Effect of fiber reinforcing on instantaneous deflection of self-compacting concrete one-way slabs under early-age loading

  • Vakhshouri, Behnam;Nejadi, Shami
    • Structural Engineering and Mechanics
    • /
    • 제67권2호
    • /
    • pp.155-163
    • /
    • 2018
  • The Early-age construction loading and changing properties of concrete, especially in the multi-story structures can affect the slab deflection, significantly. Based on previously conducted experiment on eight simply-supported one-way slabs this paper investigates the effect of concrete type, fiber type and content, loading value, cracking moment, ultimate moment and applied moment on the instantaneous deflection of Self-Compacting Concrete (SCC) slabs. Two distinct loading levels equal to 30% and 40% of the ultimate capacity of the slab section were applied on the slabs at the age of 14 days. A wide range of the existing models of the effective moment of inertia which are mainly developed for conventional concrete elements, were investigated. Comparison of the experimental deflection values with predictions of the existing models shows considerable differences between the recorded and estimated instantaneous deflection of SCC slabs. Calculated elastic deflection of slabs at the ages of 14 and 28 days were also compared with the experimental deflection of slabs. Based on sensitivity analysis of the effective parameters, a new model is proposed and verified to predict the effective moment of inertia in SCC slabs with and without fiber reinforcing under two different loading levels at the age of 14 days.

Capacity and the moment-curvature relationship of high-strength concrete filled steel tube columns under eccentric loads

  • Lee, Seung-Jo
    • Steel and Composite Structures
    • /
    • 제7권2호
    • /
    • pp.135-160
    • /
    • 2007
  • Recently, CFT column has been well-studied and reported on, because a CFT column has certain superior structural properties as well as good productivity, execution efficiency, and improved rigidity over existing columns. However, CFT column still has problems clearing the capacity evaluation between its steel tube member and high-strength concrete materials. Also, research on concrete has examined numerical values for high-strength concrete filled steel square tube columns (HCFT) to explain transformation performance (M-${\phi}$) when a short-column receives equal flexure-moment from axial stress. Moment-curvature formulas are proposed for HCFT columns based on analytic assumption described in this paper. This study investigated structural properties (capacity, curvature), through a series of experiments for HCFT with key parameters, such as strength of concrete mixed design (58.8 MPa), width-thickness ratio (D/t), buckling length to sectional width ratio (Lk/D) and concrete types (Zeolite, Fly-ash, Silica-fume) under eccentric loads. A comparative analysis executed for the AISC-LRFD, AIJ and Takanori Sato, etc. Design formulas to estimate the axial load (N)-moment (M)-curvature (${\phi}$) are proposed for HCFT columns based on tests results described in this paper.

Predicting the moment capacity of RC slabs with insulation materials exposed to fire by ANN

  • Erdem, Hakan
    • Structural Engineering and Mechanics
    • /
    • 제64권3호
    • /
    • pp.339-346
    • /
    • 2017
  • Slabs prevent harmful effects of fire that may occur in any floor. However, it is necessary to protect the slabs from fire. Insulation materials may be appropriate to protect reinforced concrete (RC) slab from elevated temperature. In the present study, a model has been developed in artificial neural network (ANN) to predict the moment capacity ($M_r$) of RC slabs exposed to fire with insulation material. 672 data were obtained for ANN model through author's prepared program. Input layer in model consisted of seven input parameters; such as effective depth (d), ratio of d'/d, thermal conductivity coefficient ($k_{insulation}$), insulation materials thickness ($L_{insulation}$), reinforcement area ($A_{st}$), fire exposure time ($t_{\exp}$), and concrete compressive strength ($f_c$). The predicted $M_r$ by ANN was consistent with the obtained $M_r$ by author. It is proposed to ease computational complexity in determining $M_r$ using ANN. The effects of using insulation material on the moment capacity in RC slabs were also investigated. Insulating material with low thermal conductivity has been found to be more effective for durability to high temperature.

Component method model for predicting the moment resistance, stiffness and rotation capacity of minor axis composite seat and web site plate joints

  • Kozlowski, Aleksander
    • Steel and Composite Structures
    • /
    • 제20권3호
    • /
    • pp.469-486
    • /
    • 2016
  • Codes EN 1993 and EN 1994 require to take into account actual joint characteristics in the global analysis. In order to implement the semi-rigid connection effects in frame design, knowledge of joint rotation characteristics ($M-{\phi}$ relationship), or at least three basic joint properties, namely the moment resistance $M_R$, the rotational stiffness $S_j$ and rotation capacity, is required. To avoid expensive experimental tests many methods for predicting joint parameters were developed. The paper presents a comprehensive analytical model that has been developed for predicting the moment resistance $M_R$, initial stiffness $S_{j.ini}$ and rotation capacity of the minor axis, composite, semi-rigid joint. This model is based on so-called component method included in EN 1993 and EN 1994. Comparison with experimental test results shows that a quite good agreement was achieved. A computer program POWZ containing proposed procedure were created. Based on the numerical simulation made with the use of this program and applying regression analysis, simplified equations for main joint properties were also developed.

Effective Punching Shear and Moment Capacity of Flat Plate-Column Connection with Shear Reinforcements for Lateral Loading

  • Song, Jin-Kyu;Kim, Ju-Bum;Song, Ho-Bum;Song, Jeong-Won
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권1호
    • /
    • pp.19-29
    • /
    • 2012
  • In this study, three isolated interior flat slab-column connections that include three types of shear reinforcement details; stirrup, shear stud and shear band were tested under reversed cyclic lateral loading to observe the capacity of slab-column connections. These reinforced joints are 2/3 scale miniatures designed to have identical punching capacities. These experiments showed that the flexural failure mode appears in most specimens while the maximum unbalanced moment and energy absorbing capacity increases effectively, with the exception of an unreinforced standard specimen. Finally, the results of the experiments, as wel l as those of experiments previously carried out by researchers, are applied to the eccentricity shear stress model presented in ACI 318-08. The failure mode is therefore defined in this study by considering the upper limits for punching shear and unbalanced moment. In addition, an intensity factor is proposed for effective widths of slabs that carry an unbalanced moment delivered by bending.

Enhancing seismic performance of ductile moment frames with delayed wire-rope bracing using middle steel plate

  • Ghalandari, Akram;Ghasemi, Mohammad Reza;Dizangian, Babak
    • Steel and Composite Structures
    • /
    • 제28권2호
    • /
    • pp.139-147
    • /
    • 2018
  • Moment frames have considerable ductility against cyclic lateral loads and displacements; however, sometimes this feature causes the relative displacement to exceed the permissible limits. This issue can bring unfavorable hysteretic behavior on the frame due to the reduction in the stiffness and resistance against lateral loads. Most of common bracing systems usually control lateral displacements through increasing stiffness while result in decreasing the capacity for energy absorption. This has direct effect on hysteresis curves of moment frames. Therefore, a system that is capable of both having the capacity of energy absorption as well as controlling the displacements without a considerable increase in the stiffness is quite important. This paper investigates retrofitting of a single-storey steel moment frame using a delayed wire-rope bracing system equipped with the ductile middle steel plate. The steel plate is considered at the middle intersection of wire ropes, where it causes cables to be continuously in tension. This integrated system has the advantage of reducing considerable stiffness of the frame compared to cross bracing systems as a result of which it could also preserve the frame's energy absorption capacity. In this paper, FEM models of a delayed wire-rope bracing system equipped by steel plates with different geometries have been studied, validated, and compared with other researchers' laboratory test results.

스터드 커넥터로 연결된 H형강보의 모멘트 하중의 전달성능 (Moment Transmission Capacity of H-shaped Beam by Stud Connectors)

  • 이명재;최완철;이상구;김재희;김희동
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.639-648
    • /
    • 2003
  • 연구의 목적은 H형강보에 작용하는 매달림 하중 중 면내 및 면외 모멘트를 그 대상으로 구조설계시 적용되는 설계하중에 대하여 면내 및 면외 모멘트가 스터드 커넥터를 통하여 슬래브를 전달되는 하중전달 경로와 그 성능을 파악하는데 있다. 이를 위하여 면내 및 면외 모멘트를 받는 경우에 대하여 각각 2개의 실험체를 대상으로 가력실험 및 수치해석을 수행하였다. 실험의 변수로는 H형강보의 크기가 적용되었다. 면내 및 면의 모멘트 가력실험결과 현행 강구조계산기준을 따라 설계하면 스터드 커넥터에 의한 H형강보의 모멘트 전달성능을 설계하중을 만족하고 있음을 확인하였다.

Seismic performance of exterior R/C beam-column joint under varying axial force

  • Hu, Yanbing;Maeda, Masaki;Suzuki, Yusuke;Jin, Kiwoong
    • Structural Engineering and Mechanics
    • /
    • 제78권5호
    • /
    • pp.623-635
    • /
    • 2021
  • Previous studies have suggested the maximum experimental story shear force of beam-column joint frame does not reach its theoretical value due to beam-column joint failure when the column-to-beam moment capacity ratio was close to 1.0. It was also pointed out that under a certain amount of axial force, an axial collapse and a sudden decrease of lateral load-carrying capacity may occur at the joint. Although increasing joint transverse reinforcement could improve the lateral load-carrying capacity and axial load-carrying capacity of beam-column joint frame, the conditions considering varying axial force were still not well investigated. For this purpose, 7 full-scale specimens with no-axial force and 14 half-scale specimens with varying axial force are designed and subjected to static loading tests. Comparing the experimental results of the two types of specimens, it has indicated that introducing the varying axial force leads to a reduction of the required joint transverse reinforcement ratio which can avoid the beam-column joint failure. For specimens with varying axial force, to prevent beam-column joint failure and axial collapse, the lower limit of joint transverse reinforcement ratio is acquired when given a column-to-beam moment capacity ratio.

강종 및 보강방법에 따른 대골형 파형강판 합성부재의 휨성능에 관한 실험적 연구 (An Experimental Study on Flexural Strength of Deep Corrugated Steel Plate Composite Members by Steel Grade and Reinforcement Method)

  • 김용재;오홍섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.1-12
    • /
    • 2017
  • 본 연구에서는 대골형 파형강판 합성부재의 구성요소를 고강도 재료로 대체하고 이음방법, 전단보강방법 등 단면구성방법에 따른 단위부재의 휨거동을 분석하여 대골형 파형강판 합성부재 구조물의 장대화 및 적용범위확대를 위한 기초자료를 제시하고자 하였다. GR40과 SS590 강재를 적용한 합성구조체의 휨실험 결과, SS590 파형강판을 적용한 경우 정모멘트 하중저항성능은 약 28%가 증가되는 것으로 확인되었으나 부모멘트 저항성능은 미미한 것으로 확인되었다. 볼트의 개수를 증가시킨 파형강판 이음방법의 정모멘트 및 부모멘트 저항성능증가율은 높지 않은 것으로 확인되었다. 이는 고강도 재료에 따른 볼트의 접합 특성(볼트중심에서 연단까지의 거리, 볼트중심간 간격 등)이 거동에 영향을 미쳤기 때문인 것으로 추정된다. 전단보강재 간격별 휨실험 결과, 보강재 간격이 감소할수록 정모멘트에 대한 하중저항성능, 부모멘트에 대한 변위저항성능이 향상되는 것으로 확인되었다. 전단보강재 형상별 휨실험결과, U형 보강재 적용에 따른 정 부모멘트 저항성능 증가율은 약 2%~7% 로 낮았다. 따라서 대골형 파형강판 합성부재의 휨성능증가에는 파형강판의 강종, 전단보강재 간격, 보강철근의 특성이 주요한 영향을 미치는 것으로 판단된다.

소성전단힌지를 갖는 PC 모멘트 골조의 내진성능 (Seismic Performance of PC Moment Frame with Plastic Shear Hinge)

  • 임우영;홍성걸
    • 콘크리트학회논문집
    • /
    • 제27권4호
    • /
    • pp.353-362
    • /
    • 2015
  • 이 연구에서는 소성 전단힌지가 있는 PC 모멘트 프레임의 내진성능을 평가하기 위해 반복 하중실험을 수행하였다. 보의 중간 길이에 설치된 소성 전단 힌지는 PC 골조를 연결하는 역할을 하며, 두 개의 강판으로 구성된다. 각 강판에는 세 개의 전단연결고리가 존재한다. 세 개의 전단 연결고리는 PC 보의 전단강도의 50%, 75%, 그리고 100%에 해당하는 전단강도를 사용하여 설계되었다. 제안된 연결방식은 효율적인 에너지 소산 용량 및 우수한 구조적 성능을 보여주었다. 실험결과, 소성 전단 힌지는 보 전단강도의 100% 미만을 사용하여 설계하는 것이 합리적이라 판단된다.