• Title/Summary/Keyword: Moire Measurement

Search Result 98, Processing Time 0.03 seconds

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 김도훈;유원재;박낙규;강영준
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.255-259
    • /
    • 2003
  • Moire topography method isa well-known non-contacting 3-D measurement method as afast non-contact test for three-dimension shape measuring method. Recently, it's important to study the automatic three-dimension measurement by moire topography because it is frequently applied to the reverse engineering , the medical , the entertainment fields. Three-dimension measurement using projection of moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, the classical moire method is computerized-so called digital moire when a virtual grating pattern is projected on a surface, the captured image by the CCD camera has three-dimension information of the objects. The moire image can be obtained through a simple image processing and a reference grating pattern. and it provides similar results without physical grating pattern. digital projection moire topography turn out to be very effective for the three-dimension measurement of objects. Using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the four-three step algorithm method instead of the same step in the phase shifting of different pitch.

  • PDF

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 유원재;김도훈;안재웅;강영준;노형민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF

A Study on the Virtual Grating Projection Moire Topography for the Shape Measurement of Human Face (인체형상 측정을 위한 가상격자 영사식 무아레 방법에 관한 연구)

  • 유원재;최정표;안중근;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.49-52
    • /
    • 2001
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topogrphy is very attractive because of it s high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the $2\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi$-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

A Study on Projective Calibration for Arbitrary Display Surface using Digital Moire Method. (Digital Moire를 이용한 임의의 영사면에 대한 투영보정에 관한 연구)

  • 유원재;김도훈;강영준;백성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.292-295
    • /
    • 2003
  • Moire topography method is a well-known non-contacting 3-D measurement method. the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this study, digital two-wavelength phase shilling moire is applied to the entertainment fields. recently. as promoting the growth of the VR-Game, display devices which attract public attention such as HMD or Projector are being appeared in order to deliver effectively the absorption sense. this study realized the Auto-calibrating system for arbitrary display surface using digital moire method which satisfied the shape measurement of display surface and the request of FOV(Field of View) output. also when large screen wasn't prepared, this auto-calibrating system was applied to enjoy games or movies at home with a projector and walls

  • PDF

Measurement of three dimensional shapes using phase-shifting shadow moire method (위상 이동 그림자 무아레 방법을 이용한 3차원 형상의 측정)

  • 강영준
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.4
    • /
    • pp.39-45
    • /
    • 1997
  • Shadow moire topography has been used as a noncontact method for measuring the 3-D shapes of objects. The moire fringes are results from the superposition of a master grating and its shadow projected on the surface of an object. But in case of the classical shadow moire method, in general, the resolution is a few tenths of millimeter. It is difficult to use a phase -shifting method in shadow moire because it is impossible to obtain uniform phase shifts on the whole field. But in this study , We introduce a phase-shifting method to improve the resolution of the classical shadow moire method. This method is based on the fact that if the depth of object is much less than the distance between the observer and the master grating, the phase shifts are almost uniform on the whole field area. Finally, we applied this new phase-shifting method to the measurement of the 3-D shape of a coin.

  • PDF

Measurement of three dimensional object shape by means of the phase-shifting shadow moire (위상이동 그림자 무아레법을 이용한 3차원 물체의 형상측정)

  • 유원재;노경완;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.96-100
    • /
    • 1997
  • The shadow moire is one of the optical techniques which is able to give contour lines of an object with respect to a master grating plane. The moire patterns are issued from the superposition of a master grating and its shadow projected on the surface of an object. In case of the classical shadow moire method, the sensitivity was a few tenths millimeters. generally, it is difficult to use a phase shift method in shadow moire because it is impossible to obtain uniform phase shifts on the whole field. But in this study we use the fact that if the depth of object is much less than the distance between the observer and the master grating, and the object is displaced perpendicularly to the grating plane, phase shifts are almost uniform. Finally we obtained a better resolution by using a phase shift procedure and applied the phase shifting shadow moire to three dimensional shape measurement.

  • PDF

Improvement of accuracy of surface measurement in the phase-shifting shadow moire method (위상이동 그림자 무아레방법에서 형상측정 정확도의 개선)

  • 유원재;강영준;권기용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.402-406
    • /
    • 1995
  • The shadow moire is one the optical techniques which able to give contour lines of an object with respect to a master grating plane. The moire patterns are issued from the superposition of a grating and its shadow projected on the surface of an object. But in the conventional shadow moire method the reference grating and deformed grating are mutually dependent, it is impossible to obtain uniform phase shifts on the whole field by moving the reference grating. Here we propose ane trial to apply phase shifting to conventional shadow moire. When, in the conventional arrangement, Phase-shifting that is sctually constant regardless of fringe orders is achieved by moving the grating and the light source. Finally we obtained a better result by using this procedure and applied the phase shifting shadow moire to three dimensional measurement.

  • PDF

A Study on the Improvement of Accuracy of Surface Measurement in the Phase-Shifting Shadow Moir$\'{e}$ Method (위상이동 그림자 무아레방법을 이용한 형상측정법의 정확도 개선에 관한 연구)

  • 강영준;유원재;권용기
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.96-102
    • /
    • 1998
  • In this study, the theory and application of phase-shifting shadow moire topography is focused on the non-contact measurement of object surfaces for practical use in the field of production engineering. Shadow moire topography has been studied during last few decades in the area of the optical physics, and now its mathmatical theory has been established. Generally, in case of the classical shadow moire topography, the sensitivity is a few tenths of millimeter in best cases. Here we tried the application of phase-shifting method to the conventional shadow moire topography. But the reference grating and the deformed grating are mutually dependent because it is impossible to obtain uniform phase shifts on the whole Held. Therefore it is difficult to use a phase-shifting method in shadow moire topography. However, it was shown that constant phase-shifting was able to be measured by moving both the grating and light source. Finally we obtained a better result by using this procedure and applied the phase-shifting shadow moire to three dimensional object measurement.

  • PDF

A study on 3-D shape measurement for the composition of human bust (인체흉상 합성을 위한 3차원 형상 측정에 관한 연구)

  • 안중근;강영준;최정표;유원재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.220-223
    • /
    • 1997
  • Moire topography method is a well-known non-contacting 3-D measuement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topography is very attractive because of it's high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the 2x-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the 2x-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

A Study on the Measurement of the Breast Shape on Living Body by Using a PMP Moire Method (가슴형상 측정을 위한 PMP Moire 방법 활용)

  • Lee, Ga-Na;Yuk, Keun-Cheol;Kim, Byeong-Mee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.11 no.2
    • /
    • pp.11-21
    • /
    • 2009
  • Recently, as custom-made demand about female underwear is increased, securing of a various dimension system is urgent, and satisfaction of each customer cannot be heightened with established dimensions. If we could measure shape of a living body with a fast and simple method, the custom-made demand of customers could be satisfied in the underwear as well as a clothing industry by using the method. One of the alternatives is shape measurement of the living body by a Moire fringe method. If we put a grating in front of an object to be measured and illuminate light, a Moire fringe with contour line shape is generated in the object, so we can conveniently measure object shape without touching directly by using the pattern. The Moire fringe and three-dimensional shape of the breast of the living body was acquired by a PMP method using a polygon mirror, and height and bottom width of the breast of the living body were measured by using obtained data in this study. Data of breast shape measurement through a mannequin was collected in a previous step as basic material for measuring the breast shape measurement of the living body. Three women in the twenties were selected as one of methods for measuring breast shape of a woman. As a result of the breast shape measurement of a living body A, it was measured that height of the breast was about 67.24mm and the bottom width was $13781.60mm^2$. This study is expected to contribute for collecting basic data of a female underwear industry and establishing a specification of a dimension system.

  • PDF