그 결과 투구측의 총 가동역은 $180.1^{\circ}$로 나타났으며, 비투구측은 $183.7^{\circ}$로 나타났다. 상완골 후경각은 투구측이 $47.6{\pm}6.1^{\circ}$로 나타났으며, 비투구측은 $37.8{\pm}5.3^{\circ}$로 유의한 차이를 보였다(p<0.05). 투구측의 내선근 단축성 수축력(IR-Con)은 $31.5{\pm}5.1\;Nm$로 나타났으며, 비투구측의 $38.7{\pm}5.2\;Nm$와 비교해 유의한 차이를 보였다(p<0.05). 투구측의 외선근 신장성 수축력(ER-Ecc)도 $20.3{\pm}4.7\;Nm$로 나타났으며, 비투구측의 $25.1{\pm}3.7\;Nm$에 비교해 통계학적으로 유의한 차이를 보였다(p<0.05). 결론으로는 본 연구의 검토를 통해 투수들의 어깨관절에 있어서 외선의 증대 및 내선의 감소는 상완골 후경각의 골성의 변화가 중요한 요인으로 나타났으며, 근력의 변화에도 중대한 영향을 미치는 것으로 나타났다.

물체 크기와 뻗기 거리가 상지 움직임에 미치는 영향 (The Effects of Object Size and Reaching Distance on Upper Extremity Movement)

  • 배수영;김태훈
    • 대한지역사회작업치료학회지
    • /
    • 제10권1호
    • /
    • pp.51-61
    • /
    • 2020
  • 목적 : 정상인을 대상으로 팔뻗기 수행 시 물체 크기와 뻗기 거리가 상지의 운동형상학적 요소에 미치는 영향을 알아보고자 하였다. 연구 방법 : 대상자는 부산시 D대학교에 재학 중인 대학생 30명이며 측정 도구는 삼차원 동작 분석기인 CMS-70P(Zebris Medizintechnik Gmbh, Germany)를 사용하였다. 과제는 6가지 조건이다. 팔뻗기 수행시 물체 크기(2cm, 10cm)와 뻗기 거리(15%, 37.5%, 60%)의 변화에 따른 움직임의 평균 속도, 평균 가속도, 최대 속도, 속도의 정점수를 측정하였다. 대상자의 일반적 특성은 기술통계를 사용하였다. 두 가지 물체 크기에서 세 가지 뻗기 거리로 팔뻗기 과제를 수행했을 때 변수를 비교하기 위해 일원분산분석(One-way ANOVA measure)으로 분석하였고, 사후검정은 Tukey 검정을 실시하였다. 또한 세 가지 뻗기 거리에서 두 가지 물체 크기에 따른 운동형상학적 차이를 분석하기 위해서 독립 t검정(Independent t-test)을 사용하였다. 팔뻗기 거리(15%, 37.5%, 60%)와 물체 크기(2cm, 10cm)에 따른 상호작용효과를 확인하기 위해 이원분산분석(3×2 Two-way ANOVA measure)을 실시하였다. 통계적 유의수준 α는 .05로 설정하였다. 결과 : 정상인은 물체 크기와 뻗기 거리의 변화에 따라 상지 움직임에 유의한 차이가 있었다. 물체 크기가 동일한 경우 뻗기 거리가 길어질수록 평균 속도, 최대속도가 증가하였고, 속도의 정점 수는 감소하였다. 뻗기 거리가 동일한 경우 물체 크기가 커질수록 평균 속도, 최대 속도가 증가하였고 속도의 정점 수는 감소하였다. 물체 크기와 뻗기 거리의 변화는 평균 가속도에 영향을 미치지 않았으며 유의한 차이가 없었다. 결론 : 과제를 시간적, 공간적 특성으로 제한하는 것은 대상자의 상지 움직임에도 영향을 미치게 된다. 따라서 본 연구의 결과를 토대로 신경학적 기능수준에 따라 세밀하게 등급화된 과제제공에 도움이 될 것으로 사료된다.

이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향 (Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft)

  • 이철우;유재두;노권재;박성필
    • 대한관절경학회지
    • /
    • 제9권2호
    • /
    • pp.143-147
    • /
    • 2005
  • 목적: 슬개 건을 이용한 전방 십자 인대 재건술 시, 이식 건을 경골 쪽에서 고정할 때 일반적으로 슬관절의 굴곡 각도는 신전 위치에서 시행한다. 저자들은 슬괵 건을 이용한 전방 십자 인대 재건술 시, 이식 건을 고정 할 때 슬관절의 굴곡 각도가 수술 후 슬관절 안정성과 운동 범위에 미치는 영향을 알아보고자 하였다. 대상 및 방법: 2002년 5월부터 2003년 1월까지 슬괵 건을 이용한 전방 십자 인대 재건술 시, Rigidfix system(Mitek Product, Johnson and Johnson, USA)와 intrafix를 이용하여 고정하였다. 전방 십자 인대 재건술을 시행 받은 39명 중 추시 관찰이 되지 않은 2명을 제외한 37명의 환자를 대상으로 하였다. 평균 추시 기간은 14개월(범위: $13{\sim}25$개월) 이었다. 완전 신전 위 또는 20도 굴곡 위의 슬관절 굴곡 각도의 결정은 수술 순서에 따라서 교대로 선택하였다. 내측 반월상 연골의 절제 2예, 내측 반월상 연골의 봉합 2예 외측 반월상 연골의 봉합 1예에서 시행하였다. 임상적 평가는 이학적 검사인 Lachman검사, Pivot shift검사와 재건술 후의 Lysholm점수, IKDC( international knee documentation committee)평가 기준, KT-1000관절 계측 결과를 이용하였다. 결과: 최종 추시 상 수술 후 Lysholm 점수는 93.1점(범위: $65{\sim}98$점), IKDC 평가 기준에 의한 최종 평가 상 정상(A) 26예, 거의 정상(B) 10예, 비정상(C) 1 예이었으며, 심한 비정상은 (D)은 없었다. 최종 추시 상 KT-1000 관절계를 이용한 최대 도수 부하 검사 상 건 측 과의 차이는 평균 2.5 mm 이였다. 술 후 시행한 Lachman 검사상 정상 32예, 1 등급 4예, 2 등급 II 1예 이었고, Pivot shift 검사 상 정상 34예, 1 등급 2예, 2 등급 1예 이었다. KT-1000 관절계를 이용한 최대 도수 부하 검사 상 건 측 과의 차이는 20도 고정을 한 경우는 평균 2.3 mm, 완전 신전 위에서 고정한 경우는 평균 2.7 mm이였다(P<0.05). 수술 후 1년 슬관절의 운동 범위는 20도 굴곡 위에서 고정한 경우에 1례 에서 5도의 굴곡 구축이 있었고, 신전 위에서 고정한 경우는 2례 에서 건측 보다 10도의 굴곡 제한이 있었다. 결론: 자가 슬괵 건을 이용한 전방 십자 재건술 시, 경골 부의 고정 시 슬관절의 굴곡 각도 따른 슬관절의 전방 안정성에 차이는 없었으나, 신전 위에서 고정하는 것이 과도한 이식 건의 장력으로 인한 슬관절 굴곡 구축을 예방하는데 도움이 될 것으로 사료된다.

  • PDF

상완와관절의 수동하방활주운동이 오십견환자의 외전운동과 관절 내 움직임에 미치는 영향 (The Effects of Glenohumeral Abduction Motion and Intra-articular Movement after Passive Caudal Gliding Mobilization in Frozen Shoulder Patients)

  • 서종학;배성수;김철용
    • The Journal of Korean Physical Therapy
    • /
    • 제15권3호
    • /
    • pp.126-152
    • /
    • 2003
  • The purpose of this study was to evaluate the value of passive caudal gliding mobilization of the glenohumeral joint on the range of motion (ROM) of active and passive abduction; to evaluate the value of pain relief through visual analogue scale (VAS); to evaluate the correlation between improvement of shoulder abduction and intra-articular movement measured by fluoroscopy in frozen shoulder patients. The subjects consisted of twenty-one patients with clinically diagnosed frozen shoulder (11 males, 10 females) between 40 and 63 years of age (mean age : 52.7 years). The traction and caudal gliding mobilization based on the convex-concave rule in the resting position and at end range of abduction was peformed for 15 minutes per day and was repeated 10 times during a 2 week period. The ROM of abduction was measured by goniometer and pain was measured by VAS. The intra-articular movement was measured by fluoroscope, Neurostar Plus TOP (Siemens, Germany). ROM measurements of each patient was acquired at pre-treatment, immediate post-treatment and 2 week post-treatment. Statistical analysis was performed using SPSS 10.0 for Windows software and data was analyzed using the paired-test and the pearson correlation. The results of this study are as follows: 1. There was a significant decrease of VAS between pre-treatment data and 2 week post-treatment data (P<.05) but no significant difference between pre-treatment and immediate post-treatment data (P>.05). 2. There was a significant increase in ROM of active and passive abduction in the pre-treatment data, immediate post-treatment data, and in 2 week post-treatment data (P<.05). 3. With regard to results of the joint play test, there was a significant difference in the grade of traction between pre-treatment data and immediate post-treatment data and between pre-treatment data and 2 week post-treatment data (P<.05). There was no significant difference between immediate post-treatment data and 2 week post-treatment data (P>.05). 4. With regard to results of the joint play test, there was a significant difference in the grade of caudal gliding between pre-treatment data and immediate post-treatment data and between pre-treatment data and 2 week post-treatment data (P<.05). There was no significant difference between immediate post-treatment data and 2 week post-treatment data (P>.05), 5. With regard to the results of fluoroscopic findings, there was a significant change of the glenohumeral joint space between pre-treatment data and immediate post-treatment data and between immediate post-treatment data and 2 week post-treatment data (P<.05). There was no significant change of the glenohumeral joint space between immediate post-treatment data and 2 week post-treatment data (P>.05). 6. With regard to the results of fluoroscopic findings, there was a significant change of acromiohumeral joint space between the three data (pre-treatment data, immediate post-treatment data, 2 week post-treatment data) (P<.05). 7. Mobility grade by joint play test was significantly increased and was correlated to improved ROM of active and passive abduction (P<.05). In this study of frozen shoulder, passive caudal gliding techniques of the glenohumeral joint results in statistically significant changes in active and passive abduction as well as in VAS. There is also a significant correlation between joint play test and ROM of abduction.

  • PDF

소아에서 도플러 조직영상을 이용한 최대 심근 속도의 계측 : 정상 추정치 및 성장 및 심박동수에 따른 변화 (Quantitative Assessment of Myocardial Tissue Velocity in Normal Children with Doppler Tissue Imaging : Reference Values, Growth and Heart Rate Related Change)

  • 김세영;현명철;이상범
    • Clinical and Experimental Pediatrics
    • /
    • 제48권8호
    • /
    • pp.846-856
    • /
    • 2005
  • 목 적 : 최근 심장 기능 평가에 많이 사용되는 TDI 지표들에 대해서 우리나라의 정상 소아에 대한 연구가 아직 미흡한 실정이다. 이에 정상 소아 72례(남아 : 42례, 여아 : 30례)를 대상으로 한 TDI 및 31례를 대상으로 한 M-형 심초음파 검사를 이용한 지표들에 대한 계측치를 확인하고, 이러한 계측치에 여러 변수들(몸무게, 심박동수, 측정한 위치 등)이 미치는 영향에 대해서 관찰하였다. 방 법 : 선천성 심질환이나 심장에 영향을 미칠 수 있는 질환이 없는 건강한 소아를 대상으로 하여, 심첨 4방도, 심첨 2방도의 여러 부위에서 PW-TDI를 이용하여 최대 심근 속도를 측정하고, 측정 부위에 따른 계측치의 차이, 나이, 몸무게 및 심박동수 등이 이러한 측정치들에 미치는 영향에 대해서 연구하였다. 또한 심첨 4방도에서 각각의 판막륜 방향으로 M-형 심초음파 검사를 시행하여 나이, 몸무게 및 심박동수와 연관 관계가 있는지 알아보았다. 또한 M-형 심초음파 검사에서 측정한 값들과 TDI 계측치들과의 관계에 대해서도 연구하였다. 결 과 : TDI로 측정한 여러 변수들은 남녀, 심초음파 기기간 및 검사를 시행한 의사간에는 의미있는 차이를 보이지 않았다. 판막륜과 판막륜 및 심첨의 중간 부위에서 측정한 값간에는 판막륜에서 측정한 값들이 의미있게 높게 측정되었으며, 우심실 측벽의 측정치가 심실 중격 및 좌심실 부위에서 측정한 값보다 높았다. 심근 단축률과 TDI 측정치간에는 상관 관계를 보이지 않았다. 심박동수와의 상관 관계를 보면 S-및 E-파형의 경우 심박동수와 상관 관계가 없었으나, A-파형 및 A/E 비는 심박동수와 양의 상관 관계를 보였다. 몸무게와의 상관 관계도 측정한 부위 및 계측치 들마다 일정한 상관 관계를 보여 주지는 못하였다. M-형 심초음파 검사로 측정한 판막륜의 움직임은 성별간에 유의한 차이를 보이지 않았으며, ALD는 몸무게와 양의 상관 관계를, 이동률은 음의 상관 관계를 보이는 경향이 있었다. 그러나 이동률과 TDI 계측치들 간에는 유의한 상관 관계를 발견할 수 없었다. 결 론 : 정상 소아들에서 TDI를 이용하여 최대 심근 속도를 측정하고, 또한 M-형 심초음파 검사를 이용한 판막륜의 움직임을 관찰해 보았다. 이러한 계측치들을 토대로 좀더 많은 례를 통한 한국 소아들의 TDI 및 M-형 심초음파 검사를 이용한 판막륜의 움직임에 대한 정상치를 확립하여야 하겠으며, 선천성 및 후천성 심질환을 가진 환아들에서의 임상 적용을 기대해 본다.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

용기의 보호환경에 따른 불수정란(웅성불임잠)의 유발기구에 관한 조사연구 (Studies on the mechanism in the induced to unfertilized eggs(male sterility of Silkworm) by protected environment during pupae period)

  • 윤종관;오준식
    • 한국잠사곤충학회지
    • /
    • 제15권2호
    • /
    • pp.9-14
    • /
    • 1973
  • 용기의 고온보호가 웅아의 생식력에 미치는 영향을 조사하기 위하여 9품종을 공시하여 유충기에는 각시험구 공히 보통육을 하고 화용후에는 일정기간을 고온(33$^{\circ}C$)에 보호하고 여기에 수원 103$\times$수원잠 104의 정상웅아를 교배하여 교미능력과 조사아수의 산하총란수에 대한 불수정비율 즉 웅성불임상황을 조사한 결과 다음과 같은 결과를 얻었다. 1) 용기의 고온보호는 상온에 비하여 웅아임의 불화가 현저히 나타나지만 그 출현율은 품종에 따라서 큰 차가 있다. 2)고온구는 상온구에 비하여 화아상태가 불량하다. 3) 교미능력은 수원잠계통에 비하여 모란 대동 일124 및 중108 등이 불량하다. 4) 외관상 수정능력이 있어 보이는 웅아도 이를 이용한 산하란의 수정상태를 보면 모란, 대동, 일124 및 중108 등에서는 65%내외의 불수정율을 나타냈다. 5) 용의 말기 1일간의 처리구에서는 10%내외의 불수정란율을 나타냈고 2일째 20%내외 3일째 35%내외 4일째 40~60% 5일째 68% 7일째 70%내외에 달하였다. 이러한 사실에 의하여 불임성의 출현양상은 용의 후기보다 큰영향이 미친다는 것을 알 수 있게 한다. 6) 고온처리 웅아와 교미시키고 5시간이 경과한 웅아에 대하여 그 교미낭과 수정낭내의 정자의 상태를 관찰한 결과 대조구에서는 생식계가 정상적이고 정자량이 풍부하며 운동력도 활발했지만 처리구에서는 정자량이 적고 운동력도 전자에 비하여 완만하였다. 7) 자아의 수정낭내의 정자의 상태를 관찰한바 고온구의 것은 상온구에 비하여 정자의 량과 운동이 약했으며 개체에 따라서는 발견할 수 없는 것도 있다. 8) 웅아교미기의 외부상태 및 교미기의 부속근육 등은 형태학적으로 아무런 이상이 없다. 9) 고온구의 용말기의 정소에서는 무핵정자의 상태까지 분화발달한 것이 거의 없고 대부분이 성숙분열에서 정자의 세포붕괴를 이르켜 퇴화하고 있지만 이 시기의 대조구에서는 이미 많은 무핵정자가 형성되고 있다.

  • PDF