• Title/Summary/Keyword: Monitor

Search Result 7,293, Processing Time 0.033 seconds

Development of Monitor Positioning Algorithm considering Power System Topology and Distributed Generation (분산전원과 토폴로지를 고려한 배전계통에서의 전기품질 모니터 위치 선정 기법)

  • Moon, Dae-Seong;Kim, Yun-Seong;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1744-1751
    • /
    • 2008
  • This paper presents a monitor positioning algorithm to identify the power quality event source in the distribution system with distributed generations. This algorithm determines the appropriate number of monitors and their locations considering power system topology together with distributed generation. This paper summarizes the guidelines of monitor positioning into five principles and defines the weighting factors according to the principles. To evaluate the adequacy of monitor positioning results, ambiguity indices considering monitor location and system topology are proposed. The optimal number and locations of monitors are determined from optimization routine using the weighting factors and the monitor positioning results are evaluated in terms of ambiguity indices. The algorithm is applied to IEEE 13 bus test feeder and suggests the optimal number and locations of power quality monitors. The proposed approach can realize the expert's knowledge on monitor positioning into a sophisticated automatic computing algorithm.

A Study on the Preference of Feminine Seniors for the Higher Usability of Life Support Appliances (재가노인생활지원기기의 실용화를 위한 여성노인의 선호 연구)

  • Kim, Sun-Joong;Park, Kyoung-Ok
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.407-412
    • /
    • 2008
  • The purpose of this study is to find out the preference and the opinion of feminine seniors on the life support appliances(video phone, medication dispenser, activity monitor and sleep monitor). The appliances may be improved reflecting the result of the preferred functions and designs. The respondents were 141 feminine seniors of 65 years & older, living in Ulsan city or Cheongju city, Korea. Following is the result. 1) All the responses answered that the medication dispenser, video phone and activity monitor, sleep monitor are useful appliances. 2) All the seniors expressed prefer to function of the appliances, and were highly concerned about the price, safety and convenience. 3)The preferred designs were (1) white or red standing medication dispenser,(2) wall-mounted video phone working by voice, (3) metal activity monitor sensor like white or yellow bracelet.

  • PDF

Comparative Experimental Study on Color Meter for Monitor Color Correction (모니터 색상 보정을 위한 색측기 비교 실험에 관한 연구)

  • Han, Byung-Jo;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.444-449
    • /
    • 2010
  • The PID control to the monitor color correction was applied. Converted Gamma LUT was applied to the video card. Color and brightness information from the PID controller was used as control inputs. Color and brightness information from a calibrated monitor is measured again. Then, the difference between the preset values for the PID controller was compensated by the feedback. The software measured by color meter was used for color and brightness information. All of the monitor does not measure the color and brightness was measured by sampling. The color and brightness from the monitor were measured not by complete enumeration but by sampling. In the experiment, the original image was displayed on the same monitor as well as two other brands, and then, Gamma and Contrast were measured and compared.

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

Comparison of particle size distribution and particle number concentration measured by APS 3321 and Dust Monitor 1.108 (APS 3321과 Dust Monitor 1.108을 이용한 입자 크기분포 및 수농도 측정결과 비교)

  • Lim, Kyoung-Soo;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2009
  • The size distribution and number concentration of atmospheric aerosol were measured and compared using APS 3321 and Dust Monitor 1.108. The particle size distribution and number concentration measured by two devices were also compared at a particle generation system of standard PSL and fly ash. The number concentration of atmospheric aerosol measured by APS was higher than that by Dust Monitor in particle size range of less than $3.0{\mu}m$, but there was good accordance between them in particle size range of over $3.0{\mu}m$. In the particle generation system of PSL and fly ash, different measurement results were shown because the particle concentration was higher than that of atmospheric aerosol. The number concentration measured by Dust Monitor was higher than that by APS in most particle size ranges. However, the peak concentration of PSL particles measured by Dust Monitor was lower than that by APS. The difference of the collection efficiency in a scrubber by APS and Dust Monitor measurement was less than 10%, but in the particle size of $1.5{\mu}m$, it was over 20%.

  • PDF

Installation of Neutron Monitor at the Jang Bogo Station in Antarctica

  • Jung, Jongil;Oh, Suyeon;Yi, Yu;Evenson, Paul;Pyle, Roger;Jee, Geonhwa;Kim, Jeong-Han;Lee, Changsup;Sohn, Jongdae
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.345-348
    • /
    • 2016
  • In December 2015, we have installed neutron monitor at the Jang Bogo station in Antarctica. The Jang Bogo station is the second science station which is located at the coast ($74^{\circ}\;37.4^{\prime}S$, $164^{\circ}\;13.7^{\prime}E$) of Terra Nova Bay in Northern Victoria Land of Antarctica. A neutron monitor is an instrument to detect neutrons from secondary cosmic rays collided by the atmosphere. The installation of neutron monitor at Jang Bogo station is a part of transferred mission for neutron monitor at McMurdo station of USA. Among 18 tubes of 18-NM64 neutron monitor, we have completed relocation of 6 tubes and the rest will be transferred in December 2017. Currently, comparison of data from both neutron monitors is under way and there is a good agreement between the data. The neutron monitor at Jang Bogo station will be quite useful to study the space weather when the installation is completed.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Monitor Unit calculation through Excell program (Excell 프로그램을 통한 치료선량(M. U) 계산)

  • Lim, Guang-Chae;Cho, Eun-Ju;Cho, Sun-Hang
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 1999
  • Verifying the treatment value(Monitor Unit) unnecessarily involves too many simple and repetitive calculation processes, that is, individual computation process using the data(PDD value, Scp Factor, SSD Factor, Tray Factor) on the data book. We intend to minimize the time required to check the Monitor Unit through computerized calculation. Using $^{\ast}(multiplication)$, /(division), +(sum), if function, among others, which are present in the Excell program, MS office program, the Monitor Unit was obtainable through A/P value, Scp Factor and PDD value, Wedge Factor. From the verification of the computations of Monitor Unit for 60 patients previously treated, we were able to obtain an error rate of ${\pm}0.028MU$. Computerized calculation of the Monitor Unit could save the burden of Technologist.

  • PDF

포항 방사광 가속기 전자빔 진단용 계측제어

  • 원상철;장석상
    • 전기의세계
    • /
    • v.38 no.5
    • /
    • pp.68-77
    • /
    • 1989
  • Beam monitor는 beam이 발생하는 전장, 자장 또는 방사광등 beam에 의해 유기되는 ion을 관측하는 것과 같이 간접적으로 beam의 정보를 얻는 방법과 beam의 진로에 직접 sensor를 삽입해 전하입자로써의 beam과 장치를 구성하는 매질의 상호작용에 의해 정보를 얻는 방법으로 대변할 수 있다. monitor는 전극동의 검출기에 유기되는 신호level이 비교적 낮으므로 설계 제작시에는 대개의 경우 이론적인 계산을 그대로 설계에 적용할 수 있다. 따라서, 설계 제작시에는 동작원리등을 충분히 검토한 후에 설계해야 한다. monitor의 정도는 검출기의 기계설계와 회로설계의 적부에 의해 결정되기 때문이다. 한편 전자 beam에 의해 유기되는 전기적성질을 이용한 beam monitor에 비해 SR을 이용한 monitor의 경우에는 주위의 전기적인 noise의 영향을 전혀 받지 않는다는 점에 커다란 이점을 갖고 있다. PLS에서 목표로 하고 있는 제3세대 machine에서도 SR monitor는 중시되고 있다.

  • PDF

Analysis of Thermal Distribution inside LCD Monitor by Development of Prediction Formula for Inner Temperature (내부 온도 추정식 개발에 의한 LCD 모니터 내부의 열분포 분석)

  • Oh, S.J.;Ko, H.S.;Chung, D.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.487-488
    • /
    • 2006
  • In these days, demand of a LCD monitor is remarkably increasing with development of the LCD technology. However, there are thermal problems for improvement of efficiency for the LCD monitor. Thus, this research analyzed thermal problems such as convection and conduction heat transfer characteristics in the LCD monitor using an infrared (IR) camera. Also, the results of the outer side of the front LCD panel using the IR camera have been compared with the results of the inner side of the front panel using T-type thermocouples. The equations have been derived for the temperature distribution of the inner side of the front LCD panel by a multiple regression method including variables for ambient temperature, humidity and temperature differences between the front and back panels of the LCD monitor.

  • PDF