• Title/Summary/Keyword: Mohr-Coulomb 모델

Search Result 70, Processing Time 0.021 seconds

The Earth Pressure on the Effect of Surcharge Load at the Narrowly Backfilled Soil (좁은 공간 되메움 지반에서의 상재하 영향에 의한 토압)

  • 문창열;이종규
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.165-180
    • /
    • 1997
  • The structure such as underground external walls of buildings, conduit and box culvert supports the surcharge loads (point, strip and line loads) . The vertical and horizontal stresses in a soil mass depend on the backfill width and wall friction, etc. The investigations described in this paper is designed to identify the magnitude and the distributions of the lateral and vertical pressure which is occurred by the narrowly backfilled soil in an open cut by the surcharge loads. For these purposes, model tests were performed for various width of backfill in a model test box by considering the wall friction using carbon rods. The results of test were compared with the theories of Weissenbach and VS Army Code and also with the results of the numerical analysis using finite difference method which introduces Mohr-Coulomb failure hypothesis.

  • PDF

개별요소법을 이용한 터널 안정성 해석에 있어 Barton-Bandis 절리 모델과 Mohr-Coulomb 절리 모델의 비교

  • 이성규;김치환;남기천;박성록;임경호
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2001.03a
    • /
    • pp.109-117
    • /
    • 2001
  • 불연속체 해석을 이용하여 터널 안정성 해석을 수행할 경우 해석 결과는 절리 모델의 선택에 따라 달라진다. 따라서 본 연구에서는 개별요소법을 이용한 불연속체 터널 안정성 해석에 있어 BB 모델 적용시의 해석 결과와 MC 모델 적용시의 해석 결과를 비교하였다. 또한 주어진 응력 조건과 터널 형상에 따른 암반의 변형 거동을 규명하기 위하여 불연속체 해석 결과와 연속체 해석 결과를 비교하였다. 연속체 해석결과와 BB 모델을 사용한 불연속체 해석 결과는 변위 및 응력 분포는 비슷한 양상을 보이는 반면, MC 모델을 사용한 불연속체 해석결과는 이와 다른 양상을 보였다. 또한 MC 모델을 사용하여 불연속체 해석을 실시할 경우 절리의 영향을 명시적으로 고려하였음에도 불구하고 연속체 해석 결과에 비해 변위 및 최소 주응력이 더 작게 발생할 수 있음을 확인할 수 있었다. 이는 MC 모델이 실제 절리의 변형거동 특성을 현실적으로 모사할 수 없기 때문에 발생되는 결과이며, 특히 절리면의 전단거동에 무관하게 팽창각을 일정한 상수로 취급하는 MC 모델의 특성으로 인한 결과이다.

  • PDF

Spudcan Design under Combined Load in Southwestern Sea of Korea (복합하중을 고려한 국내 서남해 지반에서의 Spudcan 설계)

  • Yoo, Jinkwon;Park, Duhee;Mandokhail, Saeed-ullah Jan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.10
    • /
    • pp.13-22
    • /
    • 2016
  • An optimized spudcan was designed for the Southwestern Sea, an area mostly comprised of sand and soft clay layers. The spudcan was designed using guidelines by SNAME, ISO, and InSafeJIP, as well as the yield surface for combined loads. The probe test method was applied to define a yield surface used in estimating spudcan stability. Numerical analyses that considered vertical, horizontal, and moment loads in Southwestern Sea resulted in a design of 8 m diameter spudcan. Additionally, the empirical equations suggested by previous studies can estimate a reasonable spudcan bearing capacity at shallow depth. Each yield surface calculated from Mohr Coulomb and Hardening soil model showed different shapes, however the yield surface also grew with increasing spudcan diameter. This yield surface is a useful reference, along with site investigation results and published guidelines, to estimate the stability of a spudcan in the Southwestern Sea.

Centrifugal Modelling on the Displacement Mode of Unpropped Diaphragm Wall with Surcharge (과재하중이 있는 Unpropped Diaphragm Wall의 변위양상에 관한 원심모델링)

  • 허열;이처근;안광국
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.135-145
    • /
    • 2004
  • In this study, the behavior of unpropped diaphragm walls on decomposed granite soil was investigated through centrifugal and numerical modelling. Centrifuge model tests were performed by changing the interval distance of surcharge. Excavation was simulated during the centrifuge tests by operating a solenoid valve that allowed the zinc chloride solution to drain from the excavation. In these tests, ground deformation, wall displacement and bending moment induced by excavation were measured. FLAC program which can be able to apply far most geotechnical problems was used in the numerical analysis. In numerical simulation, Mohr-Coulomb model fur the ground model, an elastic model for diaphragm wall were used for two dimensional plane strain condition. From the results of model tests, failure surface was straight line type, the ground of retained side inside failure line had downward displacement to the direction of the wall, and finally the failure was made by the rotation of the wall. The angle of failure line was about 67 ∼ 74$^{\circ}$, greater than calculated value. The locations of the maximum ground settlement obtained from model tests and analysis results are in good agreements. The displacement of wall and the change of the embedment depth is likely to have linear relationship.

Stress Analysis of Arctic Thaw Settlement with Gas Pipeline using Finite Element Method (유한요소해석을 활용한 극한지 융해침하에 따른 천연가스배관의 응력해석)

  • Kim, Kyung Il;Yeom, Kyu Jung;Kim, Young-Pyo;Kim, Woo Sik;Oh, Kyu Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.78-84
    • /
    • 2014
  • It is important to secure the supply of gas in arctic region which is not developed recently due to depleting of fossil fuel. It is competing in order to secure the arctic region. The need for the occurring the pipeline design in arctic region is essential for development. In this study, we develop the model of thaw settlements for analysis the stress and displacement which applied with pipe in arctic region between $-40^{\circ}C$ to $20^{\circ}C$. The soil was applied with Mohr-coulomb theory and pipe was elasto-plastic method.

Estimation of Pile Tension Loads Induced by Excavation in Singapore Soft Clay Applying a Pile-Plugged Jet Grouted Slab (말뚝-그라우트 슬라브가 적용된 싱가포르 연약지반 굴착 시 말뚝 인장력 산정에 관한 연구)

  • Lee, Seung-Rae;Park, Hyun-Ku;Shim, Jai-Beom;Lim, Seok-San;Shin, Kang-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.9
    • /
    • pp.77-92
    • /
    • 2009
  • In the present paper, a numerical study was carried out for a reasonable and realistic evaluation of tension loads in piles during deep excavation in Singapore soft soil applying pile-plugged jet grouted slab. Based on 2-dimensional finite element analyses using linear elastic-perfectly plastic soil model obeying Mohr-Coulomb failure criterion, effects of pile-plugged jet grouted slab on the stability during excavation were examined, and a parametric study was also conducted to investigate critical influencing parameters in the estimation of reliable pile tension loads. Finally, based on the Modified Cam-Clay model, pile tension loads were estimated by considering on-going consolidation state of the Singapore clay deposit and the range of critical parameters observed during laboratory tests.

Stability Analysis of a Jointed Rock Slope with the Barton-Bandis Joint Constitute Model Using UDEC (Barton-Bandis joint model을 이용한 절리 암반 사면의 안정성 해석)

  • 최성웅;정소걸
    • Tunnel and Underground Space
    • /
    • v.9 no.2
    • /
    • pp.141-148
    • /
    • 1999
  • Distinct element simulation in jointed rock masses is largely dependent upon the joint constitutive equation used. This paper describes the differences between the Barton-Bandits (BB) and the Mohr-Coulomb (MC) joint constitutive models for the stability analysis of the jointed rock slopes. The BB model, which allows the modelling of the dilation accompanying shear, predicts results very similar to the present condition of slopes. Consequently the 10 cm thick shotcrete was proposed for the reinforcement of those slopes. The MC model, however, in which the dilation angle is constant, is relatively insensitive to the behaviors of joints.

  • PDF

A Study on Design of Support for Cavern in Jointed Rock Mass Using Block Reaction Curve (블록반응곡선을 이용한 불연속 암반내 공동에 대한 지보설계에 관한 연구)

  • 이영주;이희근
    • Tunnel and Underground Space
    • /
    • v.5 no.1
    • /
    • pp.11-21
    • /
    • 1995
  • 일반적으로 NATM공법에서 지보의 설계는 암반반응곡선의 개념을 통해 수행된다. 그러나 암반반응곡선은 암질이 좋고 과지압에 의한 문제가 심각하지 않은 지역에 적용되며, 따라서 주로 불연속면에 의해 암반의 거동이 영향을 받는 지역에서는 시공과정에 직접 적용하기가 힘들다. 본 연구에서는 암반 블록에 대한 블록반응곡선을 연구하여, 블록반응곡선상에서 지보를 설계하였다. 각각의 차분시각에서의 변위와 응력을 얻기위해서 개별요소 프로그램인 UDEC을 사용하였다. 블록은 Mohr-Coulomb 모델이며, 불연속면은 Barton-Bandis 모델이다. 블록과 불연속면의 물성은 실험실 실험을 통하여 구하였다. 블록반응곡선을 이용한 지보설계과정을 이해하기 위하여 간단한 모델분석을 실시하였다. 동일한 형상의 키블록이 공동의 천장, 측벽, 바닥에 존재할 경우, 각 블록의 안정성 판단 및 지보의 설계를 실시하였다. 또한 초기지압의 영향을 알아보기 위하여, 측압계수(K)를 달리하여 해석해보았다. 현재 건설중인 공동에 대한 안정성 판단 및 지보설계를 블록반응곡선을 이용하여 설계하였다.

  • PDF

On the prediction of global first-year ice loads (1년생 빙맥 하중 추정 모델)

  • Rim, Chae-Whan
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.144-152
    • /
    • 1997
  • 본 논문에서는 1년생 빙맥에 의하여 해양구조물에 작용하는 하중을 추정할 수 있는 모델을 제시하였다. 1년생 빙맥을 수면하부(keel), 수면상부(sail), 경화층(consolidated layer)의 3부분으로 나누어 각 부분에 의한 하중을 추정할 수 있는 방법을 논의하였다. 수면하부는 얼음조각(ice rubble)이 층으로 쌓여져 형성된 것이므로 수면하부에 의한 하중추정을 할 때 얼음조각을 선형 Mohr-Coulomb재료로 생각하여 토질역학(soil mechanics)의 이론을 사용하였다. 수면상부에 의한 하중도 토질역학 이론을 이용하여 추정하였으며 경화층에 의한 하중은 Korzhavin식을 이용하여 추정하였다. 제시한 모델을 이용하여 빙맥하중 추정에 미치는 인자들의 영향을 검토하였다.

  • PDF

Numerical Simulation of Dynamic Soil-pile Interaction for Dry Condition Observed in Centrifuge Test (원심모형실험에서 관측된 건조 지반-말뚝 동적 상호작용의 수치 모델링)

  • Kown, Sun-Yong;Kim, Seok-Jung;Yoo, Min-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.4
    • /
    • pp.5-14
    • /
    • 2016
  • Numerical simulation of dynamic soil-pile-structure interaction embedded in a dry sand was carried out. 3D model of the dynamic centrifuge model tests was formulated in a time domain to consider nonlinear behavior of soil using the finite difference method program, FLAC3D. As a modeling methodology, Mohr-Coulomb criteria was adopted as soil constitutive model. Soil nonlinearity was considered by adopting the hysteretic damping model, and an interface model which can simulate separation and slip between soil and pile was adopted. Simplified continuum modeling (Kim et al., 2012) was used as boundary condition to reduce analysis time. Calibration process for numerical modeling results and test results was performed through the parametric study. Verification process was then performed by comparing numerical modeling results with another test results. Based on the calibration and validation procedure, it is identified that proposed modeling method can properly simulate dynamic behavior of soil-pile system in dry condition.