• Title/Summary/Keyword: Mold Analysis

Search Result 1,206, Processing Time 0.027 seconds

Physicochemical Characteristics and Microbiological Distribution of Korean Traditional Meju of Various Region (지역별 시판 전통메주의 이화학적 및 미생물 분포 특성)

  • Shin, Dong-Sun;Han, Sang Ik;Choi, In Duck;Lee, Seuk Ki;Park, Ji Young;Kim, Nam Geol;Choi, Hye Sun
    • The Korean Journal of Food And Nutrition
    • /
    • v.31 no.5
    • /
    • pp.712-719
    • /
    • 2018
  • This study was carried out to obtain basic data on Korean traditional Meju collected from 18 regions (TM1~TM18) in Korea and to define and control quality. The shape of Meju was mostly rectangular and the weight was 0.84~2.04 kg. The physicochemical analysis showed: pH, 5.31~8.21; total acidity, 0.91~2.74%; moisture content, 4.79~42.16%; and soluble protein content, 41.37~23.48%. Hunter color values for L (lightness), a (redness), and b (yellowness) ranged from 39.07~67.92, 3.57~8.87, and 7.48~20.67, respectively. The amino nitrogen contents of all samples were in the range of 257.29 to 839.58 mg% and TM13 showed the highest content (839.58 mg%). Total viable cells, yeast and mold counts of Meju were 8.43~5.91 log CFU/g, 2.48~5.19 log CFU/g, and 3.42~7.48 log CFU/g, respectively. Based on the results, it is proposed that quality standards and management of Meju fermentation conditions and information about different varieties of soybeans used should be made available.

A Study on the Creep Behavior of AlSl 420F Stainless Steel (AlSl 420F 스테인리스강의 Creep 거동)

  • Park, Yong Gwon;Yoon, Byoung Joo;Choi, Jae Ha
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.6
    • /
    • pp.383-390
    • /
    • 2000
  • The static creep behaviour of AlSl 420F stainless steel was investigated over the temperature range of $540{\sim}585^{\circ}C$ and the stress range of $13{\sim}19kg/mm^2$ (127.4~186.2MPa). Constant stress creep tests were carried out in the experiment. Measured stress exponent, n, for the creep deformation of the alloy under the given conditions was found to vary at the range of 9.59, 9.15, 8.78, and 8.53 for the temperature of 540, 555, 570, and $585^{\circ}C$ respectively. The activation energy, Qc, for the creep deformation was 106.42, 102.58,97.81, and 94.58 kcal/mole for the stress of 13, 15, 17, and $19kg/mm^2$, respectively. Lason-Miller parameter, P, for the crept specimens for AlSl 420F stainless steel was measured as $P=T(log\;t_T+21)$. The empirical static creep rate obtained by the regression analysis was as follows. $${\varepsilon}={\exp}[(3.79{\times}10^{-2}{\sigma}+2.722)T-3.0747{\sigma}+28.109]{\times}{\sigma}^{(-2.367{\times}10^{-2}T+22.33)}{\exp}\left[-\frac{(-2.015{\sigma}+132.580){\times}10^3}{RT}\right]$$ The failure plane were observed, intergranular fracture was dominated by r (round) type crack over the experimental range.

  • PDF

Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time

  • Lee, Jung-Won;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.126-131
    • /
    • 2011
  • PURPOSE. The aim of this in vitro study was to examine the curing efficiency of various resin-based materials polymerized through ceramic restorations with 3 different thicknesses. Curing efficiency was evaluated by determining the surface microhardness (VHN) of the resin specimens. MATERIALS AND METHODS. Four kinds of resin materials were used. Z350 (3M ESPE $Filtek^{TM}$ Z350: A2 Shade), Z250 (3M ESPE $Filtek^{TM}$ Z250: A2 Shade) and $Variolink^{(R)}$ II (VL: Ivoclar vivadent, base: transparent) either with or without a self-curing catalyst (VLC: Ivoclar vivadent, catalyst: low viscosity/transparent) were filled into the silicone mold (10 mm diameter, 1 mm thick). They were cured through ceramic discs (IPS e.max Press MO-0 ingot ivoclar vivadent, 10 mm diameter, 0.5, 1 and 2 mm thicknesses) by LED light-curing units for 20 and 40 seconds. Vicker's microhardness numbers (VHNs) were measured on the bottom surfaces by a microhardness tester. Data were analyzed using a 3-way analysis of variance (ANOVA) at a significance level of 0.05. RESULTS. The thickness of ceramic disc increased, the VHNs of all four resin types were decreased (P<.05). The mean VHN values of the resins light cured for 40 seconds were significantly higher than that of LED for 20 seconds in all four resin materials (P<.05). VLC showed significantly higher VHN values than VL regardless of other conditions (P<.05). Z350 and Z250 showed higher values than VL or VLC (P<.01). CONCLUSION. Thinner ceramic disc with increased curing time resulted higher VHN values of all resin materials. The use of a catalyst produced a greater hardness with all polymerization methods. Restorative resin materials (Z350, Z250) showed higher VHN values than resin cement materials (VL, VLC).

A STUDY ON THE FRACTURE TOUGHNESS OF DENTAL COMPOSITE RESINS (치과용 복합레진의 파괴인성에 관한 실험적 연구)

  • Park, Jin-Hoon;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.17-33
    • /
    • 1990
  • The purpose of this study was to evaluate the fracture toughness of dental composite resins and to investigate the filler factor affecting the fracture behaviour on which the degree of fracture toughness depends. Six kinds of commercially available composite resin;, including two of each macrofilled, microfilled, and hybrid type were used for this study, The plane strain fracture toughness ($K_{10}$) was determined by three-point bending test using the single edge notch specimen according to the ASTM-E399. The specimens were fabricated with visible light curing or self curing of each composite resin previously inserted into a metal mold, and three-point bending test was conducted with cross-head speed of 0.1mm/min following a day's storage of the specimens in $37^{\circ}C$ distilled water. The filler volume fractions were determined by the standard ashing test according to the ISO-4049. Acoustic Emission(AE), a nondestructive testing method detecting the elastic wave released from the localized sources In material under a certain stress, was detected during three-point bending test and its analyzed data was compared with, canning electron fractographs of each specimen. The results were as follows : 1. The filler content of composite resin material was found to be highest in the hybrid type followed by the macrofilled type, and the microfilled type. 2. It was found that the value of plane strain fracture toughness of composite resin material was in the range from 0.69 MPa$\sqrt{m}$ to 1 46 MPa$\sqrt{m}$ and highest In the macrofilled type followed by the hybrid type, and the microfilled type. 3. The consequence of Acoustic Emission analysis revealed that the plane strain fracture toughness increased according as the count of Acoustic Emission events increased. 4. The higher the plane strain fracture toughness became, the higher degree of surface roughness and irregularity the fractographs demonstrated.

  • PDF

SiC Contaminations in Polycrystalline-Silicon Wafer Directly Grown from Si Melt for Photovoltaic Applications (실리콘 용탕으로부터 직접 제조된 태양광용 다결정 실리콘의 SiC 오염 연구)

  • Lee, Ye-Neung;Jang, Bo-Yun;Lee, Jin-Seok;Kim, Joon-Soo;Ahn, Young-Soo;Yoon, Woo-Young
    • Journal of Korea Foundry Society
    • /
    • v.33 no.2
    • /
    • pp.69-74
    • /
    • 2013
  • Silicon (Si) wafer was grown by using direct growth from Si melt and contaminations of wafer during the process were investigated. In our process, BN was coated inside of all graphite parts including crucible in system to prevent carbon contamination. In addition, coated BN layer enhance the wettability, which ensures the favorable shape of grown wafer by proper flow of Si melt in casting mold. As a result, polycrystalline silicon wafer with dimension of $156{\times}156$ mm and thickness of $300{\pm}20$ um was successively obtained. There were, however, severe contaminations such as BN and SiC on surface of the as-grown wafer. While BN powders were easily removed by brushing surface, SiC could not be eliminated. As a result of BN analysis, C source for SiC was from binder contained in BN slurry. Therefore, to eliminate those C sources, additional flushing process was carried out before Si was melted. By adding 3-times flushing processes, SiC was not detected on the surface of as-grown Si wafer. Polycrystalline Si wafer directly grown from Si melt in this study can be applied for the cost-effective Si solar cells.

Relationships Between Pathogenicty and Activities of Polygalacturonase, Laccase, and ${\beta}$-Glucosidase Produced by Botrytis cinerea (Botrytis cinerea 균주들이 생산하는 Polygalacturonase, Laccase, ${\beta}$-glucosidase의 균주 간 화성 및 병원성과의 상관관계)

  • Kim, Jong-Jin;Kim, Jae-Won;Lee, Chang-Won;Chung, Young-Ryun
    • Korean Journal Plant Pathology
    • /
    • v.13 no.4
    • /
    • pp.225-231
    • /
    • 1997
  • Activities of polygalacturonase, laccase, and intra- and extra-cellular $\beta$-glucosidase produced by 20 Botrytis cinerea isolates in liquid culture media containing cucumber cell was as a carbon source were measured and their relationships to the pathogenicity were analyzed. No significant correlations between these enzyme activities and the pathogenicity of B. cinerea were found. Mycelial growth rate on Bayendamm media, however, was higthly correlated with the pathogenicity (r=0.522) anong these isolates. Immuno-blot analysis of the culture filtrate using antibody against against exo-polygalacturonase revealed that only one band with molecular weight of 66 kDa was detected amone 34 tested isolates. It appears that these enzymes may not be primary factors in dermining the pathogenicity of B. cinerea.

  • PDF

A Study on the Tool Wear and Prediction of CBN, Poly Crystal and Single Crystal Diamond Tools in Cutting of Nickel (니켈절삭시 CBN, 소결 및 단결정 다이아몬드 공구의 마멸과 예측에 관한 연구)

  • 성기석;김정두
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.120-130
    • /
    • 1993
  • Generally, the machinability of materials that have a good mechanical properties is poor. For materials having a high strength, high toughness, high strength in high temperature and wear resistance, it is difficult to remove a chip from work materials. These properties are well shown in a Nickel, so this metal is used in machine materials, semi-conductor industry, metal mold and optical fields etc. But it is limitted in use because of high cost and poor machinability. In this study, the cutting of pure Nickel was conducted to examine wear of CBN, poly crystal diamond (PCD) and single crystal diamond (SCD) tools. From the result, the CBN tool is superior to poly crystal diamond tools or single crystal diamond tools in terms of tool wear and tool wear is predictable from experimental data base.

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

Nanocrystallization of Cu-Based Bulk Glassy Alloys upon Annealing

  • Pengjun, Cao;Dong, Jiling;Haidong, Wu;Peigeng, Fan;Anruo, Zhou
    • Applied Microscopy
    • /
    • v.46 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • The Cu-based bulk glassy alloys in Cu-Zr-Ti-Ni systems were prepared by means of copper mold casting. The Cu-based bulk glassy alloys samples were tested by X-ray diffractomer (XRD), differential scanning calorimeter, scanning electron microscopy (SEM), Instron testing machine and Vickers hardness instruments. The result indicated that the prepared Cu-Zr-Ti-Ni alloys were bulk glassy alloys. The temperature interval of supercooled liquid region (${\Delta}T_x$) was about 45.48 to 70.98 K for the Cu-Zr-Ti-Ni alloy. The Vickers hardness was up to 565 HV for the $Cu_{50}Zr_{25}Ti_{15}Ni_{10}$ bulk glassy alloy. The $Cu_{50}Zr_{25}Ti_{15}Ni_{10}$ bulk glassy alloys were annealed in order to obtain nanocrystals. The results showed that the Vickers hardness was raise up to 630 HV from 565 HV. As shown in XRD results, the amorphous alloys changed to nanocrystals, which were $Cu_8Zr_3$, $Cu_3Ti_2$ and CuZr, improved the hardness. The SEM analysis showed that the compression fractured morphology of amorphous alloys was brittle fracture, and the fracture morphology after annealing was ductile fracture. This proved that annealing of amorphous to nanocrystals can improve the plasticity and toughness of amorphous alloys.

Influence of mechanical properties of ultra-dental stone on setting methods (경화방법이 치과용 경석고의 기계적 특성에 미치는 영향)

  • Im, Yong-Woon;Hwang, Seong-Sig;Kim, Sa-Hak;Choi, Je-Woo;Jeong, Su-ha;Kim, Si-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.33-40
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the influence of mechanical properties of various ultra-dental stone by setting methods. Methods: 240 cylinder specimens($10mm{\times}20mm$) were prepared from three ultra-dental stones(Gemma, Die keen and Fuji rock; n = 80) in accordance with the manufacturers' recommendations. Half of the specimens of each stone(n = 40) were dried in open air within a room temperature; the other half(n = 40) underwent in a silicone rubber mold in open air for 30 minutes and then were dried in a microwave oven for 10 minutes to 600W. Compressive strength(CS), compressive modulus(CM) and diametral tensile strength(DTS) conducted until fracture using Instron 5966 at each of the following periods: 1 and 24 hours from mixing. One-way analysis of variance and Scheffe's post hoc test were performed for statistical comparisons at a significance level of P<.05. Results: The CS and CM values in all dental stone indicated highest after 24h(54.25 MPa < ) than the values for specimens dried in microwave method. The DTS values revealed the highest microwave method. However, in 24h, FJ(Fu-ji rock) and GM(Gemma) had lower mechanical properties than air. Conclusion : Within the limitations of this study, CS did not influence by microwave method but DTS affected according to the setting.