• Title/Summary/Keyword: Modified electrodes

Search Result 247, Processing Time 0.022 seconds

Poly-3,4-dihydroxybenzoic Acid Film Electrodes Modified with Dopamine for Determination of Ti(IV) Ions (도파민으로 수식된 3,4-dihydroxybenzoic acid 고분자 피막전극을 이용한 Ti(IV)이온의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.130-133
    • /
    • 2003
  • 3,4-dihydroxybenzoic acid(3,4-DHBA) was electropolymerized on glassy carbon electrode to give the GC/p-3,4-DHBA type electrode which was modified with dopamine by the help of 1-(3-dimethylaminopropyl)-3-ethyl carbodiimide hydrochloride(EDC) acting as a coupling agent. The carboxylic sites on the polymeric surface of p-3,4-DHBA and mine group at the dopamine gave a QCA(Au)/p-3,4-DHBA-dopamine type of modified electrodes. The o-quinone moieties at the electrode surface exhibited high selectivity to titanium ions in solution. The redox process of the electrode is hydroquinone : quinone +$2H^+2e^-$, which had two strong and two weak pairs of peaks at CV. The modified electrode can deposit Ti(IV) ions as much as $4.13\times10^{-5}gcm^{-2}$. The calibration curve of the electrodes, log of the surface coverage-normalized redox response vs log[Ti], exhibited an excellent correlation$(r{\geq}0.997)$ for titanium concentrations ranging from $5.25\times10^{-4}\;to\;5.25\tiems10^{-8}M.$.

Electrical Recognition of Label-Free Oligonucleotides upon Streptavidin-Modified Electrode Surfaces

  • Park, Jong-Wan;Jung, Ho-Sub;Lee, Hea-Yeon;Kawai, Tomoji
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.6
    • /
    • pp.505-509
    • /
    • 2005
  • For the purpose of developing a direct label-free electrochemical detection system, we have systematically investigated the electrochemical signatures of each step in the preparation procedure, from a bare gold electrode to the hybridization of label-free complementary DNA, for the streptavidin-modified electrode. For the purpose of this investigation, we obtained the following pertinent data; cyclic voltammogram measurements, electrochemical impedance spectra and square wave voltammogram measurements, in $Fe(CN)_6^{3-}/Fe(CN)_6^{4-}$ solution (which was utilized as the electron transfer redox mediator). The oligonucleotide molecules on the streptavidin-modified electrodes exhibited intrinsic redox activity in the ferrocyanide-mediated electrochemical measurements. Furthermore, the investigation of electrochemical electron transfer, according to the sequence of oligonucleotide molecules, was also undertaken. This work demonstrates that direct label-free oligonucleotide electrical recognition, based on biofunctional streptavidin-modified gold electrodes, could lead to the development of a new biosensor protocol for the expansion of rapid, cost-effective detection systems.

Electrochemical Determination of Dopamine Based on Carbon Nanotube-Sol-Gel Titania-Nafion Composite Film Modified Electrode

  • Park, Ji-Ae;Kim, Byung-Kun;Choi, Han-Nim;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3123-3127
    • /
    • 2010
  • A highly sensitive electrochemical detection method for dopamine (DA) has been developed by relying on a multiwalled carbon nanotube (CNT)-sol-gel titania-Nafion composite film modified glassy carbon (GC) electrode. The CNT-titania-Nafion/GC electrode exhibited excellent electrocatalytic activity towards DA. Therefore, the CNT-titania-Nafion/GC electrode showed improved voltammetric and amperometric responses for DA compared to those obtained with both titania-Nafion/GC and Nafion/GC electrodes. The CNT-titania-Nafion/GC electrode gave a linear response ($R^2$ = 0.999) for DA from $0.5\;{\mu}M$ to 0.5 mM with a detection limit (S/N = 3) of $0.1\;{\mu}M$ and a good sensitivity of 150 mA/M while other electrodes such as CNT-Nafion/GC, titania-Nafion/GC, and a bare GC gave a sensitivity of 89, 39, and 36 mA/M, respectively. Besides, the CNT-titania-Nafion/GC electrode displayed very fast response time within 2 s. The modified electrode showed good selectivity against ascorbic acid. The modified electrode showed good stability and reproducibility. The CNT-titania-Nafion/GC electrode was applied to the determination of DA in urine and serum samples.

Vt Close Curve Analysis for Improving Address Discharge Characteristics in Open Dielectric Structure of AC PDP (플라즈마 디스플레이의 개방형 유전체 구조에서 기입방전특성을 향상시키기 위한 Vt 폐곡선 분석)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.179-184
    • /
    • 2014
  • The discharge characteristics of an open dielectric structure were investigated, especially such as a firing voltage and related wall voltage, compared with conventional panel structure based on the Vt close curve measurement in AC plasma display panel. While the front panel of the conventional structure in AC plasma display panel was composed of the glass, electrodes, and dielectric, the open dielectric structure could easily produce the discharge between the scan and the sustain electrodes by erasing the dielectric layer between two electrodes. As the open dielectric structure differ from the conventional structure, various problems were produced when driving with the conventional driving waveform. Especially, due to the changes in the discharge firing characteristics of the open dielectric structure between the scan and the sustain electrodes on the front panel, the conventional reset waveform including the address waveform needed to be modified. In this study, the Vt close curves were measured to compare the discharge firing voltages on three electrodes in the conventional and open dielectric structure and based on the Vt close curve analysis, the modified driving waveform suitable for the open dielectric structure was proposed.

Actuating Characteristics of a Piezoceramic fiber Composite Actuator (압전섬유 복합재 엑츄에이터의 거동 특성)

  • Koo, Kun-Hyung;Kim, Cheol
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.53-56
    • /
    • 2001
  • Piezoelectric Fiber Composites with Interdigitated Electrodes (PFCIDE) were previously introduced as an alternative to monolithic wafers with conventional electrodes for applications of structural actuation. This paper is an investigation into the performance improvement of piezoelectric fiber composite actuators by changing the matrix material and actuator shape. This paper presents a modified micro-electromechanical model and numerical analyses of piezoelectric fiber/piezopolymer matrix composite actuator with interdigitated electrodes (PFPMIDE). Numerical analyses show that the shape of the graphite/epoxy composite plate with the PFPMIDE may be controlled by judicious choice of voltages, piezoelectric fiber angles, and elastic tailoring of the composite plate.

  • PDF

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.

Electrocatalytic Oxidation of NADH at Electrodes of Self-assembled Monolayers Modified with Dopamine (도파민으로 수식된 SAMs 전극에서 NADH의 전기촉매에 의한 산화)

  • Cha, Seong-Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.2
    • /
    • pp.151-155
    • /
    • 2004
  • The self-assembled mololayers(SAMs)were prepared with cysteine(cys) and subsequently coupled with dopamine(dopa) containing quinone functionality on the gold modified electrodes. The SAMs annealed in ethanol for 6 hours gave a better shaped cyclic voltammogram which had a 0.28 V of formal potential and same redox potential in 0.1M phosphate buffer(pH=7.10). The electrodes were employed to determine concentration of HADH with the result that calibration curve exhibited an excellent correlation(${\geq}$ 0.993) for the concentrations ranging up to 5.0${\times}10^{-4}$ M.