• Title/Summary/Keyword: Most right digit

Search Result 5, Processing Time 0.02 seconds

Surgical Correction of Hexadactyly: Innovation of new technique and its application (여섯 손가락증의 수술적 교정: 새로운 수술 방법의 고안과 적용)

  • Tark, Kwan Chul;Lee, Myung Chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.642-648
    • /
    • 2009
  • Purpose: Hexadactyly without thumb is a rare congenital anomaly of the hand where six triphalangeal digits are symmetrically distributed without thumb. Contrary to mirror hands, triphalangeal six digits are symmetrically distributed on each side at the midline with well - differentiated carpal bones, extensor tendons, one ulnar and one radius. The authors developed a new surgical technique based on a three - dimensional concept to correct the hexadactyly and applied to 2 cases of hexadactyly with good functional and aesthetic results. Here we document the surgical technique and its result. Methods: A 16 month old male patient visited our clinic with chief complaints of bilateral hexadactyly deformity. On physical examination most radial first and second digits showed no opposition and adduction motion on both side hands. Radiography showed 6 triphalangeal digits with normal development of carpal, radial and ulnar bone. Right side abnormality was corrected by removal of most radial side extra - digit, rotation and migration of 2nd ray to thumb position and creation of 1st web by transposing a mid - palm based rectangular palmar flap as in Snow & Littler procedure which has been being applied for correction of 1st web syndactyly in cleft hand deformity. Seven months later, left side abnormality was also corrected with the same procedure. Results: Postoperative appearances of the both hands were satisfactory. Flexion, extension, opposition and grasping were possible with the pollicized 2nd ray. Pinching power was 3.0 kg 15 months after surgery and 2.5 kg 22 months after in right hand respectively. Conclusion: In correction of hexadactyly deformity, satisfactory aesthetic and relevant functional results can be expected with authors' newly developed technique: removal of most radial digit, rotation and migration of 2nd digit to thumb position as well as creation of the 1st web space by transposition of mid - palm based rectangular flap.

A Comparison Between the Korean Digits-in-Noise Test and the Korean Speech Perception-in-Noise Test in Normal-Hearing and Hearing-Impaired Listeners

  • Kim, Subin;You, Sungwha;Sohn, Myoung Eun;Han, Woojae;Seo, Jae-Hyun;Oh, Yonghee
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.171-177
    • /
    • 2021
  • Background and Objectives: The purpose of the present study was to validate the performance and diagnostic efficacy of the Korean digits-in-noise (K-DIN) test in comparison to the Korean speech perception-in-noise (K-SPIN) test, which is the representative speech-in-noise test in clinical practice. Subjects and Methods: Twenty-seven subjects (15 normal-hearing and 12 hearing-impaired listeners) participated. The recorded Korean 0-9 digits were used to form quasirandom digit triplets; 50 target digit triplets were presented at the most comfortable level of each subject while presenting speech-shaped background noise at various levels of signal-to-noise ratios (-12.5, -10, -5, or +5 dB). Subjects were then instructed to listen to both target and noise masker unilaterally and bilaterally through a headphone. K-SPIN test was also conducted using the same procedure as the K-DIN. After calculating their percent correct responses, K-DIN and K-SPIN results were compared using a Pearson-correlation test. Results: Results showed a statistically significant correlation between K-DIN and K-SPIN in all hearing conditions (left: r=0.814, p<0.001; right: r=0.788, p<0.001; bilateral: r=0.727, p<0.001). Moreover, the K-DIN test achieved better testing efficacy, shorter average listening time (5 min vs. 30 min), and easier performance of task according to participants' qualitative reports than the K-SPIN test. Conclusions: In this study, the Korean version of digit triplet test was validated in both normal-hearing and hearing-impaired listeners. The findings suggest that the K-DIN test can be used as a simple and time-efficient hearing-in-noise test in audiology clinics in Korea.

A Comparison Between the Korean Digits-in-Noise Test and the Korean Speech Perception-in-Noise Test in Normal-Hearing and Hearing-Impaired Listeners

  • Kim, Subin;You, Sungwha;Sohn, Myoung Eun;Han, Woojae;Seo, Jae-Hyun;Oh, Yonghee
    • Korean Journal of Audiology
    • /
    • v.25 no.4
    • /
    • pp.171-177
    • /
    • 2021
  • Background and Objectives: The purpose of the present study was to validate the performance and diagnostic efficacy of the Korean digits-in-noise (K-DIN) test in comparison to the Korean speech perception-in-noise (K-SPIN) test, which is the representative speech-in-noise test in clinical practice. Subjects and Methods: Twenty-seven subjects (15 normal-hearing and 12 hearing-impaired listeners) participated. The recorded Korean 0-9 digits were used to form quasirandom digit triplets; 50 target digit triplets were presented at the most comfortable level of each subject while presenting speech-shaped background noise at various levels of signal-to-noise ratios (-12.5, -10, -5, or +5 dB). Subjects were then instructed to listen to both target and noise masker unilaterally and bilaterally through a headphone. K-SPIN test was also conducted using the same procedure as the K-DIN. After calculating their percent correct responses, K-DIN and K-SPIN results were compared using a Pearson-correlation test. Results: Results showed a statistically significant correlation between K-DIN and K-SPIN in all hearing conditions (left: r=0.814, p<0.001; right: r=0.788, p<0.001; bilateral: r=0.727, p<0.001). Moreover, the K-DIN test achieved better testing efficacy, shorter average listening time (5 min vs. 30 min), and easier performance of task according to participants' qualitative reports than the K-SPIN test. Conclusions: In this study, the Korean version of digit triplet test was validated in both normal-hearing and hearing-impaired listeners. The findings suggest that the K-DIN test can be used as a simple and time-efficient hearing-in-noise test in audiology clinics in Korea.

Generalized Divisibility Rule of Natural Number m (자연수 m의 일반화된 배수 판정법)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.87-93
    • /
    • 2014
  • For n/m=qm+r, there is no simple divisibility rule for simple m=7 such that is the n multiply by m? This problem can be more complex for two or more digits of m. The Dunkels method has been known for generalized divisibility test method, but this method can not compute very large digits number that can not processed by computer. This paper suggests simple and exact divisibility method for m completely irrelevant n and m of digits. The proposed method sets $r_1=n_1n_2{\cdots}n_l(mod m)$ for $n=n_1n_2n_3{\cdots}n_k$, $m=m_1m_2{\cdots}m_l$. Then this method computes $r_i=r_{i-1}{\times}10+n_i(mod m)$, $i=2,3,{\cdots}k-l+1$ and reduces the digits of n one-by-one. The proposed method can be get the quotient and remainder with easy, fast and correct for various n,m experimental data.

Glomus Tumor in Soleus Muscle: A Case Report (가자미근에 발생한 사구종 1례)

  • Seo, Byung Chul;Oh, Deuk Young;Park, Kyeng Sin;Lee, Paik Kwon;Rhie, Jong Won;Han, Ki Taik;Ahn, Sang Tae;Kim, Tae Jung
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.518-520
    • /
    • 2006
  • Purpose: Glomus tumors are uncommon benign neoplasms arising from the neuromyoarterial apparatus, usually seen in the nail bed of fingers. Most of this mass presents typical symptoms such as severe pain, point tenderness and hypersensitivity to cold like neuroma, gout or causalgia. Concerning about the origin, there were few written reports about extra-digit glomus tumor, especially that occurred in the skeletal muscule. Methods: A 48-year-old female complained of painful tender mass in her right calf aggravated several months ago. Her MRI and femoral angiogram showed a well defined hypervascular tumor such as hemagioma or hemagioendothelioma in the right calf. Surgical treatment was performed, and it proved glomus tumor in soleus muscle histologically. Results: After the operation, patient didn't complain of her symptoms any more and there was no evidence of recurrence during 1 year follow-up period. Conclusion: Authors have found only eight cases of intramuscular glomus tumor reported in the literature and present here the ninth case of an intramuscular glomus tumor and first case of soleus muscle.