• Title/Summary/Keyword: Module Temperature

Search Result 1,228, Processing Time 0.027 seconds

Study on Surface Temperature Change of PV Module Installed on Green Roof System and Non-green Roof System (옥상녹화와 비 옥상녹화 평지붕에 설치 된 PV모듈의 표면온도 변화 고찰)

  • Yoo, Dong-Chul;Lee, Eung-Jik;Lee, Doo-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.214-219
    • /
    • 2011
  • Today, various activities to save energy are being conducted around the world. Even in our country, carbon reduction policy is being conducted for low carbon green growth and with this movement, effort to replace energy sources by recognizing the problems on environment pollution and resource exhaustion due to the indiscrete usage of fossil fuel is being made. Therefore, active study on renewable energy is in progress as part of effort to replace the energy supply through fossil fuel and solar ray industry has rapidly developed receiving big strength of renewable energy policies. The conclusion of this study measuring the surface temperature change of single crystal and polycrystalline PV module in green roof system and non-green roof system aspect are as follows. There was approximately $4^{\circ}C$ difference in PV module temperature in green roof system and non-green roof system aspect and this has the characteristic to decrease 0.5% when the temperature rises by $1^{\circ}C$ when the front side of the module is $20^{\circ}C$ higher than the surrounding air temperature following the characteristic of solar cells. It can be concluded that PV efficiency will be come better when it is $4^{\circ}C$ lower. Also, in result of temperature measurement of the module back side, there was $5^{\circ}C$ difference of PV module installed on the PV module back side and green roof system side on the 5th, $3^{\circ}C$ on the 4th, $2^{\circ}C$ on the 5th to show decreasing temperature difference as the air temperature dropped, but is judged that there will be higher temperature difference due to the evapotranspiration latent heat effect of green roof system floor side as the temperature rises. Based on this data, it is intended to be used as basic reference to maximize efficiency by applying green roof system and PV system when building non-green roof system flat roof.

  • PDF

Characteristics of Photovoltaic I-V According to the Module Temperature

  • Lee, Ying;Choi, Yong-Sung;Zhang, You-Sai;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2101.1_2102.1
    • /
    • 2009
  • Solar energy is an extreme intermittent and inconstant energy source. This paper presents the analysis of photovoltaic I-V characteristics according to the module temperature. It shows that the result of the relationship between DC current and the module temperature of solar cell will be effects by the increasing irradiation.

  • PDF

Peeling Behavior of Backsheet according to Surface Temperature of Photovoltaic Module (태양광 모듈 표면 온도 제어에 따른 백시트 박리 거동)

  • Kim, Jeong-Hun;Lee, Jun-Kyu;Ahn, Young-Soo;Yeo, Jeong-Gu;Lee, Jin-Seok;Kang, Gi-Hwan;Cho, Churl-Hee
    • Korean Journal of Materials Research
    • /
    • v.29 no.11
    • /
    • pp.703-708
    • /
    • 2019
  • In this study, we investigate the relationship between the peeling behavior of the backsheet of a photovoltaic(PV) module and its surface temperature in order facilitate removal of the backsheet from the PV module. At low temperatures, the backsheet does not peel off whereas, at high temperatures, part of the backsheet remains on the surface of the PV module after the peeling process. The backsheet material remaining on the surface of the PV module is confirmed by X-ray diffraction(XRD) analysis to be poly-ethylene(PE). Differential scanning calorimetry(DSC) is also performed to investigate the interfacial characteristics of the layers of the PV module. In particular, DSC provides the melting temperature($T_m$) of laminated ethylene vinyl acetate(EVA) and of the backsheet on the PV module. It is found that the backsheet does not peel off below the $T_m$ of ethylene of EVA, while the PE layer of the backsheet remains on the surface of the PV module above the $T_m$ of the PE. Thus, the backsheet is best removed at a temperature between the $T_m$ of ethylene and that of PE layer.

Thermal Analysis for Improvement of Heat Dissipation Performance of the Rail Anchoring Failure Detection Module (레일 체결구 결함 검측 모듈의 방열성능 개선을 위한 열 해석)

  • Chae, Won kyu;Park, Young;Kwan, Sam young;Lee, Jaehyeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.125-130
    • /
    • 2016
  • In this paper, various heat dissipation designs for a rail anchoring failure detection module were investigated by a thermal flow analysis. For the detection module with the heat dissipation design on the overall housing surface, an average temperature inside the module was lowered by $25^{\circ}C$ when compared to no heat dissipation design. In addition, an internal heat-flow blocking layer and an heat conduction layer inserted between the LED module and housing case were effective in reducing the temperature in the rail anchoring failure detection, which has a limited space for installation and little air flow. Especially, the temperature near LED module decreased below $55^{\circ}C$ when the optimal heat dissipation design was applied.

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

Output Power Characteristics According to Temperature for Photovoltaic Systems (태양광 발전시스템의 온도에 따른 출력전력 특성)

  • Park, Chul-Woong;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.186-188
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation and module temperature from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation, module temperature of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. The results of this thesis can be summarized as follows. As output power characteristics according to a temperature range of 10$\sim$50[], output power was increased with an increase in temperature. Since output power increases with temperature increase, the result corresponds well to the related equation on temperature and output power.

  • PDF

Numerical Analysis on the Characteristic of Thermal Distribution for High Temperature Operating Battery Module (고온 작동형 전지모듈 온도분포 특성에 관한 수치해석)

  • Yi, Chung Seob;Lee, Byung Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.102-108
    • /
    • 2013
  • In this study, the experiment result and numerical analysis on temperature distribution of a secondary battery module for high temperature operation type were compared. Because experimental battery has been in danger of explosions, experiment on temperature distribution was carried out using dummy batteries. Study on NAS battery module, which is secondary battery of high temperature operation type, is as follows ; Test result showed that battery's temperature is in steady state uniformly after 8 hours in each section. It is similar to experimental result for temperature distribution from the result of numerical analysis, and it takes about 8.5 hours to the $300^{\circ}C$.

A Study on the Temperature Distribution Characteristics of NAS Battery Module (NAS 전지 모듈의 온도 분포 특성에 관한 연구)

  • Heo, Doo-Sang;Yi, Chung-Seob;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2012
  • This paper addresses the issue of Renewable Energy for Electricity Storage device is one of the NAS (Sodium-Sulfur) battery will be about the module. For safety reasons, not the actual battery cells using a dummy cell in the module's operating temperature setting to examine the characteristics of the insulation vacuum of the wall temperature and external temperature changes measured over time. Upper and lower boundaries of the wall vacuum insulation characteristics cotton C intervals over time, average $5^{\circ}C$, but the temperature is rising, 4C section with little temperature change did not occur. On the other hand, about $3^{\circ}C$ in section 4D, and it was confirmed that the temperature rises. Wall vacuum insulation characteristics over time to look at the experiments and measurements are described.

A Study on the Performance of 100 W Thermoelectric Power Generation Module for Solar Hot Water System (태양열 온수 시스템에 적용 가능한 100 W급 열전발전 모듈 성능에 관한 연구)

  • Seo, Ho-Young;Lee, Kyung-Won;Yoon, Jeong-Hun;Lee, Soon-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.21-32
    • /
    • 2019
  • Solar hot water system produces hot water using solar energy. If it is not used effectively, overheating occurs during the summer. Therefore, a lot of research is being done to solve this. This study develops thermoelectric power module applicable to solar hot water system. A thermoelectric material can directly convert thermal energy into electrical energy without additional power generation devices. If there is a temperature difference between high and low temperature, it generate power by Seebeck effect. The thermoelectric module generates electricity using temperature differences through the heat exchange of hot and cold water. The water used for cooling is heated and stored as hot water as it passes through the module. It can prevent overheating of Solar hot water system while producing power. The thermoelectric module consists of one absorption and two radiation part. There path is designed in the form of a water jacket. As a result, a temperature of the absorption part was $134.2^{\circ}C$ and the radiation part was $48.6^{\circ}C$. The temperature difference between the absorption and radiation was $85.6^{\circ}C$. Also, The Thermoelectric module produced about 122 W of irradiation at $708W/m^2$. At this time, power generation efficiency was 2.62% and hot water conversion efficiency was 62.46%.

Fabrication of NTC thermistor embedded Miniature Thermoelectric Cooling Module for Temperature Control (NTC 써미스터가 내장된 항온 제어용 소형 열전 냉각 모듈 제조)

  • Park J. W.;Choi J. C.;Hwang C. W.;Choi S. C.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.83-89
    • /
    • 2004
  • NTC thermistor embedded miniature thermoelectric module was fabricated for the precise temperature control of optical communication device such as laser diode (LD). The miniature thermoelectric module ($7.2 mm{\times}9 mm{\times}2.2 mm$) consists of 21 BiTe thermoelectric couples, the operating temperature is precisely controlled by embedded thermistor with quick response. The figure-of-merit (Z), maximum temperature difference (${\Delta}T_{max}$), maximum cooling capacity ($Q_{max}$) of the miniature thermoelectric module were $2.5{\times}10^{-3}$/K, 72 K, 2.2 W respectively and temperature could be controlled in range of ${\pm}0.1^{\circ}C$ accuracy in air. The fabricated miniature thermoelectric module is suitable for applications of the optical communication packaging.

  • PDF