• Title/Summary/Keyword: Motion analysis system

Search Result 2,519, Processing Time 0.04 seconds

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS (반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석)

  • Hwang, Soo-Youn;Oh, So-Ram;Lee, Yoon;Lim, Sang-Min;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 2009
  • This study aimed to assess the influence of different cross-sectional area on the cyclic fatigue fracture of Ni-Ti rotary files using a fatigue tester incorporating cyclical axial movement. Six brands of Ni-Ti rotary files (ISO 30 size with. 04 taper) of 10 each were tested: Alpha system (KOMET), HeroShaper (MicroMega), K3 (SybronEndo), Mtwo (VDW), NRT (Mani), and ProFile (Dentsply). A fatigue-tester (Denbotix) was designed to allow cyclic tension and compressive stress on the tip of the instrument. Each file was mounted on a torque controlled motor (Aseptico) using a 1:20 reduction contra-angle and was rotated at 300 rpm with a continuous, 6 mm axial oscillating motion inside an artificial steel canal. The canal had a $60^{\circ}$ angle and a 5 mm radius of curvature. Instrument fracture was visually detected and the time until fracture was recorded by a digital stop watch. The data were analyzed statistically. Fractographic analysis of all fractured surfaces was performed to determine the fracture modes using a scanning electron microscope. Cross-sectional area at 3 mm from the tip of 3 unused Ni-Ti instruments for each group was calculated using Image-Pro Plus (Imagej 1.34n, NIH). Results showed that NRT and ProFile had significantly longer time to fracture compared to the other groups (p < .05). The cross-sectional area was not significantly associated with fatigue resistance. Fractographycally, all fractured surfaces demonstrated a combination of ductile and brittle fracture. In conclusion, there was no significant relationship between fatigue resistance and the cross-sectional area of Ni-Ti instruments under experimental conditions.

Processing and Quality Control of Flux Data at Gwangneung Forest (광릉 산림의 플럭스 자료 처리와 품질 관리)

  • Lim, Hee-Jeong;Lee, Young-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.3
    • /
    • pp.82-93
    • /
    • 2008
  • In order to ensure a standardized data analysis of the eddy covariance measurements, Hong and Kim's quality control program has been updated and used to process eddy covariance data measured at two levels on the main flux tower at Gwangneung site from January to May in 2005. The updated program was allowed to remove outliers automatically for $CO_2$ and latent heat fluxes. The flag system consists of four quality groups(G, D, B and M). During the study period, the missing data were about 25% of the total records. About 60% of the good quality data were obtained after the quality control. The number of record in G group was larger at 40m than at 20m. It is due that the level of 20m was within the roughness sublayer where the presence of the canopy influences directly on the character of the turbulence. About 60% of the bad data were due to low wind speed. Energy balance closure at this site was about 40% during the study period. Large imbalance is attributed partly to the combined effects of the neglected heat storage terms, inaccuracy of ground heat flux and advection due to local wind system near the surface. The analysis of wind direction indicates that the frequent occurrence of positive momentum flux was closely associated with mountain valley wind system at this site. The negative $CO_2$ flux at night was examined in terms of averaging time. The results show that when averaging time is larger than 10min, the magnitude of calculated $CO_2$ fluxes increases rapidly, suggesting that the 30min $CO_2$ flux is influenced severely by the mesoscale motion or nonstationarity. A proper choice of averaging time needs to be considered to get accurate turbulent fluxes during nighttime.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times (호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Woong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • The gated RapidArc may produce a dosimetric error due to the stop-and-go motion of heavy gantry which can misalign the gantry restart position and reduce the accuracy of important factors in RapidArc delivery such as MLC movement and gantry speed. In this study, the effect of stop-and-go motion in gated RapidArc was analyzed with varying gating window time, which determines the total number of stop-and-go motions. Total 10 RapidArc plans for treatment of liver cancer were prepared. The RPM gating system and the moving phantom were used to set up the accurate gating window time. Two different delivery quality assurance (DQA) plans were created for each RapidArc plan. One is the portal dosimetry plan and the other is MapCHECK2 plan. The respiratory cycle was set to 4 sec and DQA plans were delivered with three different gating conditions: no gating, 1-sec gating window, and 2-sec gating window. The error between calculated dose and measured dose was evaluated based on the pass rate calculated using the gamma evaluation method with 3%/3 mm criteria. The average pass rates in the portal dosimetry plans were $98.72{\pm}0.82%$, $94.91{\pm}1.64%$, and $98.23{\pm}0.97%$ for no gating, 1-sec gating, and 2-sec gating, respectively. The average pass rates in MapCHECK2 plans were $97.80{\pm}0.91%$, $95.38{\pm}1.31%$, and $97.50{\pm}0.96%$ for no gating, 1-sec gating, and 2-sec gating, respectively. We verified that the dosimetric accuracy of gated RapidArc increases as gating window time increases and efforts should be made to increase gating window time during the RapidArc treatment process.

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

Evaluation of Intralimb Coordination in Transfemoral Amputee during Level Walking (대퇴절단인의 보행 시 하지 내 협응성 평가)

  • Chang, Yoon-hee;Jeong, Bo-ra;Kang, Sung-jae;Ryu, Jei-cheong;Mun, Mu-seong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 2016
  • The aims of this study were to evaluate the joint coordination between hip and knee joints in the transfemoral amputees, and its symmetry between sound and prosthetic limbs. Seven transfemoral amputees ($46.4{\pm}10.7-year-old$, $174.8{\pm}3.5cm$, $78.3{\pm}9.7kg$) and 7 able bodies ($24.0{\pm}4.5-year-old$, $174.5{\pm}5.9cm$, $66.9{\pm}9.4Kg$) participated in this study. They walked at a self-selected walking speed across a 10m level ground. Simultaneously angle and angular velocity in the hip and knee joint were measured by motion analysis system. Then continuos relative phase(CRP), standard deviations of CRP (CRP_SD) and symmetry index(SI) were calculated. In able bodies, there were no differences of the parameters between left and right limb(all p>0.05). However, significant differences between sound and prosthetic limb in most of the parameters, except for CRP for stance phase were shown (all p<0.05). There were differences in all SI between transfemoral amputees and able bodies (p<0.05). In conclusion, joint coordination was altered in transfemoral amputee during level walking and shown in interlimb asymmetry.

Motor Control IP Design and Quality Evaluation from the Viewpoint of Reuse (ICCAS 2004)

  • Lee, Sang-Deok;Han, Sung-Ho;Kim, Min-Soo;Park, Young-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.981-985
    • /
    • 2004
  • In this paper we designed the motor control IP Core and evaluate its quality from the viewpoint of IP reuse. The most attractive merit of this methodology, so called IP-based hardware design, is hardware reuse. Although various vendors designed hardware with the same specification and got the same functional results, all that IPs is not the same quality in the reuse aspect. As tremendous calls for SoC have been increased, associated research about IP quality standard, VSIA(Virtual Socket Interface Alliance) and STARC(Semiconductor Technology Academic Research Center), has been doing best to make the IP quality evaluation system. And they made what conforms to objective IP design standard. We suggest the methodology to evaluate our own designed motor control IP quality with this standard. To attain our goal, we designed motor control IP that could control the motor velocity and position with feedback compensation algorithm. This controller has some IP blocks : digital filter, quadrature decoder, position counter, motion compensator, and PWM generator. Each block's functionality was verified by simulator ModelSim and then its quality was evaluated. To evaluate the core, We use Vnavigator for lint test and ModelSim for coverage check. During lint process, We adapted the OpenMORE's rule based on RMM (Reuse Methodology Manual) and it could tell us our IP's quality in a manner of the scored value form. If it is high, its quality is also high, and vice versa. During coverage check ModelSim-SE is used for verifying how our test circuits cover designs. This objective methods using well-defined commercial coverage metrics could perform a quantitative analysis of simulation completeness. In this manner, We evaluated the designed motor control IP's quality from the viewpoint of reuse. This methodology will save the time and cost in designing SoC that should integrate various IPs. In addition to this, It can be the guide for comparing the equally specified IP's quality. After all, we are continuously looking forward to enhancing our motor control IP in the aspect of not only functional perfection but also IP reuse to prepare for the SoC-Compliant motor control IP design.

  • PDF

Effects of Smart Phone Use on the Gait Parameters When Healthy Young Subjects Negotiated an Obstacle (스마트폰 사용이 정상인의 장애물 보행에 미치는 영향)

  • Kim, Chang-Yong;Jeong, Hye-Won;Kim, Hyeong-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.471-479
    • /
    • 2015
  • This study examined the effects of smart phone use while young adults negotiated an obstacle (2 cm high). Seventy-four young adults (mean age: $23.76{\pm}3.17years$, age range: 20-27 years) participated in the study. They were allocated randomly into two groups; smart phone group and no smart phone group. The smart phone group negotiated an obstacle while simultaneously using a smart phone at a self-paced speed whereas the no smart phone group negotiated an obstacle with no special option. A motion analysis system were used to measure the gait parameters, such as toe clearance, cadence, step length, step width, stride length, and walking velocity in two groups. The toe clearance, and step-width, cadence, and step-length were significantly greater for the smart phone group than the no smart phone group (p<.05) and the walking velocity was significantly lower in the smart phone group (p<.05). On the other hand, there was no significant difference in the stride length between the two groups. This study suggests that smart phone use degrades the obstacle avoidance abilities of healthy young adults, which may increase risk of falls.

Analysis of Users' Emotions on Lighting Effect of Artificial Intelligence Devices (인공지능 디바이스의 조명효과에 대한 사용자의 감정 평가 분석)

  • Hyeon, Yuna;Pan, Young-hwan;Yoo, Hoon-Sik
    • Science of Emotion and Sensibility
    • /
    • v.22 no.3
    • /
    • pp.35-46
    • /
    • 2019
  • Artificial intelligence (AI) technology has been evolving to recognize and learn the languages, voice tones, and facial expressions of users so that they can respond to users' emotions in various contexts. Many AI-based services of particular importance in communications with users provide emotional interaction. However, research on nonverbal interaction as a means of expressing emotion in the AI system is still insufficient. We studied the effect of lighting on users' emotional interaction with an AI device, focusing on color and flickering motion. The AI device used in this study expresses emotions with six colors of light (red, yellow, green, blue, purple, and white) and with a three-level flickering effect (high, middle, and low velocity). We studied the responses of 50 men and women in their 20s and 30s to the emotions expressed by the light colors and flickering effects of the AI device. We found that each light color represented an emotion that was largely similar to the user's emotional image shown in a previous color-sensibility study. The rate of flickering of the lights produced changes in emotional arousal and balance. The change in arousal patterns produced similar intensities of all colors. On the other hand, changes in balance patterns were somewhat related to the emotional image in the previous color-sensibility study, but the colors were different. As AI systems and devices are becoming more diverse, our findings are expected to contribute to designing the users emotional with AI devices through lighting.