• Title/Summary/Keyword: Moire Topography

Search Result 54, Processing Time 0.023 seconds

A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image (Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구)

  • Lee Eun-Kyoung;Yu Seung-Hyun;Lee Su-Kyung;Kang Sung-Ho;Han Jong-Min;Chong Myong-Soo;Chun Eun-Joo;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.2
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF

A Study on the Drapability and the Shape of the Flare Skirt -by $moir\'{e}$ Topography method- (Flare Skirt의 Drape성과 착장형태파악에 관한 연구 -$Moir\'{e}$ Photograph법을 중심으로-)

  • Kim Hae-kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.1
    • /
    • pp.38-47
    • /
    • 1991
  • The purpose of this study was to investigate the effect of physical properties and grain line of fabrics on the drape properties of the flare skirt. Horizontal section overlap map was obtained by three dimensional Moire Topography, It was concluded drapability of the skirt obtained by the map can be used to determine the ease of the skirt. Grain line such as bias and lengthwise direction showed the difference of quality of the drape at the hem line; skirt made by bias direction showed evenly distributed flare and effective for the aesthetic point view. No difference was observed between cotton and polyester fabrics probably due to the similar characteristics of the fabrics.

  • PDF

The Efficacy of Korean Herbal Cosmetics for Facial Skin Elasticity (한방화장품이 안면부의 탄력 개선에 미치는 영향)

  • Kim, Min-Hee;Yun, Young-Hee;Cho, Ga-Young;Choi, In-Hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.25 no.3
    • /
    • pp.150-159
    • /
    • 2012
  • Objective : The purpose of this study was to evaluate the effect of korean herbal cosmetics for facial skin elasticity. Methods : We recruited patients and divided them to cosmetics group and control group randomly. We provided korean herbal cosmetics to cosmetics group and subjects in cosmetics group applied the provided cosmetics for 4 weeks. Control group waited and applied cosmetics that had previously used for 4 weeks. We assessed all subjects in 0 week, 2 weeks and 4 weeks. Primary assessment instrument was moire topography photo scale. Second assessment instrument was skin moisture, oiliness and elasticity which assessed with skintouch system v1.0, detox/regeneration questionnaire score and self-evaluating facial wrinkle/looseness score. Result : Moire topography photo scale improved in cosmetics group than control group significantly. Skin moisture and elasticity assessed with skintouch system improved in cosmetics group than control group significantly while skin oiliness assessed with skintouch system have not improved significantly. Detox/regeneration questionnaire score and self-evaluating facial wrinkle/looseness score improved in cosmetics group than control group significantly. Conclusion : Korean herbal cosmetics application might be effective method for facial skin elasticity.

Assessment of the Breast-Firmming Effects of a Cosmetic Preparation with Moir$\acute{e}$ Tophography in Combination with 2D and 3D Digital Image Analyses (2D 및 3D 디지털 이미지 분석과 함께 Moir$\acute{e}$ Tophography 분석을 이용한 화장품의 가슴 탄력개선 효과 평가)

  • Seo, Young Kyoung;Yoo, Mi Ae;Ryu, Ja Hyun;Kim, So Jeong;Cho, Seong A;Nam, Gae Won;Cho, Jun-Cheol;Boo, Yong Chool;Koh, Jae-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • Cosmetic products which might augment the breast have attracted an attention and objective methods for the evaluation of such products are in high demand. This study was conducted to establish a method for assessing the breast-firmming effects of cosmetics. This study included a total of 30 healthy Korean females aged 20-50 years. A cosmetic product was applied by massaging it onto the breast twice a day for 8 weeks. Measurement of breast girth with a tape ruler, 2D and 3D digital image analyses, and Moir$\acute{e}$ topographic analysis were performed before and following the treatment. The application of a cosmetic onto the breast significantly increased breast girth at 2, 4 and 8 weeks without a significant change in underbreast girth, implicating the breast might be augmented. The 2D image analysis indicated that the arc length of the breast which represents the surface distance from the nipple to the periphery of the under-breast was significantly increased at 2, 4 and 8 weeks. The height of the breast which represents the perpendicular distance from the nipple to the periphery of the under-breast was also increased significantly at 4 and 8 weeks. The 3D image analysis of body surface also demonstrated a significant increase of breast volume at 2, 4 and 8 weeks. Moir$\acute{e}$ topographic analysis indicated that breast sagging was significantly reduced at 2, 4 and 8 weeks. The results of this study suggest that Moir$\acute{e}$ topography in combination with 2D and 3D digital image analyses may be useful for evaluating the breast-augmenting effects of cosmetics.

System Design and Camera Calibration of Slit Beam Projection for Maximum Measuring Accuracy (슬릿광 3차원 형상측정에서 측정분해능 최적화를 위한 시스템설계 및 카메라보정)

  • 박현구;김명철;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1182-1191
    • /
    • 1994
  • This paper presents an enhanced method of slit beam projection intended for the rapid measurement of 3-dimensional surface profiles of dies and molds. Special emphasis is given to optimizing the design of optical system so that the measuring accuracy can be maximized by adopting two-plane camera calibration together with sub-pixel image processing techniques. Finally, several measurement examples are discussed to demonstrate that an actual measuring accuracy of $\pm$ 0.2 mm can be achieved over the measuring range of 500 mm{\times}300mm{\times}200mm$.

The Inspection of Press Forming Product Through Application of Reverse Engineering System (역설계 시스템 적용을 통한 프레스 성형물 검사)

  • Kim, Min-Joo;Kim, Soo-Yong;Lee, Seung-Soo;Chan, Jeon-Eon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1276-1283
    • /
    • 2004
  • This study is an inspection of press forming product and mould using reverse engineering system. The inspection process on production field involves a lot of errors because of the hand-work so we focussed on improving the measured precision through performing the effective inspection using 3D non-contact scanner. By so doing that, we improved the precision of press forming product by analyzing the cause following the inspection result. Through the inspection, we applied it to the reverse engineering and we could improve the inspection process.

Development of Dress Form for the Construction of Middle-aged Women's Clothing (중년여성 체형특성에 따른 인대모형설계)

  • 김순자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.2
    • /
    • pp.430-441
    • /
    • 1997
  • Journal of the Korean Society of Clothing and Textiles Vol. 21, No. 2 (1997) p. 430∼441 Clothing fitness is strongly required in the apparel industry, and draping is an effective tool to increase fitness to the wearers. A more sophisticated and systematic information of the somatotype, accordingly, is necessary for better dress form design. This study was performed to provide fundamental data on middle-aged women's somatotypes for dress form designers by classifying the torso somatotype and analyzing the characteristics of their somatotype. The subjects were directly measured anthropometrically and indirectly analyzed photo- graphically. Data were analyzed by factor analysis, cluster analysis and analysis of variance. On the basis of the cluster analysis, using 7 factors cores the subjects were classified into four groups and four dress forms for middle-aged women were constructed. 8y the analysis of moire topography of proposed dress forms that were constructed according to the characteristics and silhouettes of front and lateral views for each somatotype of subjects, three-dimensional characteristics of somatotype and overlapped crosssection diagrams were analyzed.

  • PDF

2중파장 영사식 무아레의 N-Buckets 알고리즘 오차비교에 관한 실험적 연구

  • 유원재;박낙규;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.181-181
    • /
    • 2004
  • 3 차원 형상측정기술(3-D Profile Measurement Method)은 가공품의 치수검사 및 형상측정 등의 공학분야뿐만 아니라 최근에는 의류산업 및 의학산업은 물론 오락산업의 가상현실 구현 등 여러 분야로 점차 사용이 확대되고 있다. 이러한 요구를 만족시킬 수 있는 광학을 바탕으로 한 비접촉 3 차원 형상측정방법(Non-contacting 3-D Profile Measuring Method)은 고속, 고정밀도 측정이 가능하기 때문에 활발히 연구되고 있다. 광학을 이용한 대표적인 3 차원 비접촉 측정방법의 하나인 영사식 무아레는 그림자식 무아레의 단점인 격자의 크기가 측정물체보다 커야 한다는 점과 측정물체와 격자사이의 거리 제한 문제를 해결하였으며, 위상이동법을 사용함으로서, 무아레 무늬 형태의 영향을 받지 않고 측정이 가능해졌다.(중략)

  • PDF

The Inspection of Press Forming Product of backward lamp parts at automobile through Application of Reverse Engineering System (역설계 시스템 적용을 통한 자동차 후방 램프부의 프레스 성형물 검사)

  • Kim S.Y.;Kim T.H.;Kim M.J.;Lee S.S.;Jeon E.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.419-422
    • /
    • 2005
  • This study is an inspection of press forming product and mould using reverse engineering system. The inspection process on production field involves a lot of errors because of the hand-work so we focussed on improving the measured precision through performing the effective inspection using 3D non-contact scanner. By so doing that, we improved the precision of press forming product by analyzing the cause fellowing the inspection result. Through the inspection, we applied it to the reverse engineering and we could improve the inspection process.

  • PDF

The Inspection of Press Forming Product of forward conner parts at automobile through Application of Reverse Engineering System (역설계 시스템 적용을 통한 자동차 전방 모서리부의 프레스 성형물 검사)

  • Han M.S.;Park J.D.;Kim M.J.;Lee S.S.;Jeon E.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.962-965
    • /
    • 2005
  • This study is an inspection of press forming product and mould using reverse engineering system. The inspection process on production field involves a lot of errors because of the hand-work so we focussed on improving the measured precision through performing the effective inspection using 3D non-contact scanner. By so doing that, we improved the precision of press forming product by analyzing the cause following the inspection result. Through the inspection, we applied it to the reverse engineering and we could improve the inspection process.

  • PDF