• Title/Summary/Keyword: Modified rate

Search Result 2,766, Processing Time 0.038 seconds

Study on Correlation of Droplet Flow Rate and Film Boiling Heat Transfer in Spray Cooling (액적 유량과 분무냉각 막비등 열전달의 상관관계에 관한 연구)

  • Yun, Seung-Min;Kim, Yeung-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.335-340
    • /
    • 2007
  • A new correlation between the Nusselt number based on modified heat transfer coefficient and Reynold number based on droplet-flow-rate was developed for the experimental data. The modified heat transfer coefficient was defined as ratio of wall heat flux to droplet subcooling. In the previous reports, the local heat flux of spray cooling in the film boiling region was experimentally investigated for the water spray region of $D_{max} = 0.0007{\sim}0.03m^3/(m^2s)$ . In the region near the stagnation point of spray flow, a new heat transfer correlation is recommended which shows good predictions for the water spray region of $D_x{\le}0.01m^3/(m^2s)$.

ANALYSIS OF THE MMPP/G/1/K QUEUE WITH A MODIFIED STATE-DEPENDENT SERVICE RATE

  • Choi, Doo Il;Kim, Bokeun;Lim, Dae-Eun
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.18 no.4
    • /
    • pp.295-304
    • /
    • 2014
  • We analyze theMMPP/G/1/K queue with a modified state-dependent service rate. The service time of customers upon service initiation is changed if the number of customers in the system reaches a threshold. Then, the changed service time is continued until the system becomes empty completely, and this process is repeated. We analyze this system using an embedded Markov chain and a supplementary variable method, and present the queue length distributions at a customer's departure epochs and then at an arbitrary time.

Analysis of Dynamic Behavior in GMAW System (GMA용접 시스템의 동적 거동에 대한 해석)

  • 이재영;최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.41-48
    • /
    • 2000
  • Dynamic behaviors of the GMAW system are simulated using the short-circuit transfer model and the characteristic equations fir the power supply, wire system and arc. The conventional wire equation, which relates the rate change of the wire extension to the wire feed rate and melting rate, is modified to include effects of the molten drop attached at the wire tip. The modified wire equation describes behaviors of the GMAW system more precisely and provides information about the initial bridge volume for short-circuit transfer. The proposed short-circuit model predicts the variation of parameters such as the current, voltage, short-circuit frequency and time considering the effects of the surface tension and electromagnetic force due to current. The calculated results are in broad agreements with the experimental results under the argon shielding condition.

  • PDF

Development of New High Temperature Plasma Sources for Spectrochemical Analysis: Multivariate Optimization by the Modified Sequential Simplex Method

  • Lee, Gae-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.2
    • /
    • pp.275-281
    • /
    • 1993
  • The new high temperature plasma source for spectrochemical analysis has been developed and characterized. In the development of new high temperature plasma sources for atomic emission spectrocopy, optimization of experimental variables is necessary to achieve the best analytical results. By means of a modified sequential simplex optimization method, six experimental variables were optimized. The line-to-background (L/B) ratio for Ca(II) at 393.37 nm was used as measure of the response function. The optimal experimental conditions were found to be at a current of 27.8 A, a plasma length of 28.8 mm, a sample uptake rate of 1.3 ml/min, a sample carrier gas flow rate of 0.7 ml/min, a plasma gas flow rate of 4.9 l/min, and an observation height of 6.4 mm above the top quartz tube.

Development of Finite Element Ductile Tearing Simulation Model Considering Strain Rate Effect (변형률 속도를 고려한 유한요소 기반 연성 찢김 해석 기법 개발)

  • Nam, Hyun Suk;Kim, Ji Soo;Kim, Jin Weon;Kim, Yun Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.167-173
    • /
    • 2016
  • This paper proposes ductile failure simulation under high strain rate conditions using finite element (FE) analyses. In order to simulate a cracked component under a high strain rate condition, this paper applies the stress-modified fracture strain model combined with the Johnson/Cook model. The stress-modified fracture strain model determines the incremental damage in terms of stress triaxiality (${\sigma}_m/{\sigma}_e$) and fracture strain (${\varepsilon}_f$) for a dimple fracture using the tensile test results. To validate the stress-modified fracture strain model under dynamic loading conditions, the parameters are calibrated using the tensile test results under various strain rates and the fracture toughness test results under quasi-static conditions. The calibrated damage model predicts the CT test results under a high strain rate. The simulated results were then compared with the experimental data.

Effect of Loading Rate in the Operation of DEPHANOX and Modified-DEPHANOX Processes (유입부하가 DEPHANOX 및 Modified-DEPHANOX 공정에 미치는 영향)

  • Ryu, Hong-Duck;Min, Kyung-Kook;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • This study was initiated to evaluate the efficiencies of DEPHANOX and Modified-DEPHANOX, which were devoloped to enhance nitrogen removal efficiency in municipal wastewater treatment. In the results, removal efficiency of organic matters was not affected much by increased loading rate of organic matters which is contained in influent. The nitrogen removal efficiencies according to the loading rate of influent TN was decreased drastically in conditions of over $0.2kg/m^3{\cdot}day$, which is T-N loading rate, and the DEPHANOX process was affected more sensitively than the M-DEPHANOX was. When the temperature was altered from $25^{\circ}C$ to $16^{\circ}C$ at HRT 6hrs, the removal efficiency of ammonia nitrogen was still over 90% and it was concluded that both DEPHANOX and M-DEPHANOX were strong enough to endure temperature variation. Moreover, both processes showed over 90% in ammonia removal efficiencies in over HRT 5hrs, so it was concluded that they were strong in HRT variation. M-DEPHANOX process showed a higher value than DEPHANOX did in T-N removal efficiency to the extent of 4~21 %, which resulted from differency of denitrification rates and the biosorption efficiency of organic matter in both processes. In the condition of HRT less than 4hrs, concentrations of ammonia nitrogen contained in effluents and nitrification reactors, might be sensitively affected by biosorption efficiency of organic matters in first separation tank. In the effect of effluent nitrate concentration in phosphorus removal, the more effluent nitrate concentration was decreased, the more phosphorus removal efficiency was increased. This result is related to the decrease of concentration of effluent nitrate which resulted from nitrification inhibition by decreased HRT.

Kinetic Analysis of Rate Limiting Step in the Metabolic Process -[Part I.] A Modified Emzymatic Method- (대사과정(代謝過程)에 있어서 율속단계(律速段階)의 속도론적(速度論的) 해석(解析) -[제1보(第一報)] 수정된 효소적 방법에 대하여-)

  • Shin, Kui-Nam;Koh, Ik-Bai
    • Applied Biological Chemistry
    • /
    • v.19 no.3
    • /
    • pp.162-171
    • /
    • 1976
  • The determination of rate limiting step in the metabolic process is of great importance to understand the metabolic properties. In this paper the authors propose a modified enzymatic method instead of thermodynamic method. This method is based on the assumption that the over-all rate increment would be larger than by any other steps to which the individual enzyme are added respectively, provided that the enzyme participated in the rate limiting step is added to the reactions composed of n steps of metabolic process with which n kind of enymes are concerned. The present paper deals with analysis and discussion about some factors having influence on the proposed process, mainly about the metabolic process constituted with homogeneous steps. The results show that the determination of rate limiting step by a modified enzymatic method is feasible, provided that some restrictions are added in any type of mechanisms.

  • PDF

Electrochemistry and Determination of 1-Naphthylacetic Acid Using an Acetylene Black Film Modified Electrode

  • Huang, Wensheng;Qu, Wanyun;Zhu, Dazhai
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.7
    • /
    • pp.1323-1325
    • /
    • 2008
  • The acetylene black (AB) was dispersed into water in the presence of dihexadecyl hydrogen phosphate (DHP) via ultrasonication, resulting in a stable and well-distributed AB/DHP suspension. After evaporation of water, an AB/DHP composite film-modified electrode was prepared. The electrochemical responses of $K_3$[Fe$(CN)_6$] at the unmodified electrode, DHP film-modified electrode and AB/DHP film-modified electrode were investigated. It is found that the AB/DHP film-modified electrode possesses larger surface area and electron transfer rate constant. Furthermore, the electrochemical behaviors of 1-naphthylacetic acid (NAA) were examined. At the AB/DHP film-modified electrode, the oxidation peak current of NAA remarkably increases. Based on this, a sensitive and convenient electrochemical method was proposed for the determination of NAA. The linear range is in the range from $4.0 {\times} 10^{-8}\;to\;5.0 {\times} 10^{-6}$ mol $L^{-1}$, and the detection limit is $1.0 {\times} 10^{-8}$ mol $L^{-1}$. Finally, this new sensing method was employed to determine NAA in several soil samples.

The Treatment of Osmidrosis Axillae by Use of Modified Skoog's Method (Skoog씨 변법을 이용한 액취증의 치료)

  • Yim, Young-Min;Choi, Jong Woo;Kim, Gi Ho
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.245-249
    • /
    • 2005
  • Various surgical procedures have been described for treating osmidrosis axillare. Elimination of the apocrine glands is prime goal. Optimal operative procedure is characterized as follows: minimal axillary scar(which has cosmetic merits), less complications such as hematoma and seroma, short and less painful recuperating period, minimal damage to the skin and low recurrence rate. Three types of incision technique in subdermal shaving method have beeb commoly used. First, single incision method has an advantage of minimal scarring but more recurrence due to incomplete removal of apocrine glands may occur. Second, double incision technique(Bipedicled flap) has advantages of complete excision, low recurrence rate and relatively minimal scarring, but it could cause frequent necrosis of skin and folding of skin flap. Skoog's method is the third method, which makes four flaps by offset cruciate incisions. It is a better technique in aspect of complete excision of apocrine glands and low recurrence rate but has disadvantages such as development of hypertrophic scar or scar contracture in the line that lies perpendicular to natural axillary skin crease. We used a modified procedure which has shorter length in vertical and transverse incision compared with the classic Skoog's method. We dissected further subcutaneous tissue through the diamond-shaped incision and utilize wide operation field that provide adequate excision of subdermal tissue and proper hemostasis. Between 1999 and 2004, we operated 160 osmidrosis axillare in 80 patients in this technique. Most patients obtained satisfactory result with very low complications. Hematoma or seroma 3.1% Infection 0.6% Partial wound disruption 10% Recurrence 1.2%. Modified Skoog's method for treating osmidrosis axillae could be a optimal technique providing wide operation field for adequate excision of apocrine glands and proper hemostasis and leaving relatively inconspicuous scar and low incidence of scar contracture.

Electrochemical Characteristics at Copolymeric film Electrodes of [Ru(v-bpy)$_3$]$^{2+}$ and Vinylbenzoic Acid Modified with Dopamine (Dopamine으로 수식된 [Ru(v-bpy)$_3$$^{2+}$와 Vinylbenzoic Acid의 공중합 피막 전극의 전기화학 특성)

  • 차성극;박유철;임태곤
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.782-788
    • /
    • 2001
  • The $[Ru(v-bpy)_3]^{2+}$ and vinylbenzoic acid (vba) were electrochemically copolymerized to afford electrodes modified with dopamine to study their properties such as electropolymerization rate, redox process, and electron transfer. The optimum mole ratio of the monomers was 5:2, which gave $1.84{ imes}10^{-2}s^{-1}$ of rate constant for first order reaction, while the ratio of the substances on the copolymeric film produced was 5:1.68. The formal potential produced from the hydroquinone=quinone+$2H^+2e^-$reaction at the electrode of GC/p- $[Ru(v-bpy)_3]^{2+}$/vba-dopamine was 0.17 V in phosphate buffer (pH=7.10). The electrocatalytic rate was $2.58{ imes}10^5cms^{-1}$;2.41 times faster than that of non-modified one. The mass change measured by EQCM was $3.28{ imes}10^3$$gmol^{-1}$ which is larger than that of non-modified one.

  • PDF