• Title/Summary/Keyword: Motion Analyzer

Search Result 84, Processing Time 0.022 seconds

Effect of Elastic Aids (Bands) on Functional Reach Test in Patients with Spinal Cord Injury: Pilot Study

  • Jong Ho Kang;Tae Sung Park
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.317-320
    • /
    • 2022
  • Purpose: This study aimed: to confirm the balance ability of patients with spinal cord injury in the sitting state through a functional reach test using an elastic aid; and to propose a balance improvement plan. Methods: The study evaluated seven patients with spinal cord injury who could maintain a sitting posture through minimum assistance. A functional reach test was performed before and after wearing an elastic aid while sitting on a chair, and the effects before and after use of the elastic aid were compared and analyzed through a motion analyzer. Results: In the functional reach test, the forward movement distance of the hand was 97.45 mm before wearing the elastic aid, but significantly increased to 131 mm after wearing the aid (p<0.05). Corresponding forward movement distances for the shoulder were 81.26 mm and 113 mm (p<0.05 for the increase). There was no statistically significant change in lateral functional arm extension. Conclusion: It was confirmed, through a functional reach test, that trunk stability in patients with spinal cord injury increased with use of an elastic aid. In future, more efficient rehabilitation treatment programs will be possible if trunk stability in patients with spinal cord injury is improved by using elastic aids, and if various exercise treatments are also included in the rehabilitation programs.

An Experimental Study for the Design of Household-Storage Facilities (부엌 수납장 설계 기준 설정을 위한 기초적 연구)

  • 최재순
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.4
    • /
    • pp.155-168
    • /
    • 1982
  • What is attempted here is to find out an optimum method for the design of physical environments that could save human energy expenditures and safely perform household duties. There are, if any, very little amount of research done in this area. This is particulary so when the work relates to the designing of household storage facilities in the light of the energy metabolism of human body. The first step to this study, therefore, is to find out the ways by which we can determine the energy metabolism of human body accurately. To measure the volume and the concentration of human respiration continuously and automatically, a new apparatus is selected here. This includes the recording system with the Wright Respirometer and the Expired Gas Analyzer as well as the computer system to multiply volume by concentration of human respiration and to integrate them for a given time. Then, the author experimented on the reliability of this apparatus and came to the conclusion that this apparatus satisfied our need to research the energy metabolism of human body. Next, the general plan and procedures to experiment with this apparatus have been determined as follows: 1) subjects are three young and sound females. Their physical characteristics are shown in Table 1 and most approximates the standard characteristics of Japanese females, 2) height of open shelves is selected in such away as to correspond to the respective height of each subject(see Table 2), 3) utensils to be stored are box shaped object, which weight is 0.5kg, 1.0kg, 2.0kg or 3.0kg, 4) working motions are given while one or two hands as to place utensil on each shelf from the standard working board, 85 cm in height and then to place back it on the board from the shelf and repeated in constant velocity as 10 times per a minute, 5) each posture of motion is chosen by each subject in free, 6) procedures of measurement of human energy metabolism ard shown at(6), 1, Section 3 as specific methods for using this apparatus. Findings of this study are as follows: 1. Human energy expenditures for storing utensils on shelves by each subject are shown in quantity more accurately than in any other studies, under varying conditions about height of shelves, load of utensils and working motion with one hand and two hands (see Fig. 8~13 and Table 3). 2. Experimental formulae of human energy expenditure for that work are shown as formula (8), (9) and (10), to generalize results of 1. and to apply those for working motion under given conditions. 3. As results of analysis on gained data, we are able to show the standard model of human energy expenditures for storing untensils on shelves by the standard Japanese female (see Table 7 and Fig. 14).

  • PDF

Objective Identification of Human Sperm Hyperactivation by Computerized Sperm Motion Analysis (Computerized Sperm Motility Analyzer를 이용한 Human Sperm의 Hyperactivated Motility의 객관적 관찰에 관한 연구)

  • Lee, Hee-Kyung;Lee, Chan;Kim, Hyun-Sook;Kim, Young-Tae;Kim, Sun-Haeng;Ku, Pyoung-Sahm
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1994
  • The occurrence and time course of capacitation, acrosomal loss, and hyperactivated motility require quantitative definition in order to characterize fertile human sperm. Recently the method has been developed to estimate the quality of spermatozoa by using kinematic parameters such as curvilinear velocity(VCL), average path velocity(VAP), linearity(LIN), straightness(STR), amplitude of lateral head displacement(ALH), and beat cross frequence(BCF) from Computer Assisted Sperm Analysis (CASA). In this study, using the Hamilton Thorn motility analyzer HTM 2030(Hamilton Thorn Research, Beverly, MA), we attempted to identify the spermatozoa with hyperactivated motility (HA) objectively and to monitor hyperactivation of human spermatozoa during incubation in capacitating media and after treatment of calcium ionophore as compared with acrosome status. And we examined whether HA are related to the result of SPA. Semen samples obtained from 16 healthy men were prepared by swim up technique and preincubated in a capacitating media(modified BWW medium) for 5 hours and treated with calcium ionophore solution. The acrosome reaction was detected with PSA-FITC labelling of the acrosome and in vitro sperm ferilizing capacity was assessed by the zona free hamster ovum penetration assay (SPA). The incidence of hyperactivated sperm was 2.6% in fresh semen, 14.3% of the swim up population, 13.7% after 5h of incubation. Significant increase of percentage of hyperactivated sperm was observed after the incubation (p<0.05) but after treatment, no significant changes of percentage of hyperactivated sperm(l1.8%) in contrast to significant rise in the percentage of acrosome reacted cells. Correlation analysis failed to show any significant relationship between the percentage of sperm with HA and SPA score. In conclusion, although no direct correlations were found between the results of SPA and HA, hyperactivation of sperm is associated with capacitation and monitoring hyperactivated sperm will be expected as a method of evaluating the functional quality of sperm such as SPA.

  • PDF

The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT (체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Lee, Jeong-woo;Shin, Young-Joo;Kang, Dong-Jin;Jung, Jae-Yong
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

The Effects of Game-Based Weight Bearing Balance Training on Phase Sit to Stand to Sit and Functional Standing Performance Stroke Patients (게임기반 체중지지 균형훈련이 뇌졸중 환자의 단계별 일어서고 앉기 동작과 기능적 일어서기 수행력에 미치는 효과)

  • Yang, Daejung;Uhm, Yohan
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.4
    • /
    • pp.21-30
    • /
    • 2017
  • Purpose : This research intends to identify the effects of game-based weight bearing exercises on balance, muscular activation, sit to stand to sit motions of stroke patients. Method : 30 patients who were diagnosed as hemiplegia by stroke less in than a year were sampled and they were classified into two group, one of which was game-based weight bearing balance exercise group, and the other was functional weight bearing exercise group. 15 people were randomly selected for each group. Each exercise was coordinated by this research for 8 weeks, 5 days a week. 3D motion analyzer was used to measure the sit to stand to sit motions and a stopwatch was used to measure the time for stand-up motions for 5 times. Result : In terms of analyzing sit to stand to sit motions by phases, game-based weight bearing balance exercise group showed significant reduction compared to functional weight-bearing exercise group in phase I, II, III, IV and total time. In terms of functional stand-up performance analysis, game-based weight bearing balance exercise group showed significant reduction compared to functional weight-bearing exercise group in 5 times stand-up examination. Conclusion : It was verified that game-based weight bearing balance exercise had positive impact on function recovery of stroke patients by enhancing sit to stand to sit capabilities. It is considered that game-based exercise was an effective intermediary for functional improvement of stroke patients, while also inducing consistent and voluntary participation by causing interest and motivation.

Measurements of Radial In-plane Vibration Characteristics of Piezoelectric Disk Transducers (원판형 압전 변환기의 면내 방사 진동 특성 측정)

  • Kim, Dae Jong;Oh, Se Hwan;Kim, Jin Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.13-23
    • /
    • 2015
  • The paper experimentally deals with the radial in-plane vibration characteristics of disk-shaped piezoelectric transducers. The radial in-plane motion, which is induced due to Poisson's ratio in the piezoelectric disk polarized in the thickness direction, was measured by using an in-plane laser vibrometer, and the natural frequencies were measured by using an impedance analyzer. The experimental results have been compared with theoretical predictions obtained by simplified theoretical and finite-element analyses. It appears that the fundamental mode of a piezoelectric disk transducer is a radial mode and its radial displacement distribution from the center to the perimeter is not monotonic but shows maximum slightly apart from the perimeter. The theoretically-calculated fundamental frequencies agree well with the finite-element results for small thickness-to-diameter ratio, and they are accurate within 7 % error for the ratio up to 0.4.

A Study on Design and Manufacture of an Inchworm Linear Motor System (인치웜 리니어 모터 시스템 설계 및 제작에 관한 연구)

  • Ye Sang Don;Jeong Jae Hoon;Min Byeong Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.174-181
    • /
    • 2004
  • Ultra precision positioning mechanism has widely been used on semiconductor manufacturing equipments, optical spectrum analyzer and cell manipulations. Ultra precision positioning mechanism is consisted of several actuators, sensors, guides and control systems. Its efficiency depends on each performance of components. The object of this study is to design, analysis and manufacture all of the inchworm linear motor system, which is one of the equipments embodied in ultra precision positioning mechanism. Inchworm linear motor system is consisted of a controller system and an inchworm linear motor, and its driving form is similar to a motion of spanworm. A design and manufacture of inchworm linear motor, which is consisted of three PZT actuators, a rod, two columns and a guide plate, are performed. Minimizing the von-Mises stress of the hinge using Taguchi method and simulation by FEM software optimizes the structural design in a column of flexure hinge. The designed columns and guide plates are manufactured by a W-EDM and NC-milling. A controller system, which is an apparatus to drive inchworm linear motor, can easily adjust driving conditions by varying resonance frequency and input-output voltage of actuators and amplifiers. The performance of manufactured inchworm linear motor system is verified and valuated. In the future, inchworm linear motor system will be used to make a more precision positioning by reinforcing a sensor and feedback system.

Effect of Cholesterol-loaded-cyclodextrin in Presence and Absence of Egg Yolk during Freezing Step on Quality of Markhoz Buck's Spermatozoa

  • Farshad, A.;Amidi, F.;Khor, A. Koohi;Rashidi, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.2
    • /
    • pp.181-189
    • /
    • 2011
  • Cryopreservation protocols induce partially irreversible damage to mammalian sperm plasma membranes. Previous studies have indicated that adding cholesterol to the plasma membrane, as cholesterol-loaded-cyclodextrins, improves cryosurvival of sperm. Therefore, the purpose of this study was to determine if treating sperm of Markhoz bucks with cholesterol-loaded-cyclodextrins (CLC) (0, 0.75, 1.5, 2.25 and 3 mg/ml diluted $240{\times}10^6$ sperm/ml) in Tris-citric acid-glucose diluents with and without egg yolk (containing 5% glycerol) would improve the post-thaw sperm quality. The motion characteristics were evaluated with a Computer Assisted System Analyzer (CASA); acrosome integrity and vitality were measured with the triple-stain technique. Samples were recovered before and after freezing by means of putting straws into $37^{\circ}C$ water for 30 sec and then parameters were assessed. The results showed that the treatments significantly affected motility, progressive motility, recovery rate, curvilinear velocity, beat cross frequency, live sperm with reacted acrosome, live sperm with unreacted acrosome, dead sperm with reacted acrosorne, and dead sperm with unreacted acrosome during freezing (p<0.05). However; no significant differences were found for average path velocity, straight line velocity, amplitude of lateral head displacement, straightness and linearity (p>0.05). The best results were observed for extender containing 2.25 mg/ml ($240{\times}10^6$ sperm/ml) CLC supplemented with 2.6% egg yolk. In conclusion, the findings of this study indicate improved Markhoz sperm viability and motility following treatment in the presence of egg yolk.

The Exoscope versus operating microscope in microvascular surgery: A simulation non-inferiority trial

  • Pafitanis, Georgios;Hadjiandreou, Michalis;Alamri, Alexander;Uff, Christopher;Walsh, Daniel;Myers, Simon
    • Archives of Plastic Surgery
    • /
    • v.47 no.3
    • /
    • pp.242-249
    • /
    • 2020
  • Background The Exoscope is a novel high-definition digital camera system. There is limited evidence signifying the use of exoscopic devices in microsurgery. This trial objectively assesses the effects of the use of the Exoscope as an alternative to the standard operating microscope (OM) on the performance of experts in a simulated microvascular anastomosis. Methods Modus V Exoscope and OM were used by expert microsurgeons to perform standardized tasks. Hand-motion analyzer measured the total pathlength (TP), total movements (TM), total time (TT), and quality of end-product anastomosis. A clinical margin of TT was performed to prove non-inferiority. An expert performed consecutive microvascular anastomoses to provide the exoscopic learning curve until reached plateau in TT. Results Ten micro sutures and 10 anastomoses were performed. Analysis demonstrated statistically significant differences in performing micro sutures for TP, TM, and TT. There was statistical significance in TM and TT, however, marginal non-significant difference in TP regarding microvascular anastomoses performance. The intimal suture line analysis demonstrated no statistically significant differences. Non-inferiority results based on clinical inferiority margin (Δ) of TT=10 minutes demonstrated an absolute difference of 0.07 minutes between OM and Exoscope cohorts. A 51%, 58%, and 46% improvement or reduction was achieved in TT, TM, TP, respectively, during the exoscopic microvascular anastomosis learning curve. Conclusions This study demonstrated that experts' Exoscope anastomoses appear non-inferior to the OM anastomoses. Exoscopic microvascular anastomosis was more time consuming but end-product (patency) in not clinically inferior. Experts' "warm-up" learning curve is steep but swift and may prove to reach clinical equality.

Analysis of Ground Reaction Force by Stance Type during Tennis Forehand Stroke (테니스 포핸드 스트로크 스탠스 유형의 지면반력 분석)

  • Kang, Yong-Teak;Seo, Kook-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.449-455
    • /
    • 2009
  • The purpose of this study was to analyze the kinetics variables of GRF by dtance type during forehand stroke. Eight high school tennis players, who have never been injured for last six months, in Busan were chosen for the study. They performed horizontal swing and vertical swing that it was done each five consecutive trial in the condition of square, semi-open and open stance. It was filmed by 6 video camera and used with 3-dimensional motion analyzer system and GRF system. The following kinetic variables were analyzed in relation to left leg and right leg GRF. The conclusion were as follow: 1. In square and semi-open stances, the horizontal ground reaction force was decreased at impact in left leg regardless of swing type, whereas open stance was increased at impact to the tiptoe in both legs. 2. In square and semi-open stances, the vertical ground reaction force was increased at impact in left leg regardless of swing types, whereas open stance was decreased at impact to vertical direction in both legs.