• 제목/요약/키워드: Momentum flux

검색결과 180건 처리시간 0.022초

동축형 제트 분사기의 화염 및 연소 안정성 특성에 관한 실험적 연구 (An Experimental Study On Characteristics of Flame and Combustion Stability of Coaxial Jet Injectors)

  • 손진우;민용호;손채훈
    • 한국연소학회지
    • /
    • 제21권2호
    • /
    • pp.15-21
    • /
    • 2016
  • Flame characteristics and combustion stability of a swirl coaxial injector are studied experimentally. Characteristics of flame and combustion instability are analyzed with the parameter of MFR (momentum flux ratio) using hexane instead of kerosene. Flame patterns of blue and yellow are changed with variable MFR. Combustion instabilities are measured and analyzed by adopting a model chamber. Combustion instability mapping is made by evaluating damping factor at the 2 L (second longitudinal) mode with variable MFR in 63 cases for operating condition.

A Far Field Solution of the Slowly Varying Drift Force on an Offshore Structure in Bichromatic Waves - Two Dimensional Problems

  • 이상무
    • 한국해양공학회지
    • /
    • 제22권2호
    • /
    • pp.7-12
    • /
    • 2008
  • A far field solution of the slowly varying force on an offshore structure by gravity ocean waves was shown as a function of the reflection and transmission of the body disturbed waves. The solution was obtained from the conservation of the momentum flux, which simply describes various wave forces, while making it unnecessary to compute complicated integration over a control surface. The solution was based on the assumption that the frequency difference of the bichromatic incident waves is small and its second order term is negligible. The final solution is expressed in term of the reflection and transmission waves, i.e. their amplitudes and phase angles. Consequently, it shows that not only the amplitudes but also the phase differences make critical contributions to the slowly varying force. In a limiting case, the slowly varying force solution gives the one of the mean drift force, which is only dependent on the reflection wave amplitude. An approximation is also suggested in a case where only the mean drift force information is available.

Empirical Correlations for Penetration Height of Liquid Jet in Uniform Cross Flow - A Review

  • No, Soo-Young
    • 한국분무공학회지
    • /
    • 제16권4호
    • /
    • pp.176-185
    • /
    • 2011
  • The empirical correlations for the prediction of penetration height of liquid jet in crossflow are reviewed and classified in this study. Around thirty different correlations had been proposed by many investigators. It has generally known that the penetration height of a liquid jet in a cross-flow is a function of the liquid to air momentum flux ratio and the normalized downstream distance from the injector. However, several researchers incorporated the Weber number, liquid-to-water or air viscosity ratio, pressure ratio or Reynolds number, temperature ratio in the empirical correlations. The existing correlations can be grouped as correlations in a power-law, logarithmic, and exponential forms, respectively. Correlations in a power-law form can be further classified as three groups such as basic form, Weber number form and other parameters form. It should be pointed out that correlations in a logarithmic form in terms of Weber number or any other parameters could not be found. Universal correlation has still not been established due to the significant discrepancies between various correlations suggested to date. Several of the studies reported the significant discrepancies of predicted values by the existing correlations. The possible reasons for discrepancies will be summarized as measurement technique, assumptions made in defining terms in the liquid to air momentum flux ratio, difficulties in defining the boundaries of the liquid jets, and nozzle/injector geometry. Evaluation of validity for the correlations proposed recently by several investigators is essentially required. Those include eight power-law forms, two logarithmic forms, and one exponential form.

분사조건에 따른 기체/액체 동축형 인젝터의 분무특성에 관한 연구 (A Study on Characteristics of Gas/Liquid Coaxial Sprays Under Varying Flow Conditions)

  • 정원호;김동준;임지혁;윤영빈
    • 한국항공우주학회지
    • /
    • 제33권1호
    • /
    • pp.54-61
    • /
    • 2005
  • 기체와 액체 추진제를 사용하는 동축형 분사기의 분무특성을 조사하기 위하여 shadow graph와 mechanical patternator, PDPA를 이용한 실험을 수행하였다. 차원해석 방법을 도입하여 운동량 플럭스 비(M)와 레이놀즈 수(Re)를 기체/액체 동축형 분무의 주요 변수로 설정하였고, 실험을 통하여 전단 및 스월 동축형 분무의 특성을 거시적 및 미시적 관점에서 비교분석하였는데, 기체 추진제의 영향력이 커지는 분사조건에서 전단 및 스월 동축형 분무의 거시적 특성이 유사해짐을 확인할 수 있었다. 또한, 본 연구에서는 미시적 분무특성에 대한 분석 결과로서 분무액적 크기와 분사조건 사이의 관계식도 제시하였다.

Empirical Correlations for Breakup Length of Liquid Jet in Uniform Cross Flow-A Review

  • No, Soo-Young
    • 한국분무공학회지
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2013
  • The empirical correlations for the prediction of breakup length of liquid jet in uniform cross flow are reviewed and classified in this study. The breakup length of liquid jets in cross flow was normally discussed in terms of the distances from the nozzle exit to the column breakup location in the x and y directions, called as column fracture distance and column fracture height, respectively. The empirical correlations for the prediction of column fracture distance can be classified as constant form, momentum flux ratio form, Weber number form and other parameter form, respectively. In addition, the empirical correlations for the prediction of column fracture height can be grouped as momentum flux ratio form, Weber number form and other parameter form, respectively. It can be summarized that the breakup length of liquid jet in a cross flow is a basically function of the liquid to air momentum flux ratio. However, Weber number, liquid-to-air viscosity ratio and density ratio, Reynolds number or Ohnesorge number were incorporated in the empirical correlations depending on the investigators. It is clear that there exist the remarkable discrepancies of predicted values by the existing correlations even though many correlations have the same functional form. The possible reasons for discrepancies can be summarized as the different experimental conditions including jet operating condition and nozzle geometry, measurement and image processing techniques introduced in the experiment, difficulties in defining the breakup location etc. The evaluation of the existing empirical correlations for the prediction of breakup length of liquid jet in a uniform cross flow is required.

큰에디모의 모형을 이용한 높은 레이놀즈 수에서의 사각 기둥 후면의 와열 분석: 풍향과 풍속, 기둥 너비의 영향 (Analysis on Vortex Streets Behind a Square Cylinder at High Reynolds Number Using a Large-Eddy Simulation Model: Effects of Wind Direction, Speed, and Cylinder Width)

  • 한범순;곽경환;백종진
    • 대기
    • /
    • 제27권4호
    • /
    • pp.445-453
    • /
    • 2017
  • This study investigates turbulent flow around a square cylinder mounted on a flat surface at high Reynolds number using a large-eddy simulation (LES) model, particularly focusing on vortex streets behind the square cylinder. Total 9 simulation cases with different inflow wind directions, inflow wind speeds, and cylinder widths in the x- and y-directions are considered to examine the effects of inflow wind direction, speed, and cylinder widths on turbulent flow and vortex streets. In the control case, the inflow wind parallel to the x-direction has a maximum speed of $5m\;s^{-1}$ and the width and height of the cylinder are 50 m and 200 m, respectively. In all cases, down-drafts in front of the cylinder and updrafts, wakes, and vortex streets behind the cylinder appear. Low-speed flow below the cylinder height and high-speed flow above it are mixed behind the cylinder, resulting in strong negative vertical turbulent momentum flux at the boundary. Accordingly, the magnitude of the vertical turbulent momentum flux is the largest near the cylinder top. In the case of an inflow wind direction of $45^{\circ}$, the height of the boundary is lower than in other cases. As the inflow wind speed increases, the magnitude of the peak in the vertical profile of mean turbulent momentum flux increases due to the increase in speed difference between the low-speed and high-speed flows. As the cylinder width in the y-direction increases, the height of the boundary increases due to the enhanced updrafts near the top of the cylinder. In addition, the magnitude of the peak of the mean turbulent momentum flux increases because the low-speed flow region expands. Spectral analysis shows that the non-dimensional vortex generation frequency in the control case is 0.2 and that the cylinder width in the y-direction and the inflow wind direction affect the non-dimensional vortex generation frequency. The non-dimensional vortex generation frequency increases as the projected width of the cylinder normal to the inflow direction increases.

웨버수 및 운동량 플럭스비에 따른 동축형 다공성재 분사기의 거시적 분무특성 (Effect of Weber Number and Momentum Flux Ratio on Macroscopic Characteristics of Spray from a Coaxial Porous Injector)

  • 김도헌;서민교;이인철;구자예
    • 한국추진공학회지
    • /
    • 제16권5호
    • /
    • pp.1-9
    • /
    • 2012
  • 동축형 다공성재 분사기에서는 중심 액체제트 주위를 둘러싼 원통형 다공성재의 내부 표면에서 반경방향으로 분사된 기체가 중심액체제트와 상호작용을 하게 된다. 표면분사된 기체제트는 반경방향에서 축방향으로 발달하며, 그 과정에서 액체분무의 중심부까지 운동량을 효과적으로 전달하여 미립화 및 혼합 성능을 향상시킨다. 본 연구에서는 기체분사 면적 및 기체분사 질량유량을 변화시켜 각각 운동량 비 및 웨버수의 크기를 조절하였으며, 이에 따른 물-공기 모사추진제 수류시험에서의 분무특성에 대한 고찰을 수행하고 동일 스케일의 전단 동축형 분사기와의 비교 분석이 이루어졌으며, 동축형 다공성재 분사기에서 반경방향으로의 기체분사가 2상유체의 미립화/혼합에 긍정적인 영향을 주는 것으로 판단된다.

MEASUREMENT OF THE SINGLE AND TWO PHASE FLOW USING A NEWLY DEVELOPED AVERAGE BIDIRECTIONAL FLOW TUBE

  • Yun, Byong-Jo;Euh, Dong-Jin;Kang, Kyunc-Ho;Song, Chul-Hwa;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.595-604
    • /
    • 2005
  • A new instrument, an average BDFT (Birectional Flow Tube), was proposed to measure the flow rate in single and two phase flows. Its working principle is similar to that of the Pilot tube, wherein the dynamic pressure is measured. In an average BDFT, the pressure measured at the front of the flow tube is equal to the total pressure, while that measured at the rear tube is slightly less than the static pressure of the flow field due to the suction effect downstream. The proposed instrument was tested in air/water vertical and horizontal test sections with an inner diameter of 0.08m. The tests were performed primarily in single phase water and air flow conditions to obtain the amplification factor(k) of the flow tube in the vertical and horizontal test sections. Tests were also performed in air/water vertical two phase flow conditions in which the flow regimes were bubbly, slug, and churn turbulent flows. In order to calculate the phasic mass flow rates from the measured differential pressure, the Chexal drift-flux correlation and a momentum exchange factor between the two phases were introduced. The test results show that the proposed instrument with a combination of the measured void fraction, Chexal drift-flux correlation, and Bosio & Malnes' momentum exchange model could predict the phasic mass flow rates within a $15\%$ error. A new momentum exchange model was also proposed from the present data and its implementation provides a $5\%$ improvement to the measured mass flow rate when compared to that with the Bosio & Malnes' model.

드리프트 플럭스 모델과 2-유체 모델 사이의 상관 관계 (Interrelationship Between the Drift-flux Model and the Two-fluid Model)

  • No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.233-236
    • /
    • 1993
  • 상 변화가 없고 압력 변화가 없는 일차원 이상 유동에 있어서 드리프트 플럭스 모델자 2-유체 모델 사이의 상관 관계가 연구되었다. 증기 보존식은 드리프트 플럭스를 통하여 운동량 보존식에 의존한다는 사실에 기초하여 관계가 얻어졌다. 2-유체 모델로부터 출발하여 트리프트 플럭스의 파라미터의 함수로 표현된 계면 마찰식을 얻었다. 또한 기공 전달식을 유도함으로써 드리프트 플럭스는 2-유체 모델의 마찰력과 상호 관계가 있음을 보였다.

  • PDF

Study on dryout heat flux of axial stratified debris bed under top-flooding

  • Wenbin Zou;Lili Tong;Xuewu Cao
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.636-643
    • /
    • 2024
  • The coolability of the debris bed with a simulant of solidified corium is experimentally studied, focusing on the effects of the structure of the axial stratified debris bed on the dryout heat flux (DHF). DHF was obtained for the four structures with different particle sizes for the axial stratified debris bed under top flooding. The experimental results show that the dryout position of the axial stratified debris bed is formed at the stratified interface indicated by the temperature rise, and the DHF of the axial stratified bed is much lower than that of the homogeneous bed packed with the upper small particles. To predict the dryout heat flux of the stratified debris beds, by considering the properties of the mixed area, a one-dimensional dryout heat flux model of the porous medium is derived from a water and vapor momentum equation for porous medium, two-phase permeability modifications, interfacial drag, and the correlation between capillary pressure and liquid saturation and verified with the experimental data. The modified model can give reasonable results under different structures.