• Title/Summary/Keyword: Morphometry index

Search Result 14, Processing Time 0.048 seconds

A Comparative Study between the Accuracy of Three-Dimensional MorphometIy and That of PA CephalometIy in Asymmetry Analysis (비대칭 분석시 3차원영상의 정확성에 관한 정보 두부방사선사진과의 비교연구)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.95-106
    • /
    • 2001
  • The purpose of this study was to show the method of three-dimensional morphometry developed recently and to compare the accuracy of three-dimensional morphometry with those of PA cephalometry, The three-dimensional morphometry analysis program and device were developed. Steel balls (1.2mm in diameter) were attached in twenty five landmarks of artificial human skull. This artificial human skull was used as experimental materials. From three-dimensional morphometry and PA cephalometry of artificial human skull. eleven linear measurements were acquired and made into asymmetry index. Right-left differences of measurements were used as asymmetry index. These measurements and asymmetry index were compared respectively with those of actual. The results were as follows: 1. Mean difference between three-dimensional morphometry and actual artificial human skull in linear measurements was $1.99{\pm}0.37mm$, and mean difference between PA cephalometry and actual was $21.12{\pm}0.45mm$. Both of all were reduced more than those of actual. 2. Mean difference between three-dimensional morphometry and actual artificial human skull in asymmetry index was $0.07{\pm}0.42$, and mean difference between PA cephalometry and actual was $3.63{\pm}0.60$. Three-dimensional morphometry was reduced while PA cephalometry was magnified more than that of actual. 3. Each eleven asymmetry index of three-dimensional morphometry was the same negative sign as those of actuals while only N-Z, ANS-J, Tr-Go, Tr-ANS asymmetry index were the same in PA cephalometry. These results suggest that the method of three-dimensional morphometry is more accurate than those of PA cephalometry in asymmetry analysis.

  • PDF

BrdU에 의한 DNA

  • 손우찬;김형진;이영순
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.83-92
    • /
    • 1991
  • Complexities of testis structure and function are emphasized in morphometrical and genotoxic evaluation by statistical analysis. F-344 rats were treated with azinphos methyl, cyclophosphomide, and dichlorvos. And Brdu was injected with intrapertionially before sacrifice. The existence and degree of DNA damage were measured by Brdu labeling index which represented relative amount of Brdu incorporated in DNA, morphometric change was evaluated by the relative length of tubular diameter in circular seminiferous tubules and the number of spermatogonia per Sertoli cell in stage IX seminiferous tubules.

  • PDF

Assessing Cerebral Oxygen Metabolism Changes in Patients With Preeclampsia Using Voxel-Based Morphometry of Oxygen Extraction Fraction Maps in Magnetic Resonance Imaging

  • Qihao Zhang;Chaofan Sui;Junghun Cho;Linfeng Yang;Tao Chen;Bin Guo;Kelly McCabe Gillen;Jing Li;Lingfei Guo;Yi Wang
    • Korean Journal of Radiology
    • /
    • v.24 no.4
    • /
    • pp.324-337
    • /
    • 2023
  • Objective: The objective of this study was to analyze the different brain oxygen metabolism statuses in preeclampsia using magnetic resonance imaging and investigate the factors that affect cerebral oxygen metabolism in preeclampsia. Materials and Methods: Forty-nine women with preeclampsia (mean age 32.4 years; range, 18-44 years), 22 pregnant healthy controls (PHCs) (mean age 30.7 years; range, 23-40 years), and 40 non-pregnant healthy controls (NPHCs) (mean age 32.5 years; range, 20-42 years) were included in this study. Brain oxygen extraction fraction (OEF) values were computed using quantitative susceptibility mapping (QSM) plus quantitative blood oxygen level-dependent magnitude-based OEF mapping (QSM + quantitative blood oxygen level-dependent imaging or QQ) obtained with a 1.5-T scanner. Voxel-based morphometry (VBM) was used to investigate the differences in OEF values in the brain regions among the groups. Results: Among the three groups, the average OEF values were significantly different in multiple brain areas, including the parahippocampus, multiple gyri of the frontal lobe, calcarine, cuneus, and precuneus (all P-values were less than 0.05, after correcting for multiple comparisons). The average OEF values of the preeclampsia group were higher than those of the PHC and NPHC groups. The bilateral superior frontal gyrus/bilateral medial superior frontal gyrus had the largest size of the aforementioned brain regions, and the OEF values in this area were 24.2 ± 4.6, 21.3 ± 2.4, and 20.6 ± 2.8 in the preeclampsia, PHC, and NPHC groups, respectively. In addition, the OEF values showed no significant differences between NPHC and PHC. Correlation analysis revealed that the OEF values of some brain regions (mainly involving the frontal, occipital, and temporal gyrus) were positively correlated with age, gestational week, body mass index, and mean blood pressure in the preeclampsia group (r = 0.361-0.812). Conclusion: Using whole-brain VBM analysis, we found that patients with preeclampsia had higher OEF values than controls.

Brain Mapping Using Neuroimaging

  • Tae, Woo-Suk;Kang, Shin-Hyuk;Ham, Byung-Joo;Kim, Byung-Jo;Pyun, Sung-Bom
    • Applied Microscopy
    • /
    • v.46 no.4
    • /
    • pp.179-183
    • /
    • 2016
  • Mapping brain structural and functional connections through the whole brain is essential for understanding brain mechanisms and the physiological bases of brain diseases. Although region specific structural or functional deficits cause brain diseases, the changes of interregional connections could also be important factors of brain diseases. This review will introduce common neuroimaging modalities, including structural magnetic resonance imaging (MRI), functional MRI (fMRI), diffusion tensor imaging, and other recent neuroimaging analyses methods, such as voxel-based morphometry, cortical thickness analysis, local gyrification index, and shape analysis for structural imaging. Tract-Based Spatial Statistics, TRActs Constrained by UnderLying Anatomy for diffusion MRI, and independent component analysis for fMRI also will also be introduced.

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.

Clinical and anatomical importance of foramen magnum and craniocervical junction structures in the perspective of surgical approaches

  • Berin Tugtag Demir;Simge Esme;Dilara Patat;Burak Bilecenoglu
    • Anatomy and Cell Biology
    • /
    • v.56 no.3
    • /
    • pp.342-349
    • /
    • 2023
  • This study was conducted to investigate the clinical and anatomical importance of the relevant region from the perspective of surgical approaches by determining the morphometric analysis of the craniocervical junction and foramen magnum (FM) region and determining their distances from important anatomical points. This research was carried out with 59 skulls found at the Anatomy Laboratories of Erciyes and Ankara Medipol University. Metric measurements of FM and condyle, FM shape, condyle-fossa relationship, and pharyngeal tubercle (PT) were made in mm-based dry bone samples of unknown age and sex. The distance between the anterior notches and the FM was 87.01±4.35, the distance between the anterior notches and the PT was 77.70±4.24, the distance between the PT-sphenooccipital junction was 13.23±2.42, and the FM index was 81.86±7.47. The anteroposterior and transverse lengths of FM were determined as 33.80±2.99 and 27.72±2.30, respectively. The morphometric and morphological data available regarding the craniocervical junction showed significant differences between populations. Comprehensive knowledge of this topic will provide a better approach to treat Arnold Chiari Malformation, FM meningiomas, and other posterior cranial fossa lesions. Therefore, we believe that FM and craniocervical junction morphology will be a guide not only for anatomists, but also for radiologists, neurosurgeons, ENT surgeons, and orthopedists.

Comparison of radiographic and computed tomographic acetabular index in small-breed dogs: a preliminary study using Maltese and Shih Tzu

  • Kanthavichit, Kanokporn;Klaengkaew, Auraiwan;Thanaboonnipat, Chutimon;Darawiroj, Damri;Soontornvipart, Kumpanart;Choisunirachon, Nan
    • Journal of Veterinary Science
    • /
    • v.22 no.4
    • /
    • pp.58.1-58.13
    • /
    • 2021
  • Background: The morphometry of the acetabulum is one source of information that assists in the clinical diagnosis of the hip and influences the proper selection of a prosthesis, reducing post-operative complications such as those seen in total hip replacement (THR). However, acetabular parameters in small-breed dogs are rarely reported. Objectives: To investigate acetabular parameters using radiography and computed tomography (CT) in small-breed dogs with Maltese and Shih Tzu dogs used as model breeds. Methods: Standard calibrated, extended hip radiographs and CT images were obtained. Subsequently, acetabular width (AW) in various directions was measured using radiography and CT, whereas acetabular depth (AD) was obtained by CT. Acetabular index (AI) is a ratio calculated from AD and AW. Results: The values of AW and AD were much higher in Shih Tzu than in Maltese dogs. Male Shih Tzus showed higher values of these parameters than females, while sex-based differences in most of the parameters could not be detected in Maltese. Body weight, but not age, influenced AWs and ADs. While AWs and ADs were influenced by several factors, AI was comparable among the assessed factors and between Maltese and Shih Tzu dogs (p = 0.172; 31.42 ± 1.35 and 32.60 ± 1.80, respectively). Also, AI did not vary with breed, sex, or body size. Conclusions: The obtained radiographic and CT acetabular parameters could be useful as guidelines for evaluating the acetabulum of small-breed dogs in clinical practice.

Standard Index Development for Comparing the Glomerular Number (사구체 수의 증감을 비교할 수 잇는 기준 개발)

  • Kim, Yong-Jin;Lee, Chi-Eun;Lee, Kook-Joo;Choi, Young-Ho;Hong, Jung-Suk
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.85-93
    • /
    • 2001
  • Background: The number of glomerulus has been considered one of the etiologic factors especially for focal segmental glomerulosclerosis. However, glomeruli are too many to calculate them correctly. Although the fractionator method has became convinced, in which they used selected sections, not whole kidney sections, with same intervals, it is also very hard to get good results. Because it is still very time-consuming and laborous work which leads to make big observers' biases. Methods and Materials: We designed the index for glomerular number to estimate the tendency of increase or decrease of the number of it in different kidneys and which was evaluated by other conventional methods including fractionator method. Index was based upon the theory by Nyengaard; "the number of glomerulus correlates with the weight of kidney, which is positively correlated with body weight". Calculating formula is the number of glomeruli/surface areas of cortices, which contain calculated glomeruli multiplies by kidney weight/body weight. Results: We applied this index to kidneys of FGS/Kist mouse and those of RFM/Nga mouse. The former is spontaneous glomerulosclerosis model with heavy protein uria and renal failure and the latter is the mother side of FGS/Kist mouse but has no glomerular disease or protein uria. The number of glomerulus of FGS/Kist mouse was decreased by 30% to those of RFM/Nga mouse. Conclusion: This index was useful and reliable for estimating the relative glomerular number between two groups.

  • PDF

Comparison of Morphological Characteristics of the Subaxial Cervical Spine between Athetoid Cerebral Palsy and Normal Control

  • Kim, Jun Young;Kwon, Jae Yeol;Kim, Moon Seok;Lee, Jeong Jae;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.243-250
    • /
    • 2018
  • Objective : To compare the morphometry of subaxial cervical spine between cerebral palsy (CP) and normal control. Methods : We retrospectively analyzed 72 patients with CP, as well as 72 patients from normal population. The two groups were matched for age, sex, and body mass index. Pedicle, lateral mass (LM), and vertebral foramen were evaluated using computed tomography (CT) imaging. Pedicle diameter, LM height, thickness, width and vertebral foramen asymmetry (VFA) were measured and compared between the two groups. Cervical dynamic motion, disc and facet joint degeneration were investigated. Additionally, we compared the morphology of LM between convex side and concave side with cervical scoliotic CP patients. Results : LM height was smaller in CP group. LM thickness and width were larger in CP group at mid-cervical level. In 40 CP patients with cervical scoliosis, there were no height and width differences between convex and concave side. Pedicle outer diameter was not statistically different between two groups. Pedicle inner diameter was significantly smaller in CP group. Pedicle sclerosis was more frequent in CP patients. VFA was larger in CP group at C3, C4, and C5. Disc/facet degeneration grade was higher in the CP group. Cervical motion of CP group was smaller than those of the control group. Conclusion : LM morphology of CP patients was different from normal population. Sclerotic pedicles and vertebral foramen asymmetry were more commonly identified in CP patients. CP patients were more likely to demonstrate progressive disc/facet degeneration. This data may provide useful information on cervical posterior instrumentation in CP patients.