• Title/Summary/Keyword: Monitor

Search Result 7,341, Processing Time 0.032 seconds

A Design and Implementation of a Remote Status Monitor and Control System for an ADS-B System (ADS-B 시스템 상태 감시 및 원격 제어 시스템의 설계와 구현)

  • Jang, Eunmee;Song, Inseong;Yoon, Wanoh;Choi, Sangbang
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.4
    • /
    • pp.325-333
    • /
    • 2014
  • An ADS-B system, which is a critical technology in surveillance area of the CNS/ATM, can replace or compensate a conventional radar based surveillance system through the communications among aircrafts. An ADS-B ground system which is to use the ADS-B on the ground air traffic management system consists of various subsystem devices such as ground stations that communicate with the aircrafts, and ADS-B/TIS-B/FIS-B servers. The ADS-B ground system has a form of distributed system and is interconnected through the network. Therefore, a system which can monitor and control the status of the multiple subsystem devices of the ADS-B ground system is essential. In this paper, we designed and implemented a remote status monitor and control system for the ADS-B system that can monitor and control the subsystem devices of the ADS-B system in remote place via SNMP protocol.

Development of Monitor Chamber Prototype and Basic Performance Testing (모니터 전리함 시작품 개발과 기초 성능 평가)

  • Lee, Mujin;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Rhee, Dong Joo;Kang, Sang Koo;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.99-105
    • /
    • 2015
  • The monitor chamber is a real time dosimetry device for the measurement and the control of radiation beam intensity of the linac system. The monitor chamber prototype was developed for monitoring and controlling radiation beam from the linac based radiation generator. The thin flexible printed circuit boards were used for electrodes of the two independent plane-parallel ionization chambers to minimize the attenuation of radiation beam. The dosimetric characteristics, saturation and linearity of the measured charge, were experimentally evaluated with the Co-60 gamma rays. The performance of the developed monitor chamber prototype was in an acceptable range and this study shows the possibility of the further development of the chamber with additional functions.

Numerical Investigation of the Effect of flow Passage Variation on the Projection Distance of the Foam Monitor (유로형상변경에 따른 폼 모니터 분사거리 변화의 수치적 해석)

  • Lee, Young-Hoon;RYU, Young-Chun;Seong, Jeong-Hyun;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.244-251
    • /
    • 2016
  • In this study, the relationship between flow characteristics and projection distance, depending on the shape was examined. A numerical investigation technique for fluid analysis of a foam monitor was developed for the prediction, comparison and validation of the actual injection performance. The foam monitor changes the flow pattern of fluid flow according to the shape, The fluid losses were calculated from the numerical investigation affecting the projection distance. The basic form of foam monitor was used as a designed shape in N. The modified model used the length increase model of the flow path, and straight line of the model. The inlet pressure was 6.5bar. The results showed that the length increase model of the flow path and straight line of the model in the nozzle projection distance had improved. The results comparing the error rates projection performance were well matched to the 7.43% obtained from the validity test of the analysis method.

Study of Computational Fluid Dynamics for Projection Distance Prediction of the Foam Monitor (폼모니터의 분사거리 예측을 위한 유동해석에 관한 연구)

  • Ryu, Young-Chun;Seo, Bu-Kyo;Seung, Jung-Hyun;Lee, Young-Hoon;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5939-5944
    • /
    • 2014
  • The foam monitor is equipment for extinguishing fires, particularly for oil tankers or cargo areas of the carrying vessel. This equipment is installed on the cargo tank deck. Generally, the projection distance is important for designing an extinguishment. On the other hand, the form monitors in current industry have been designed by trial and error rather than by numerical analysis method. Therefore, the shape design of the new form of monitor is needed. In this study, numerical analysis was performed to determine the projection distance prediction, and experiment results were used to make a comparison with the analysis results. The proposed method was applied to the modified form of a newly designed monitor in a company.

Real-Time Detection on FLUSH+RELOAD Attack Using Performance Counter Monitor (Performance Counter Monitor를 이용한 FLUSH+RELOAD 공격 실시간 탐지 기법)

  • Cho, Jonghyeon;Kim, Taehyun;Shin, Youngjoo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.6
    • /
    • pp.151-158
    • /
    • 2019
  • FLUSH+RELOAD attack exposes the most serious security threat among cache side channel attacks due to its high resolution and low noise. This attack is exploited by a variety of malicious programs that attempt to leak sensitive information. In order to prevent such information leakage, it is necessary to detect FLUSH+RELOAD attack in real time. In this paper, we propose a novel run-time detection technique for FLUSH+RELOAD attack by utilizing PCM (Performance Counter Monitor) of processors. For this, we conducted four kinds of experiments to observe the variation of each counter value of PCM during the execution of the attack. As a result, we found that it is possible to detect the attack by exploiting three kinds of important factors. Then, we constructed a detection algorithm based on the experimental results. Our algorithm utilizes machine learning techniques including a logistic regression and ANN(Artificial Neural Network) to learn from different execution environments. Evaluation shows that the algorithm successfully detects all kinds of attacks with relatively low false rate.

Timber Loading Productivity of Remote Controlled Forestry Equipment Through Image of Monitor (모니터 영상을 통한 원격제어 임업용 장비의 원목상차작업 생산성)

  • Choi, Yun-Sung;Cho, Min-Jae;Oh, Jae-Heun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.3
    • /
    • pp.363-371
    • /
    • 2021
  • Forest operations like timber harvesting have already been mechanized to reduce hazards to the worker and increase productivity. However, timber harvesting operations have still been considered potentially dangerous and expensive on steep terrain. Teleoperation, to control the timber harvesting machine at a distance, has the potential to improve the safety, productivity and efficiency of harvesting operations on steep terrain. To verify the effects of teleoperation, an experimental prototype system of a monitor image-based teleoperation was constructed using a real forestry machine. In this study, the productivity of excavator based grapple loader, which is one of the most used mechanized harvesting equipment in the timber production, was analyzed using time-study method. Factors like skill and age of operators, influencing loader productivity in timber loading operation were also evaluated by statistical analysis. Productivity analysis results showed that less experienced operators were more productive than experienced operators for teleoperation through image of monitors in the operator cabin. These results are shown to be unfamiliar to the monitor image and different loading operation pattern by operators. According to the results, the monitor image-based teleoperation system of forestry machine need to improve the resolution and installation position of camera. It was expected that additional studies will be needed for real-time remote control of forestry machine in the future.

Machine Learning-Based Detection of Cache Side Channel Attack Using Performance Counter Monitor of CPU (Performance Counter Monitor를 이용한 머신 러닝 기반 캐시 부채널 공격 탐지)

  • Hwang, Jongbae;Bae, Daehyeon;Ha, Jaecheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.6
    • /
    • pp.1237-1246
    • /
    • 2020
  • Recently, several cache side channel attacks have been proposed to extract secret information by exploiting design flaws of the microarchitecture. The Flush+Reload attack, one of the cache side channel attack, can be applied to malicious application attacks due to its properties of high resolution and low noise. In this paper, we proposed a detection system, which detects the cache-based attacks using the PCM(Performance Counter Monitor) for monitoring CPU cache activity. Especially, we observed the variation of each counter value of PCM in case of two kinds of attacks, Spectre attack and secret recovering attack during AES encryption. As a result, we found that four hardware counters were sensitive to cache side channel attacks. Our detector based on machine learning including SVM(Support Vector Machine), RF(Random Forest) and MLP(Multi Level Perceptron) can detect the cache side channel attacks with high detection accuracy.

Development of Wireless Communication Based Operation State Monitoring System for Open Rack Vaporizer (무선 통신 기반 해수식 기화기 운영 상태 모니터링 시스템 개발)

  • Yoo, Seung-Yeol;Joen, Ming-Sung;Lee, Jae-Chul;Kang, Dong-Hoon;Kim, Dong-Goen;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.280-287
    • /
    • 2022
  • An open rack vaporizer is a facility that vaporizes liquefied natural gas using sea water. When a vaporization efficiency of the open rack vaporizer decreases, liquefied natural gas can leak, which can cause great damage to the facility. Operators have to monitor the operation state of the facility in real-time to prevent the accident. However, operators have visited the site and have checked the state by looking at the value of sensors installed in the open rack vaporizer through indicators. For the safe operation of the open rack vaporizer, a monitoring system is needed to monitor the operation state of the open rack vaporizer in real-time without the need for operators to visit the site. In this paper, we developed a long term evolution based monitoring system to monitor the operation state of the open rack vaporizer. The developed system can monitor the real-time operation state of the open rack vaporizer at a control center far from the facility. For the system development, data transmission infrastructure using long term evolution was built. Afterwards a software was developed to monitor the operation state of the open rack vaporizer in real-time using the transmitted data. Finally, performance evaluation was conducted to confirm that the developed system operated successfully without data transmission delay or data missing.

A rapid modeling method and accuracy criteria for common-cause failures in Risk Monitor PSA model

  • Zhang, Bing;Chen, Shanqi;Lin, Zhixian;Wang, Shaoxuan;Wang, Zhen;Ge, Daochuan;Guo, Dingqing;Lin, Jian;Wang, Fang;Wang, Jin
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.103-110
    • /
    • 2021
  • In the development of a Risk Monitor probabilistic safety assessment (PSA) model from the basic PSA model of a nuclear power plant, the modeling of common-cause failure (CCF) is very important. At present, some approximate modeling methods are widely used, but there lacks criterion of modeling accuracy and error analysis. In this paper, aiming at ensuring the accuracy of risk assessment and minimizing the Risk Monitor PSA models size, we present three basic issues of CCF model resulted from the changes of a nuclear power plant configuration, put forward corresponding modeling methods, and derive accuracy criteria of CCF modeling based on minimum cut sets and risk indicators according to the requirements of risk monitoring. Finally, a nuclear power plant Risk Monitor PSA model is taken as an example to demonstrate the effectiveness of the proposed modeling method and accuracy criteria, and the application scope of the idea of this paper is also discussed.

Performance Assessment of GBAS Ephemeris Monitor for Wide Faults (Wide Fault에 대한 GBAS 궤도 오차 모니터 성능 분석)

  • Junesol Song;Carl Milner
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.2
    • /
    • pp.189-197
    • /
    • 2024
  • Galileo is a European Global Navigation Satellite System (GNSS) that has offered the Galileo Open Service since 2016. Consequently, the standardization of GNSS augmentation systems, such as Satellite Based Augmentation System (SBAS), Ground Based Augmentation System (GBAS), and Aircraft Based Augmentation System (ABAS) for Galileo signals, is ongoing. In 2023, the European Union Space Programme Agency (EUSPA) released prior probabilities of a satellite fault and a constellation fault for Galileo, which are 3×10-5 and 2×10-4 per hour, respectively. In particular, the prior probability of a Galileo constellation fault is significantly higher than that for the GPS constellation fault, which is defined as 1×10-8 per hour. This raised concerns about its potential impact on GBAS integrity monitoring. According to the Global Positioning System (GPS) Standard Positioning Service Performance Standard (SPS PS), a constellation fault is classified as a wide fault. A wide fault refers to a fault that affects more than two satellites due to a common cause. Such a fault can be caused by a failure in the Earth Orientation Parameter (EOP). The EOP is used when transforming the inertial axis, on which the orbit determination is based, to Earth Centered Earth Fixed (ECEF) axis, accounting for the irregularities in the rotation of the Earth. Therefore, a faulty EOP can introduce errors when computing a satellite position with respect to the ECEF axis. In GNSS, the ephemeris parameters are estimated based on the positions of satellites and are transmitted to navigation satellites. Subsequently, these ephemeris parameters are broadcasted via the navigation message to users. Therefore, a faulty EOP results in erroneous broadcast ephemeris data. In this paper, we assess the conventional ephemeris fault detection monitor currently employed in GBAS for wide faults, as current GBAS considers only single failure cases. In addition to the existing requirements defined in the standards on the Probability of Missed Detection (PMD), we derive a new PMD requirement tailored for a wide fault. The compliance of the current ephemeris monitor to the derived requirement is evaluated through a simulation. Our findings confirm that the conventional monitor meets the requirement even for wide fault scenarios.