• Title/Summary/Keyword: Motion Comparison

Search Result 1,227, Processing Time 0.034 seconds

The Added Mass and Damping for the Axial Rigid Body Motion of a Marine Propeller Rotating in a Uniform Flow (선박용 프로펠러의 종방향 강체운동에 대한 부가질량)

  • Kim, Young-Joong;Lee, Hyun-Yup;Lee, Chang-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.3
    • /
    • pp.309-314
    • /
    • 2008
  • An experimental method to estimate the added mass of a marine propeller has been developed for the axial rigid body motion in still water, and the experiments have been carried out. The experimental result has been compared to the theoretical result by PRODAS based on the unsteady lifting surface theory. The experimental method developed in this research and the theoretical method by PRODAS have been validated by confirming good agreements between the experimental results and the theoretical ones. Also the comparison to the results by empirical formula has been made and discussed.

Bedload Sediment Transport and Morphological Change in Cross Sections of Straight Open-Channel (직선 개수로 횡단면에서의 소류사 이송과 지형 변화)

  • Pham, Chien Van;Kim, Tae-Boem;Choi, Sung-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.62-66
    • /
    • 2010
  • This study presents velocities of bedload sediment transport in both longitudinal and lateral directions and applied in considering morphological change of straight open channel. The velocities of particle motion have obtained by considering the forces balance acting on particles on the bed between the drag, tangential component of the immersed weight of the particle, and Coulomb's resistive forces. Numerical profiles of particle motion velocities reveals good agreement in comparison between this study and Kovacs and Parker (1994). The evaluated velocities components of particle transport are get used to estimate bedload transport rate in considering morphological change of straight open channel. For the application, numerical solution is applied to laboratory experiment which shows very close solution profiles between this study and observed data of a self-formed straight channel.

  • PDF

The Development of Skateboard for Motion capture (모션 캡쳐를 활용한 스케이트보드 개발)

  • Choi J.H.;Yoo B.C.;Lee K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.1029-1032
    • /
    • 2005
  • This paper represents a study on the development of the conceptual design for the Skateboard by TRIZ. At first the problems of the Skateboard of the commercial Skateboard was analyzed. And its development object was defined in connection with the Improvement direction. The developed conceptual design was compared with the registered patents and practical new devices at the Korea Industrial Property Office. The Comparison shows the developed conceptual design is on the same level with the above mentioned, and the usefulness of TRIZ methodology. The Analysis with the Motion Capture equipment shows the developed Skateboard commercial efficient than commercial one.

  • PDF

An Introduction of Myo Armband and Its Comparison with Motion Capture Systems

  • Cho, Junghun;Lee, Jang Hyung;Kim, Kwang Gi
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.115-120
    • /
    • 2018
  • Recently, ways for accurately measuring the three dimensional movements of hand are actively researched so as to utilize the measurement data for therapeutic and rehabilitation programs. This research paper aims to introduce a product called Myo Armband, a wearable device comprised of a 3-axis accelerometer, a 3 axis gyroscope, and electromyographic sensors. We compare Armband's performance with that of the Motion Capture System, which is known as a device for providing fairly accurate measurements for angular movements of objects. Dart throwing and wrist winding motions comprised movement scenarios. This paper also discusses one of Armband's advantages - portability, and suggests its potential as a substitute for previously used devices. Decent levels of measurement accuracy were obtained which were comparable to that of three dimensional measurement device.

Experimental Analysis on the Motion Response of a Container Ship in Irregular Head Waves (콘테이너선의 불규칙파 중 운동응답에 대한 실험적 고찰)

  • S.Y.,Hong;S.M.,Lee;D.C.,Hong
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.24 no.2
    • /
    • pp.36-46
    • /
    • 1987
  • This paper presents the results of seakeeping tests in a container ship model in irregular head waves. A time domain signal generating procedure is devised so that the wave maker behaves in accordance with the specified wave spectrum. The surface elevation of generated waves is measured and analysed to render the recorded wave spectrum for comparison with the specified one. Correction is made to the time domain signal until the differences between the two spectra become negligible. The motion responses and vertical acceleration of the self-propelled ship model are measured and analysed by both the spectral and the double amplitude methods. The two methods give nearly same statistical values. Finally the recorded spectra are compared with those calculated from the frequency domain motion analysis to show the credibility of the experimental results.

  • PDF

Effect of Hyperbaric Oxygen Therapy on the Pain, Range of Motion and Muscle Fatigue Recovery of Delayed Onset Muscle Soreness (고압산소치료가 지연성근육통의 통증, 관절운동범위 및 근피로 회복에 미치는 영향)

  • Kim, Deok Jo;Choi, Won Jye;Son, Kyung Hyun
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.2
    • /
    • pp.51-60
    • /
    • 2019
  • Background: The purpose of this study was to investigate the effects of HBOT (hyperbaric oxygen therapy) on the pain, ROM (range of motion) and muscle fatigue recovery of DOMS (delayed onset muscle soreness). Design: Randomized Controlled Trial. Methods: Twenty-six subjects who are student in their 20s at a university participated in this study, these subjects were assigned into two groups, a control group (n=12) and an experiment group (n=14). The subjects in experimental group were intervened by HBOT (40 minutes, 1.3 ATA), while ones on control group weren't by any intervention after induced DOMS. Results: First, in the comparison of VAS (visual analog scale), there were significant variations with the period (p<0.001), interaction of period (p<0.05) and group (p<0.05). In the comparison of PPT (pressure pain threshold), there were significant variations with the period (p<0.001) and interaction of period (p<0.05). Second, in the comparison of ROM, there were significant variations with the period (p<0.001), interaction of period (p<0.001) and group (p<0.01). Third, in the comparison of CK (creatine kinase) and LDH (lactate dehydrogenase), there no signigicant variations with all measure variables. Conclusion: The above results indicated that HBOT were effective to decrease the pain and improve the ROM in DOMS. Also the statistical significant variations of blood factors of muscle fatigue were not found in this.

Spatial-Temporal Scale-Invariant Human Action Recognition using Motion Gradient Histogram (모션 그래디언트 히스토그램 기반의 시공간 크기 변화에 강인한 동작 인식)

  • Kim, Kwang-Soo;Kim, Tae-Hyoung;Kwak, Soo-Yeong;Byun, Hye-Ran
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.12
    • /
    • pp.1075-1082
    • /
    • 2007
  • In this paper, we propose the method of multiple human action recognition on video clip. For being invariant to the change of speed or size of actions, Spatial-Temporal Pyramid method is applied. Proposed method can minimize the complexity of the procedures owing to select Motion Gradient Histogram (MGH) based on statistical approach for action representation feature. For multiple action detection, Motion Energy Image (MEI) of binary frame difference accumulations is adapted and then we detect each action of which area is represented by MGH. The action MGH should be compared with pre-learning MGH having pyramid method. As a result, recognition can be done by the analyze between action MGH and pre-learning MGH. Ten video clips are used for evaluating the proposed method. We have various experiments such as mono action, multiple action, speed and site scale-changes, comparison with previous method. As a result, we can see that proposed method is simple and efficient to recognize multiple human action with stale variations.

Displacements, damage measures and response spectra obtained from a synthetic accelerogram processed by causal and acausal Butterworth filters

  • Gundes Bakir, Pelin;Richard, J. Vaccaro
    • Structural Engineering and Mechanics
    • /
    • v.23 no.4
    • /
    • pp.409-430
    • /
    • 2006
  • The aim of this study is to investigate the reliability of strong motion records processed by causal and acausal Butterworth filters in comparison to the results obtained from a synthetic accelerogram. For this purpose, the fault parallel component of the Bolu record of the Duzce earthquake is modeled with a sum of exponentially damped sinusoidal components. Noise-free velocities and displacements are then obtained by analytically integrating the synthetic acceleration model. The analytical velocity and displacement signals are used as a standard with which to judge the validity of the signals obtained by filtering with causal and acausal filters and numerically integrating the acceleration model. The results show that the acausal filters are clearly preferable to the causal filters due to the fact that the response spectra obtained from the acausal filters match the spectra obtained from the simulated accelerogram better than that obtained by causal filters. The response spectra are independent from the order of the filters and from the method of integration (whether analytical integration after a spline fit to the synthetic accelerogram or the trapezoidal rule). The response spectra are sensitive to the chosen corner frequency of both the causal and the acausal filters and also to the inclusion of the pads. Accurate prediction of the static residual displacement (SRD) is very important for structures traversing faults in the near-fault regions. The greatest adverse effect of the high pass filters is their removal of the SRD. However, the noise-free displacements obtained by double integrating the synthetic accelerogram analytically preserve the SRD. It is thus apparent that conventional high pass filters should not be used for processing near-fault strong-motion records although they can be reliably used for far-fault records if applied acausally. The ground motion parameters such as ARIAS intensity, HUSID plots, Housner spectral intensity and the duration of strong-motion are found to be insensitive to the causality of filters.

Response of a frame structure on a canyon site to spatially varying ground motions

  • Bi, Kaiming;Hao, Hong;Ren, Weixin
    • Structural Engineering and Mechanics
    • /
    • v.36 no.1
    • /
    • pp.111-127
    • /
    • 2010
  • This paper studies the effects of spatially varying ground motions on the responses of a bridge frame located on a canyon site. Compared to the spatial ground motions on a uniform flat site, which is the usual assumptions in the analysis of spatial ground motion variation effects on structures, the spatial ground motions at different locations on surface of a canyon site have different intensities owing to local site amplifications, besides the loss of coherency and phase difference. In the proposed approach, the spatial ground motions are modelled in two steps. Firstly, the base rock motions are assumed to have the same intensity and are modelled with a filtered Tajimi-Kanai power spectral density function and an empirical spatial ground motion coherency loss function. Then, power spectral density function of ground motion on surface of the canyon site is derived by considering the site amplification effect based on the one dimensional seismic wave propagation theory. Dynamic, quasi-static and total responses of the model structure to various cases of spatially varying ground motions are estimated. For comparison, responses to uniform ground motion, to spatial ground motions without considering local site effects, to spatial ground motions without considering coherency loss or phase shift are also calculated. Discussions on the ground motion spatial variation and local soil site amplification effects on structural responses are made. In particular, the effects of neglecting the site amplifications in the analysis as adopted in most studies of spatial ground motion effect on structural responses are highlighted.

Localization using Ego Motion based on Fisheye Warping Image (어안 워핑 이미지 기반의 Ego motion을 이용한 위치 인식 알고리즘)

  • Choi, Yun Won;Choi, Kyung Sik;Choi, Jeong Won;Lee, Suk Gyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.70-77
    • /
    • 2014
  • This paper proposes a novel localization algorithm based on ego-motion which used Lucas-Kanade Optical Flow and warping image obtained through fish-eye lenses mounted on the robots. The omnidirectional image sensor is a desirable sensor for real-time view-based recognition of a robot because the all information around the robot can be obtained simultaneously. The preprocessing (distortion correction, image merge, etc.) of the omnidirectional image which obtained by camera using reflect in mirror or by connection of multiple camera images is essential because it is difficult to obtain information from the original image. The core of the proposed algorithm may be summarized as follows: First, we capture instantaneous $360^{\circ}$ panoramic images around a robot through fish-eye lenses which are mounted in the bottom direction. Second, we extract motion vectors using Lucas-Kanade Optical Flow in preprocessed image. Third, we estimate the robot position and angle using ego-motion method which used direction of vector and vanishing point obtained by RANSAC. We confirmed the reliability of localization algorithm using ego-motion based on fisheye warping image through comparison between results (position and angle) of the experiment obtained using the proposed algorithm and results of the experiment measured from Global Vision Localization System.