• Title/Summary/Keyword: Monitoring equipment

Search Result 1,088, Processing Time 0.025 seconds

A Study on the Diagnosis system for the propulsion equipment in railway rolling stock (철도차량용 전기추진장치의 진단시스템 연구)

  • Park, Hyun-June;Kim, Gil-Dong;Byun, Yoon-Sub;Han, Young-Jae;Jang, Dong-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1245-1247
    • /
    • 2001
  • This paper discusses that the maintenance of the propulsion equipment in railway rolling stock. Condition monitoring of railway equipment is the need for integration of remote condition monitoring with maintenance management strategies. The paper outlines research leading to the design and development of a prototype control and monitoring system for propulsion equipment.

  • PDF

Development of firing equipment and monitoring system for electric power conversion system for high voltage and large current (고압 대전류용 전력변환 점호장치 및 감시시스템 개발)

  • Lee Joo-Hyun;Lim Ick-Hun;Ryu Ho-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.481-484
    • /
    • 2006
  • A electric power conversion system in a pumped storage power plant is important equipment for converting electric motor kinetic energy into electric power. A electric power conversion monitoring system consists of high voltage thyristor firing equipment, fault detection module, data gathering module, real time data processing equipment and man machine interface system. This paper describes electric power conversion system overview, the developed SFC monitoring system configuration including system characteristics, and successful application result to San-Cheong pumped storage power plant.

  • PDF

Implementation of Status Monitoring System based on RFID in Electric Power Equipment (발전설비장치에서 RFID기반 상태관리시스템 구현)

  • Han, Gun-Hee;Hong, Jin-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2379-2383
    • /
    • 2009
  • In this paper, it is reviewed implementation of information system base on RFID for management of power equipment, and the managed status items are input/out of resource, purchasing and ordering, drawing management, equipment specification, handling of operator, received order, stock control, production results, system management, and so on. the proposed paper is designed and implemented based on RFID status management system to support monitoring services of diagnosis the failure status monitoring.

Development of a Prototype Monitoring Module for Steel Bridge Repainting Robots (강교량 재도장 로봇의 모니터링 모듈 시제품 개발)

  • Seo, Myoung Kook;Lee, Ho Yeon;Park, Il Hwan;Chang, Byoung Ha
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.15-22
    • /
    • 2020
  • With the need for efficient maintenance technology to reduce maintenance costs for steel bridges, repainting robots are being developed to automate the work in narrow and poor bridge spaces. The repainting robot is equipped with a blasting module to remove paint layers and contaminants. This study developed a prototype monitoring module to be mounted on the repainting robot. The monitoring module analyzes the condition of the painting surface through a camera installed in the front, guides the direction of movement of the robot, and provides the operator with a video to check the working status after blasting through a camera installed in the back. Various image visibility enhancement technologies were applied to the monitoring module to overcome worksite challenges where incomplete lighting and dust occurs.

Design and Analysis of the Basic Components for the Semiconductor Wafer Cleaning Equipment Monitoring System (반도체 웨이퍼 세정 장비 모니터링 시스템을 위한 기본 요소의 분석 및 설계)

  • Kang, Ho-Seok;Rim, Seong-Rak
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.1
    • /
    • pp.115-125
    • /
    • 2000
  • In this paper, we suggest the basic components of monitoring system for the semiconductor wafer cleaning equipment and a monitoring system model based on these components. Basic component is defined as a mandatory function which consists of communication with the control system, user interface, communication with the remote monitoring system, management of monitoring data and inter-task communication. We have defined the function of each component and the relation among them, and designed each component as a task. To evaluate the validity of the suggested model, we have implemented the basic components using the Visual C++ on Windows NT and applied them to the Monitoring System for the semiconductor wafer cleaning equipment.

  • PDF

Remote Monitoring Systems Using StrongARM (StrongARM을 이용한 원격 감시시스템)

  • 임홍식;남현도;강철구
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.259-264
    • /
    • 2003
  • In this paper, web based monitoring systems are implemented using embedded Linux. The external equipment is controlled via HTTP protocol and web browser program. HTTP protocol is ported into Linux. A micro web server program and external equipment control program are installed on-board memory using CGI to be accessed by web browser. Experimental result of the proposed web based monitoring systems can be used in automation systems and remote distributed control via internet using web browser.

  • PDF

A study of Partial Discharge Condition Monitoring Equipment In the Ultra High Voltage Gas-Insulated Switchgear(GIS) for Digital Sub-station application (디지털 변전소 적용을 위한 초고압 GIS 부분방전 상태감시장치 개발 연구)

  • Kim, Young-Noh;Cho, Young-Jun;Choi, Chul-Gang;Hwang, Chul-Min;Choi, Jae-Ok;Gang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1380-1381
    • /
    • 2008
  • By applying the digital sub-station, the change of various protect and measuring equipments has been applying. This paper is analyzed that the development of GIS partial discharge condition monitoring equipment is suited to the electricity IT technology and digital sub-station. It's constitution apply to be able to suit the data to high rank for GIS partial discharge condition monitoring equipment that is suited digital sub-station and Watch-dog module that be able to monitor the inner communication of the GIS partial discharge equipment. And then it also be able to apply of GIS partial discharge equipment when digital sub-station is applied.

  • PDF

Production Equipment Monitoring System Based on Cloud Computing for Machine Manufacturing Tools

  • Kim, Sungun;Yu, Heung-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.197-205
    • /
    • 2022
  • The Cyber Physical System(CPS) is an important concept in achieving SMSs(Smart Manufacturing Systems). Generally, CPS consists of physical and virtual elements. The former involves manufacturing devices in the field space, whereas the latter includes the technologies such as network, data collection and analysis, security, and monitoring and control technologies in the cyber space. Currently, all these elements are being integrated for achieving SMSs in which we can control and analyze various kinds of producing and diagnostic issues in the cyber space without the need for human intervention. In this study, we focus on implementing a production equipment monitoring system related to building a SMS. First, we describe the development of a fog-based gateway system that links physical manufacturing devices with virtual elements. This system also interacts with the cloud server in a multimedia network environment. Second, we explain the proposed network infrastructure to implement a monitoring system operating on a cloud server. Then, we discuss our monitoring applications, and explain the experience of how to apply the ML(Machine Learning) method for predictive diagnostics.

Safety assessment of Generation III nuclear power plant buildings subjected to commercial aircraft crash Part II: Structural damage and vibrations

  • Qu, Y.G.;Wu, H.;Xu, Z.Y.;Liu, X.;Dong, Z.F.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.397-416
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part II, based on the verified finite element (FE) models of aircrafts Airbus A320 and A380, as well as the NPP containment and auxiliary buildings in Part I of this paper, the whole collision process is reproduced numerically by adopting the coupled missile-target interaction approach with the finite element code LS-DYNA. The impact induced damage of NPP plant under four impact locations of containment (cylinder, air intake, conical roof and PCS water tank) and two impact locations of auxiliary buildings (exterior wall and roof of spent fuel pool room) are evaluated. Furthermore, by considering the inner structures in the containment and raft foundation of NPP, the structural vibration analyses are conducted under two impact locations (middle height of cylinder, main control room in the auxiliary buildings). It indicates that, within the discussed scenarios, NPP structures can withstand the impact of both two aircrafts, while the functionality of internal equipment on higher floors will be affected to some extent under impact induced vibrations, and A380 aircraft will cause more serious structural damage and vibrations than A320 aircraft. The present work can provide helpful references to assess the safety of the structures and inner equipment of NPP plant under commercial aircraft impact.

The Suggestion of Reliability Improvement Method based on Failure Trend Analysis of Chiller (냉동기 고장경향분석을 통한 설비신뢰도향상 방안 제시)

  • Lee, Sang Dae;Yeom, Dong Un;Hyun, Jin Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.251-255
    • /
    • 2015
  • Chiller system plays an important role of maintaining room temperature constantly by supplying chilled water to Heating, Ventilating and Air Conditioning(HVAC)or area room cooler equipment during plant normal operation or accident condition. Chiller failures are one of the most frequently occurring equipment failures. If the types of chiller failures are analyzed and grouped thoroughly, it would be helpful to make chiller maintenance strategy at the plants. That would enhance equipment reliability of chiller in the end. In this paper, chiller failure data during three years were analyzed and categorized by specific failure code. In addition, the various proposals to improve equipment reliability of chiller were suggested such as Preventive Maintenance Optimization(PMO) strategy and performance monitoring reinforcement and so on.