• Title/Summary/Keyword: Molecular Image

Search Result 254, Processing Time 0.17 seconds

Design and Implementation of Bioluminescence Signal Analysis Tool

  • Jeong, Hye-Jin;Lee, Byeong-Il;Hwang, Hae-Gil;Song, Soo-Min;Min, Jung-Joon;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1580-1587
    • /
    • 2006
  • The term molecular imaging can be broadly defined as the in vivo characterization and measurement of biologic processes at the cellular and molecular level. Optical imaging that has highly reproducibility and repetition used in molecular imaging research. In the bioluminescence imaging, animals carrying the luciferase gene are imaged with a cooled CCD(Charge-Coupled Device) camera to pick up the small number of photons transmitted through tissues. Molecular imaging analysis will allow us to observe the incipience and progression of the disease. But hardware device for molecular imaging and software for molecular image analysis were dependent on imports. In this paper, we suggest image processing methods and designed software for bioluminescence signal analysis. And we demonstrated high correlation(r=0.99) between our software's photon counts and commercial software's photon counts. ROI function and processing functions were accomplished without error. This study have the importance of the development software for bioluminescence image processing and analysis. And this study built the foundations for creative development of analysis methods. We expected this study lead the development of image technology.

  • PDF

Fluorescence Molecular Imaging

  • Choi, Heung-Kook;Ntziachristos, Vasilis;Weissleder, Ralph
    • Proceedings of the KSMRM Conference
    • /
    • 2004.09a
    • /
    • pp.23-32
    • /
    • 2004
  • The chemotherapy sensitive Lewis lung carcinoma (LLC) and chemotherapy resistant Lewis lung carcinoma (CR-LLC) tumors concurrently implanted in mice, and compare these findings with histological macroscopic observations against 3D reconstruction of Fluorescence Molecular Tomography (FMT) preformed in vivo on the same animals. For the 3D image reconstruction we used 32 laser source images, a flat image and 3D surface rendering that confused for 3D Fluorescence Molecular Imaging (FMI). A minimum of ten tissue sections were analyzed per tumor for quantification of the TUNEL-positive cells, cell-associated Cy5.5-Annexin and vessel-associated Alexa Fluor-Lectin. These are useful apoptosis and angiogenesis markers, and they serve as validation experiments to data obtained in vivousing a Cy5.5-Annexin V conjugate injected intravenously in chemotherapy-treated animals carrying the tumors studied histologically. We detected higher levels of apoptosis and corresponding higher levels of Cy5.5 fluorescence in the LLC vs. the CR-LLC tumors according to tissue depth and these findings confirm that in vivo staining with the Cy5.5-Annexing conjugate correlates well with in vitro TUNEL staining and is consistent with the higher apoptotic index expected from the LLC line. There appeared to be 1.38% more apoptosis for LLC than CR-LLC. Consequently there is good correlation between the histology results and in vivo fluorescence-mediated optical imaging. In conclusion the apoptotic images of 3D FMI were validated by microscopic histological image analysis. This is a significant result for the continuous progress of fluorescence 3D imaging research.

  • PDF

Deep-Learning-Based Molecular Imaging Biomarkers: Toward Data-Driven Theranostics

  • Choi, Hongyoon
    • Progress in Medical Physics
    • /
    • v.30 no.2
    • /
    • pp.39-48
    • /
    • 2019
  • Deep learning has been applied to various medical data. In particular, current deep learning models exhibit remarkable performance at specific tasks, sometimes offering higher accuracy than that of experts for discriminating specific diseases from medical images. The current status of deep learning applications to molecular imaging can be divided into a few subtypes in terms of their purposes: differential diagnostic classification, enhancement of image acquisition, and image-based quantification. As functional and pathophysiologic information is key to molecular imaging, this review will emphasize the need for accurate biomarker acquisition by deep learning in molecular imaging. Furthermore, this review addresses practical issues that include clinical validation, data distribution, labeling issues, and harmonization to achieve clinically feasible deep learning models. Eventually, deep learning will enhance the role of theranostics, which aims at precision targeting of pathophysiology by maximizing molecular imaging functional information.

Feature values of DWT using MR general imaging and molecular imaging (DWT를 이용한 MR 일반영상과 분자영상 특징추출)

  • Pack, Dae-Sung;Choi, Gui-Rack;Han, Byung-Sung;Ahn, Byung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.409-414
    • /
    • 2012
  • This study acquired molecular lmaging using nano-contrast agents, and the general condition of the same image acquisition to analyze the difference between molecular imaging and general imaging, two images are converted into DWT (Discrete Wavelet Transform). Nano-contrast agent imaging using MRI and molecular imaging using PET study of molecular imaging technology mainstream. DWT analysis of the same lesions using MRI imaging and molecular imaging block lesions are present in the lesions, illustrating the value of a high-frequency feature both highly general imaging and molecular imaging could know that. The high frequency region of the feature extraction values appear higher molecular imaging.

Motion Correction in PET/CT Images (PET/CT 영상 움직임 보정)

  • Woo, Sang-Keun;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.172-180
    • /
    • 2008
  • PET/CT fused image with anatomical and functional information have improved medical diagnosis and interpretation. This fusion has resulted in more precise localization and characterization of sites of radio-tracer uptake. However, a motion during whole-body imaging has been recognized as a source of image quality degradation and reduced the quantitative accuracy of PET/CT study. The respiratory motion problem is more challenging in combined PET/CT imaging. In combined PET/CT, CT is used to localize tumors and to correct for attenuation in the PET images. An accurate spatial registration of PET and CT image sets is a prerequisite for accurate diagnosis and SUV measurement. Correcting for the spatial mismatch caused by motion represents a particular challenge for the requisite registration accuracy as a result of differences in PET/CT image. This paper provides a brief summary of the materials and methods involved in multiple investigations of the correction for respiratory motion in PET/CT imaging, with the goal of improving image quality and quantitative accuracy.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

The Rheological Behaviours for Ink Vehicle According to Molecular Weight of Rosin Modified Phenolic Resin (변성 페놀 수지의 분자량 변화에 따른 잉크 비히클의 물성 변화에 관한 연구)

  • Kim, Tae-Hwan;Kim, Sung-Bin;Lee, Kyu-Il
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.23 no.2
    • /
    • pp.1-14
    • /
    • 2005
  • Generally, printing inks are composed of pigment, vehicle and additive. Among others, the vehicle transfers the pigment to substrate and then binds it on the surface. So, rheological properties of the vehicle are an important factor which has influence on printability. Thus, in this study, rheology of the vehicle was investigated by using rotational rheometer according to molecular weight of resin. Also, emlusion rheology of water in oil type and its microstructure were examined with increasing the shear rate. Consequently, the following results were obtained: (1) By viscometric flow test, zero shear viscosity and shear thinning index of vehicle increased with increasing the molecular weight of resin. (2) By relaxation and creep test, relaxation time and retardation time of vehicle increased with increasing the molecular weight of resin. (3) By frequency sweep test, crossover point of vehicle increased with increasing the molecular weight of resin. (4) G' and G" of emlusions increased with increasing the molecular weight by amplitude sweep test. (5) The shape of water drop in emlusions was changed to the capillary tube.

  • PDF

The Rheological Properties of Printing Ink according to the Molecular Weight of Rosin Modified Phenol Resin (로진 변성 페놀 수지의 분자량 변화에 따른 인쇄 잉크의 유변학적 특성에 관한 연구)

  • Lee, Kyu-Il;Kim, Sung-Bin;Kim, Tae-Hwan
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.24 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The rheological characteristics of an ink relate to its performance on the press and to the printing quality such as ink stability, transfer characteristics, mottle, squash, misting, dot gain, and so on. For lithographic print, the emulsification of ink is an important factor to determine the product. And also the rheological characteristics of the emulsified ink should be investigated. Thus, in this study, the effects of the changing molecular weight of rosin modified phenolic resin on the water-pickup ratio of neat inks were studied. And then rheological properties of neat inks and emulsified inks with changing molecular weight of rosin modified phenolic resin were analyzed by using rotational rheometer.

  • PDF

A Study on the Color Reproduction of Halftone Image by used Factor N and Process Ink Characteristics (Factor N와 잉크특성을 고려한 망점화상의 색재현예측에 관한 연구)

  • 김성근
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.13-27
    • /
    • 1994
  • Litho printing ink vehicles based on rosin modified phenolic are faster drying, have better durability, are harder and glosser and have greater resistance to water than ones based on ester gums. Ink-Water balance and rheological properties are important in litho printing process. These physical properties is concerned with molecular weight of Resin to use vehicle. So this paper was studied about the effects of changing molecular weight of Rosin modified phenolic on surface tension, viscosity, pseudoplasticity and printablility of Litho Inks. The results were as follows. 1) The surface tension of model inks depended on the molecular weight of the resin : Dispersion componnent of ink increase but non dispersion component decrease as molecular weight of Resin increase. 2) Water pick-up of litho ink is more fast balance, using low molecular weight of Resin. 3) Viscosity, Yield value and Newtonian value of model inks increase as molecular weight of Resin increase. 4) The litho ink prepared with the modified phenolic of which molecular weight is about 20000 showed the highest printing density and gloss.

  • PDF

Pre- and Post-Treatment Imaging of Primary Central Nervous System Tumors in the Molecular and Genetic Era

  • Sung Soo Ahn;Soonmee Cha
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1858-1874
    • /
    • 2021
  • Recent advances in the molecular and genetic characterization of central nervous system (CNS) tumors have ushered in a new era of tumor classification, diagnosis, and prognostic assessment. In this emerging and rapidly evolving molecular genetic era, imaging plays a critical role in the preoperative diagnosis and surgical planning, molecular marker prediction, targeted treatment planning, and post-therapy assessment of CNS tumors. This review provides an overview of the current imaging methods relevant to the molecular genetic classification of CNS tumors. Specifically, we focused on 1) the correlates between imaging features and specific molecular genetic markers and 2) the post-therapy imaging used for therapeutic assessment.