• Title/Summary/Keyword: Modified Ground

Search Result 557, Processing Time 0.026 seconds

Modelling and packed bed column studies on adsorptive removal of phosphate from aqueous solutions by a mixture of ground burnt patties and red soil

  • Rout, Prangya R.;Dash, Rajesh R.;Bhunia, Puspendu
    • Advances in environmental research
    • /
    • v.3 no.3
    • /
    • pp.231-251
    • /
    • 2014
  • The present study examines the phosphate adsorption potential and behavior of mixture of Ground Burnt Patties (GBP), a solid waste generated from cooking fuel used in earthen stoves and Red Soil (RS), a natural substance in fixed bed column mode operation. The characterization of adsorbent was done by Proton Induced X-ray Emission (PIXE), and Proton Induced ${\gamma}$-ray Emission (PIGE) methods. The FTIR spectroscopy of spent adsorbent reveals the presence of absorbance peak at $1127cm^{-1}$ which appears due to P = O stretching, thus confirming phosphate adsorption. The effects of bed height (10, 15 and 20 cm), flow rate (2.5, 5 and 7.5 mL/min) and initial phosphate concentration (5 and 15 mg/L) on breakthrough curves were explored. Both the breakthrough and exhaustion time increased with increase in bed depth, decrease in flow rate and influent concentration. Thomas model, Yoon-Nelson model and Modified Dose Response model were used to fit the column adsorption data using nonlinear regression analysis while Bed Depth Service Time model followed linear regression analysis under different experimental condition to evaluate model parameters that are useful in scale up of the process. The values of correlation coefficient ($R^2$) and the Sum of Square Error (SSE) revealed the Modified Dose Response model as the best fitted model to the experimental data. The adsorbent mixture responded effectively to the desorption and reusability experiment. The results of this finding advocated that mixture of GBP and RS can be used as a low cost, highly efficient adsorbent for phosphate removal from aqueous solution.

A Study on Review-Level Ground Motion For Seismic Margin Assessment (내진여유도 평가를 위한 부석기준지진동(RLGM) 평가 연구)

  • 연관희;이종림
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.97-104
    • /
    • 2000
  • Evaluating a Review-Level Ground Motion is a key to efficiently perform Seismic Margin Assessment of nuclear power plants whose purpose is to determine a ground motion level for which a plant has high-confidence-of-a-low-probability of seismic-induced core damage and to identify any weaker-link components. In this study a method to obtain RLGMs is reviewed which is recommended by Electric Power Research Institute and implemented to be applied to Limerick site in eastern and central U. S as a case study. This method provides reasonable and site-specific RLGMs as minimum required plant HCLPF for SMA that meet a target mean seismic core-damage frequency based on seismic hazard results and generic values of uncertainty and randomness parameters of the core-damage fragility curves. In addition high-frequency RLGM is justifiably modified to reflect the increased seismic capacity of high-frequency components and spatial variation and incoherence of input ground motion on a basemat of large structures by establishing a method to obtain high0-frequency reduction factors according to EPRI guidelines.

  • PDF

Hybrid Planar Inverted-F Antenna with a T-Shaped Slot on the Ground Plane

  • Jeon, Sin-Hyung;Choi, Hyeng-Cheul;Kim, Hyeong-Dong
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.616-618
    • /
    • 2009
  • In this letter, a novel hybrid planar inverted-F antenna (PIFA) with a T-shaped slot on the ground plane is proposed. The loop structure formed by the feed line and shorting pin can be operated as a series and shunt inductance for the PIFA and the T-shaped slot antenna, respectively. The PIFA operates at a frequency of 1.75 GHz, while the T-shaped slot on the ground plane operates at 2.4 GHz by the same voltage feeding source. The height of the PIFA is 6.5 mm, and the size of an upper patch is designed to be 30 mm${\times}$16 mm. The measured relative impedance bandwidth of the PIFA and the T-shaped slot are about 12% and 21%, respectively. In addition, good antenna performance was achieved.

Behavior of SCP Improved Ground with Installation of Sheet Pile (Sheet Pile 설치에 따른 SCP개량지반의 거동)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.211-218
    • /
    • 2002
  • The paper is to show the behavior of composit ground which is installed with sheet pile in soft soil improved by sand compaction pile. The results of load-settlement relationship, earth pressure, stress concentration characteristics, and final water content were obtained by centrifuge model test. Two cases of tests, installation of sheet pile on the corner and both side of the loading plate for the improved SCP ground which was designed twice of the footing width, were performed for the tests under the vertical and horizontal loading and both side of corner. Finite element program(CRISP) for sand compaction pile using elasto-plastic model and numerical analysis for soft soil using modified cam-clay constitutive equation were compared and analized with the results of model tests. The result of analysis show the increased bearing capacity of soil after, SCP and sheet pile was installed.

  • PDF

Predicting ground-based damage states from windstorms using remote-sensing imagery

  • Brown, Tanya M.;Liang, Daan;Womble, J. Arn
    • Wind and Structures
    • /
    • v.15 no.5
    • /
    • pp.369-383
    • /
    • 2012
  • Researchers have recently begun using high spatial resolution remote-sensing data, which are automatically captured and georeferenced, to assess damage following natural and man-made disasters, in addition to, or instead of employing the older methods of walking house-to-house for surveys, or photographing individual buildings from an airplane. This research establishes quantitative relationships between the damage states observed at ground-level, and those observed from space using high spatial resolution remote-sensing data, for windstorms, for individual site-built one- or two-family residences (FR12). "Degrees of Damage" (DOD) from the Enhanced Fujita (EF) Scale were determined for ground-based damage states; damage states were also assigned for remote-sensing imagery, using a modified version of Womble's Remote-Sensing (RS) Damage Scale. The preliminary developed model can be used to predict the ground-level damage state using remote-sensing imagery, which could significantly lessen the time and expense required to assess the damage following a windstorm.

Development of a Ground Speed Monitoring System for Aerial Application (항공방제용 지면속도 감시장치의 개발)

  • 구영모;알빈워맥
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.233-240
    • /
    • 2000
  • A commercially available Doppler radar was modified and evaluated for on-board monitoring of ground speed. The radar output was corrected for pitch angle of aircraft based on the output of an electrolytic tilt sensor. The effects of aircraft speed, height and mounting angle on error in the ground speed were evaluated. The speed error decreased with an increase of the mounting angle since the radar contact angle with respect to the ground approached to the mounting angle. The error increased with an increase of the nominal aircraft speed. The altitude insignificantly affected the speed error. The Doppler radar provided acceptable percent errors within 5% in most measurements. The error can be reduced within ${\pm}$1.5% by increasing the mounting angle ($43^{\circ}$). The error of -3.8% at the mounting angle of $29^{\circ}$could be reduced by adjusting the mounting angle with respect to the radar contact angle.

  • PDF

Seismic Wave Analysis of Buried Pipelines Using Ground Strain Model (지반변형률 모형을 이용한 매설관의 지진파 해석)

  • 김문겸
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.91-98
    • /
    • 1999
  • In this study a modified ground strain model is developed for an equivalent earthquake load and is applied to the seismic analysis of buried pipelines, The ground strain can be obtained using the ratio of a maximum ground velocity to a wave propagation velocity. To reflect soil conditions and seismic characteristics the wave propagation velocity is evaluated by a proposed dispersion curve based on wave energy distribution. In order to verify the procedures the observed earthquake data and the results of this study are compared. For the application of an equivalent earthquake load to the seismic analysis the buried pipelines are modeled using the beam theory. the results of the analyses are compared with those of a dynamic analysis code and those obtained from the response displacement method. Finally various parametric studies considering different soil conditions and seismic loads are examined.

  • PDF

Behavior of Geogrid-Reinforced Soil with Cyclic plate Load Test (반복 평판재하시험을 통한 지오그리드 보강지반의 거동 특성)

  • 신은철;김두환;이상조;이규진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.285-292
    • /
    • 1999
  • The cyclic plate load test were peformed to determine the behavior of reinforced soft ground with multiple layers of geogrid. Five series of test were conducted with varying the soil profile conditions which including the ground level, type of soil, and the thickness of each soil layer. The plate load test equipment was slightly modified to apply the cyclic load. Based on the cyclic plate load test results, the bearing capacity ratio(BCR), subbase modules, shear modules, the elastic rebound ratio, and reinforcing parameters are presented.

  • PDF

An Experimental Study on the Compressive Strength Development of antiwashout underwater Concrete with Blended Ratio of Finely Ground Granulated Blast Furnace Slag (고로슬래그 미분말 치환율에 따른 수중불분리성 콘크리트의 압축강도 발현에 관한 실험적 연구)

  • 김명식;이환우;양영인;정해동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.57-61
    • /
    • 2000
  • This experimental study was carried out to estmate the effects of mixing dosage rate and blain on the compressive strength properties of antiwashout underwater concrete admixed with finely ground granulated blast furnace slag. The experimental parameters are slag contents(0, 20, 30, 40, 50, 60%). As a result the compressive strength have a high correlation with slag blended ratio. Thus, it is possible to calculate the modulus of modified age using compressive strength of antiwashout underwater concrete blended with slag.

  • PDF

Impedance Calculation for Electric Railway System using modified Carson's Method (Modified Carson's Method를 이용한 전차선로의 Impedance 계산)

  • LEE Chunbae;KIM Wanggon;LEE Jongwoo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1403-1405
    • /
    • 2004
  • The method proposed by Carson contains indefinite complex integral which simulates earth return current. Although the Carson solution is proposed with power series, the solution is limited and valid at special range of frequency. We proposed a simplified Carson solution by modelling earth current path analytical method using ground transmission line return current. In this paper, we studied on trying to find the equivalent distance for earth current return path.

  • PDF