• 제목/요약/키워드: Mold Transformer

검색결과 67건 처리시간 0.032초

변압기 권선 지지용 BMI 수지 복합재 제조 공정 개발 (Fabriation of BMI Resin Composite for High Speed Train Transformer)

  • 엄문광;김종훈;우재희;김세창
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.257-260
    • /
    • 2000
  • The composite composed of glass fabric and BMI resin was fabricated using resin transfer molding(RTM) process. it will be used as a supporting plate of transformer coil for high speed train. To develop a RTM process, permeability of preform was measured and resin properties like a viscosity and gellation time were checked. A resin pre-heating system and a mold system were also designed and developed. Using a vacuum-assisted RTM process, the composite supporting plate was successfully fabricated.

  • PDF

몰드형 건식 계기용 변압기 제작을 위한 수지 충진 해석 연구 (Numerical Analysis of Resin Filling Process for a Molded Dry-type Potential Transformer)

  • 김무선;장동욱;김승모
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.511-517
    • /
    • 2016
  • 철도 차량에 쓰이는 기존 유입식 형태의 계기용 변압기는 장치 내부에 절연유가 충진 된 형태이므로, 차량 운행 중에 내부 압력이 상승할 수 있는 가능성이 있으며. 그에 따른 폭발위험성이 존재한다. 따라서 폭발 방지를 위해 몰드형 건식 계기용 변압기를 개발 중에 있다. 몰드형 건식 계기용 변압기 개발시 주의 하여야 할 점은 몰드를 구성하는 절연용 에폭시 수지를 주입할 때 권선 코일이 감겨진 코어 주변에 기공이 없어야 한다는 것이다. 이는 몰드 내부의 기공에서 스파크 등의 발생 위험이 있기 때문이다. 몰드 내의 기공 발생 요인으로는, 수지 내에 미세 기공(micro void)이 잔재되어 있는 경우와, 성형 중 함침 구조물의 형태에 따라서 대형 기공(macro void)이 발생할 수 있는 점 등이다. 현재 개발 중인 코어는 변압기 성능 향상을 위해 중공(cavity)이 존재하는 형태이며 점도가 높은 에폭시 주입시 중공 내부에 대형 기공이 갇힐 위험이 있다. 따라서 이번 연구에서는, 몰드 내부에 발생할 수 있는 대형 기공의 형성 과정을 이해하고, 기공 형성 요인을 제거할 수 있는 방안으로, 개선된 성형 조건 적용시 기공 형성 결과를 확인하기 위해, 몰드 충진 과정을 VOF기법을 적용한 자유 표면 유동의 수치해석을 통하여 확인하였다.

전철 급전시스템의 22900/1200V 유입변압기 안전성 분석 (Safety Analysis and Safety Measures of 22900/1200V Oil Immersed Transformer at Power Supply System)

  • 이종수;이종우
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1335-1342
    • /
    • 2013
  • Subway is electrified railway system nowadays, in which liquid dielectric transformers have been widely used, though mold type transformers are replacing it. The transformers supplies large electric power and have innate hazards causing accidents under operation. A number of researcher have carried out on failures of it and have oriented to identify transformer's failure causes and how to maintain it healthy state. The transformer failures can cause serious accidents which can provoke economic loss and leads persons to kill. In this paper, we carried out a safety activity to reveal hazards and to estimate risk of subway liquid dielectric transformers using FMEA, HAZOP and What-if methods. In case of installing safety devices in oil immersed transformer, we tried to evaluate an effect on a subsystem's failure rate. We proposed how to design subsystem failure rate and safety device failure rates.

몰드변압기 진동신호의 FFT 및 시계열 계수 분석 (FFT and AR Coefficient Analysis of Vibration Signal in Mold Transformer)

  • 정용기;정종욱;김재철;곽희로
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.136-145
    • /
    • 1998
  • 본 논문에서는 몰드변압기 예방진단을 위해 정상상태와 비정상상태 몰드변압기의 진동신호의 FFT 및 시계열 분석에 관해 연구하였다. 실험올 위한 제어변수들로 공급전압, 부하전류 및 주위온도를 변화시키면서, 진동신호 크기, 주파수 스펙트럼 및 시계열 계수와 같은 측정변수들을 분석하였다. 제어변수 변화에 의한 진동선호는 권선표변과 철섬에 부착된 가속도센서로 측정되었으며, 이 신호들은 중폭기를 거쳐 데이터 수집장치에서 측정변수들로 계산되었다. 또한, 정 상상태 분석 후, 몰드변압기의 구조적 변형올 모의하였다. 비정상상태 진동신호는 정상상태와 같은 제어변수 변화 에 의해 측정되었다. 연구 결과, 정상상태와 비정상상태 진동신호는 수직진동신호와 수평진동신호를 비교하여 분석함으혹써 구별이 가능하였다.

  • PDF

몰드형 계기용 변압기의 소손원인 해석에 관한 연구 (A Study on the Deteriorated Cause Analysis of Mold Type Potential Transformer)

  • 최충석;김혁수;송길목;김형래;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1557-1559
    • /
    • 2000
  • In this paper, we intend to establish the judgement of electrical fire through analysis of PT(Potential Transformer) using the power installation. The columnar structure and the void generated by abrupt heat grew at the tenter of boundary-face on the metallurgical microscope analysis. The detection of OK lines was confirmed by EDX(Energy Dispersive X-ray spectroscopy) as melting and recombination due to the layer-short of the wiring. We found that the thermal-weight decrease occurred at 300$^{\circ}C$ in case of being the thermal-deterioration on the base of the result that analyzed the insulated-materials by using TGA, and the thermal reaction limited-value of PT insulator was about 300$^{\circ}C$ on the DSC curve. As this analysis, we confirmed what the layer-short appeared in the wiring of PT.

  • PDF

전자계해석을 이용한 고효율 몰드변압기 손실 평가기술 연구 (A study on Loss Evaluation Technology of High Efficiency Mold Transformers using Electromagnetic Field Simulation)

  • 정상훈;이곤;최명준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.774-775
    • /
    • 2015
  • In this paper, a series of electromagnetic analyses carried out for a high efficiency 22.9/0.38kV mold transformer are presented. The simulations were performed in order to calculate the losses which eventually verify the performance(efficiency) of the designed product. Here, losses include core loss, stray losses of non-current carrying metallic structural parts(core plate and clamp), ohmic loss and eddy current loss of current carrying metallic parts(busbars, leads, terminals and windings). The obtained results of the simulations were compared to the test results and showed high level of accuracy. The loss evaluation technology will allow designers avoid any potential over-design or under-design of the high efficiency products, reducing the manufacture cost and development period compared to the conventional experience-based design procedures.

  • PDF

50[kVA] 몰드변압기 권선부의 열전달 특성 해석 (Analysis on Thermal Transfer Characteristics of 50 kVA Mold-Transformer)

  • 이현진;정중일;허창수;조한구
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.47-54
    • /
    • 2002
  • 본 논문은 단상 50[kVA] 몰드변압기 권선부의 열전달 특성에 대한 연구 결과이다. 1차 권선의 열전도도는 권선을 이루고 있는 물질 비 즉, 1차 권선의 절연을 담당하는 다량의 에폭시 수지와 그에 비해 소량의 구리 도선을 고려하여 결정하였다. 반면에 2차 권선의 경우 구성 성분은 다량의 구리도선과 절연을 담당하는 소량의 에폭시 수지로 되어 있다. 2차 권선 열전도도는 질량 비로서 결정될 수 없기 때문에 2차 권선의 열전도도값은 시작품의 측정 최고온도와 FEM을 이용한 분석결과를 비교하여 결정하였다. 각 권선부의 물리적 특징을 고려하여 상용 프로그램을 통해 시뮬레이션 모델을 만들었다. 본 연구결과를 바탕으로 몰드변압기 권선부에 Hole이 존재할 때와 안할 때 각각에 대해 주위온도·풍속변화에 따른 최고온도 변화를 고찰하였다.

2MVA 몰드 변압기의 정전용량 계산 (An Analysis of Capacitance for a 2 MVA Mold Transformer)

  • 장형택;정현구;김영배;우성현;신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.674_675
    • /
    • 2009
  • 수치해석을 사용하여 2MVA 몰드 변압기의 정전용량을 시뮬레이션(FLUX 2D)하고 계산하였다. 산출한 정전 용량 값을 변압기 모델링 회로에 적용하여 switching surge 등 이상전압이 인가되었을 때 변압기 내부에 있는 권선들의 전압분포를 예상하고 절연설계에 적용 할 수 있음을 보였다.

  • PDF

에폭시 몰드형 PT의 절연특성 개선 (Improvement on Property of Insulation in PT of Epoxy Mold Type)

  • 송재주;김성홍;최명호;이재;임성훈;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.67-71
    • /
    • 2001
  • PT of epoxy mold type have tendency to occur dielectric breakdown in high voltage system. These are using for measurement of voltage or protection of system and application voltage is 25.8kV. Therefore, for improving a lots of problems like as partial discharge, we had analyze on the destroyed Epoxy molded type PT and processing of production. As a results, we concluded that the reason of dielectric breakdown was defect of processing and degradation of insulation by electrical stress. In this work, We presented a method of solution in processing of production. which is reduction of the PO which was occurred at the insulation material. so we must many try to remove faults, these problems are mainly to winding methods of 1st coil. the other side, Reformation of 1st coil improved property of PD and we could prove it with experiments.

  • PDF

초고압 현수애자의 Pin 형상에 따른 응력해석 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;박기호;한세원;윤문수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.155-157
    • /
    • 2001
  • Various types suspension insulators made of toughness glass or porcelain are used in the power transmission. And, Insulators are continually subject to mechanical and electrical stresses which depend on the characteristics of the line. The main factor that influence the increase in reliability of insulators. In operation is the capacity of the design to withstand the certain load over a long time, the mechanical strength of the insulators. This paper describes the results of a study on the stress analysis of suspension insulator based on the finite element analysis using NASTRAN. And, the mechanical strength was evaluated through such as kinds of pin type.

  • PDF